Smartguard Use in Real Life : a Longitudinal Study in Patients With Type 1 Diabetes
NCT03047486 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2026-04-02
Summary
The reference treatment of the type 1 diabetes is intensified insulin therapy by insulin pump. The CGM (continuous glucose monitoring) is a technology available for a decade, which allows the continuous measure of interstitial glucose rate. The results are available in real time to the user, who can so use them to optimize the adjustment of its treatment by insulin pump. Since a few years, several research programs aim for finalizing an automated system using the data of real time interstitial glucose to adjust automatically, via an algorithm, the release of insulin by the pump. This type of closed-loop system is for the moment only experimental, not still widely available in routine. On the other hand, rudimentary regulation systems partially automated already exist and can be used in common clinical practice. One of these systems, Smartguard ®, allows this type of regulation to decrease the hypoglycemic risk of the patients treated by insulin pump. It is indeed a hypo minimizer which interrupts the basal output when the algorithm embarked on the pump determines thanks to the CGM data what a hypoglycemia risks to occur in the 30 minutes. The efficiency of this system to reduce hypoglycemias was proved by several studies in pediatric and adult populations of subjects with DT1 (Diabetes Care on 2015; 38:1197-1204. J Diabetes Sci Technol. 2016 May 20. Pii: 1932296816645119). However, to date, there are no published data concerning the method of use of this system (sensor et pump initial configuration; patient education), nor the evolution of the sensor and pump parameters during the use.
The aim of this observationnelle study is to collect the data of efficiency, safety and use of the system Smartguard ® in common clinical practice in an adult population of subjects DT1.
Conditions
- Type 1 Diabetes Mellitus Maturity Onset
Sponsors & Collaborators
-
University Hospital, Caen
lead OTHER
Principal Investigators
-
Michael JOUBERT, MD · University Hospital, Caen
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-02-01
- Primary Completion
- 2018-01-01
- Completion
- 2018-01-01
Countries
- France
Study Locations
More Related Trials
-
Long Term CGM Treatment in Patients With Type 1 Diabetes Treated With Insulin Injections
NCT02465411 ·Status: COMPLETED ·Phase: NA
-
The Real-World Control-IQ Glycemic Control and Quality of Life Study in Type 1 Diabetes in France
NCT07211126 ·Status: RECRUITING
-
Effectiveness Study of the Guardian RT in Type 1 Diabetics
NCT01331343 ·Status: COMPLETED ·Phase: PHASE4
-
Obtain a Good Blood Glucose Control With the Paradigm Real Time System
NCT00441129 ·Status: COMPLETED ·Phase: NA
-
The MiniMed™ 780G Glycemic Control and Quality of Life Study for the Treatment of Pediatric and Adult Subjects With Type 1 Diabetes in France.
NCT04308291 ·Status: COMPLETED
-
Insulin Delivery Using the DBLG1 Closed-loop on Glycemic Control and PROMs in Adults Living With Type 1 Diabetes
NCT06154135 ·Status: ENROLLING_BY_INVITATION
-
Use of a Bearable Continuous Interstitial Glucose Monitoring Device (GuardianR) During Teaching Sessions to Functional Insulin Therapy Concept in Patients Suffering From Type 1 Diabetes: Evaluation at 6 and 12 Months
NCT00682903 ·Status: COMPLETED ·Phase: NA
-
Prevention of Hypoglycaemia With Predictive Insulin Suspend Using Sensor Augmented Insulin Pump in Children
NCT02179281 ·Status: COMPLETED ·Phase: NA
-
Initial Testing of the Diabeloop Algorithm in T1D Patients on Pump Therapy Over the Prandial Period and Physical Activity.
NCT01754181 ·Status: COMPLETED ·Phase: PHASE3
-
Glucose Counterregulation in Long Standing Type 1 Diabetes
NCT01474889 ·Status: COMPLETED ·Phase: NA
-
Effect of Automated Insulin Delivery on Early-stage Diabetic Complications
NCT05477030 ·Status: UNKNOWN ·Phase: NA
-
Real-life Data From Diabetic Patients on Closed-loop Pumps
NCT05418699 ·Status: COMPLETED
-
The Guardcontrol Trial: Study to Assess if Type 1 Diabetics Can Improve Using the Real-time Values of Guardian RT
NCT00111228 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study of Nocturnal Hypoglycemia Prevention in Type 1 Diabetes Using the Vigilant Diabetes Management Companion
NCT02906891 ·Status: TERMINATED ·Phase: NA
-
Real-life Follow-up of the Physical Activity in Type 1 Diabetes Participants Equipped With an Insulin Pump With Hybrid Closed Loop
NCT07015970 ·Status: COMPLETED
-
Comparison of SmartGuard vs Temp Target in Patients With Type 1 Diabetes Users of Advanced Hybrid Closed Loop System (AHCL) in Anaerobic Physical Activity.
NCT06728423 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Impact of the Mylife CamAPS FX System With the DEXCOM G6 Sensor on T1D Patients in France
NCT07048795 ·Status: RECRUITING
-
CGM Intervention in Teens and Young Adults With Type 1 Diabetes (T1D)
NCT03263494 ·Status: COMPLETED ·Phase: PHASE3
-
Safety and Efficacy of RT-CGMS in Patients With Type 1 Diabetes Mellitus Treated With an Implantable Pump
NCT00501072 ·Status: COMPLETED ·Phase: NA
-
Prediction and Prevention of Nocturnal Hypoglycemia in Persons With Type 1 Diabetes Using Machine Learning Techniques
NCT03711656 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 12 Days in Adults With Type 1 Diabetes
NCT02846831 ·Status: COMPLETED ·Phase: PHASE2
-
The Impact of Daily Carbohydrate Intake on Glycemic Control in Children and Adolescents With Type 1 Diabetes Using an Advanced Hybrid Closed-loop System
NCT05866900 ·Status: UNKNOWN
-
QUality of Control and slEep in Children With diabeteS, Using New Technology
NCT03103867 ·Status: COMPLETED ·Phase: NA
-
Continue Glucose Monitoring Before Insulin Pump
NCT02813421 ·Status: COMPLETED ·Phase: NA
-
Effect of CSII and CGM on Progression of Late Diabetic Complications
NCT01454700 ·Status: COMPLETED ·Phase: PHASE4