Miniscrews Placement for Orthodontic Anchorage
NCT06635304 · Status: ACTIVE_NOT_RECRUITING · Type: OBSERVATIONAL · Enrollment: 40
Last updated 2025-02-05
Summary
The goal of this retrospective observational mono-center study is to evaluate inter- and intra-operator variability and accuracy in miniscrews placement compared to CBCT-guided planning. The main questions it aims to answer are:
* Is there inter- and intra-operator variability in miniscrews placement?
* Is CBCT-guided placement more accurate than direct technique?
* Is there consistency among operators in identifying the third palatal ruga?
* Is there an influence of palatal vault morphology on these results?
The study will be conducted on a sample of 736 cases, that underwent digital planning for palatal mini-implants with the superimposition between the virtual model of the arch and the CBCT or latero-lateral teleradiography. The sample will be provided by a specialist in the field (Professor Giuseppe Perinetti, Adjunct Professor at Vita-Salute San Raffaele University) in anonymized form. From this sample the virtual models, that meet inclusion and exclusion criteria, will be selected and divided in two subgroups according to the palatal vault morphology (deep/flat) using the Korkhaus Index, which relates the distance between the first molars (specifically between the intersection point of the transverse groove and the buccal groove of each first molar) and the height of the palatal vault (i.e., the length of a vertical line perpendicular to the median palatal suture and the previously drawn line) setting the cutoff to determine the depth of the palatal vault at 42%. Below this percentage, the vault is considered flat; above this percentage, it is considered deep.
The operators involved will be orthodontists with varying levels of experience. At two different times, using Meshmixer software, they will digitally place a miniscrew in the left hemi-palate of each model and identify the most medial and lateral point of third palatal ruga. The placement of the miniscrews will be repeated by the same operators on the same models after a period of time.
Before proceeding with the placement, they will be instructed on the clinical references for positioning palatal mini-implants and on the use of Meshmixer software. Two trial placements will be proposed to make operators familiarize with the software and the described positioning parameters in the presence of an expert clinician.
The most adopted references in the literature, which will be therefore illustrated, are as follows:
* Placement at the third palatal ruga or up to 2 mm posteriorly, specifying that some authors discourage positioning directly over the third palatal ruga due to the risk of incorrect mini-implant angulation during insertion
* A distance from the midline ranging from 3 to 5 mm
* Regarding the inclination of the mini-implant, it was specified that Wilmes and co-authors recommend inserting it perpendicularly to the occlusal plane, although this parameter was not considered; what truly matters is the point where the mini-implant penetrates the bone.
The identification of the third ruga and the positioning of the mini-implant will occur at different times and in random order.
Data collected will be analyzed through statistical methods.
Conditions
- Miniscrew Placement
- Third Palatal Ruga
Sponsors & Collaborators
-
IRCCS San Raffaele
lead OTHER
Principal Investigators
-
Enrico Gherlone · IRCCS San Raffaele Hospital
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-01-07
- Primary Completion
- 2025-06-30
- Completion
- 2025-06-30
Countries
- Italy
Study Locations
More Related Trials
-
Comparison of the Efficiency of Maxillary Canine Retraction Using Aligners Versus Conventional Brackets in Orthodontic Extraction Cases.
NCT04333836 ·Status: UNKNOWN ·Phase: NA
-
Success Rate of the Miniscrews in the Mandibular Buccal Shelf
NCT05280678 ·Status: COMPLETED ·Phase: NA
-
Chesterfield Micro-implant Study Involving Three Types of Anchorage Methods in Orthodontics
NCT00995436 ·Status: COMPLETED ·Phase: NA
-
Accuracy, Stability and Safety of Orthodontic Mini-implant Template in the Infrazygomatic Crest Zone
NCT06786221 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison Between Effectiveness of Different Esthetic Orthodontic Appliances
NCT06803433 ·Status: COMPLETED ·Phase: NA
-
Does the Generation to Which the Operator Belongs Influence the Orthodontic Miniscrew Insertion Accuracy in Dynamic Computer-guided Surgery?
NCT06661551 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Dental Movements Using Clear Aligners Treatment: a Single-center Prospective Observational Study
NCT06561945 ·Status: NOT_YET_RECRUITING
-
Comparison of Two Orthodontic Clean-Up Protocols
NCT07304310 ·Status: COMPLETED
-
Comparative Evaluation of Gnathological Function With Bruxoff®
NCT06096753 ·Status: NOT_YET_RECRUITING
-
Accuracy of Maxillary Fixation Using Custom Plates on Nasal Buttress Only Via Minimally Invasive Approach Versus Custom Plates on Nasal and Zygomatic Buttresses Via Conventional Approach in Orthognathic Surgeries
NCT07311785 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Distal Movement of Maxillary Dentition With Zygomatic Miniplates Using Cone Beam Computed Tomography
NCT03467555 ·Status: COMPLETED ·Phase: NA
-
Transoral Versus Transbuccal Placement of Bicortical Screws During Orthognathic Surgery
NCT02658305 ·Status: COMPLETED
-
Clear Aligner Versus Removable Inclined Plane in Treatment of Anterior Crossbite
NCT06015386 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Mini Implant Supported Appliance and Headgear in Treatment of Maxillary Excess in Growing Patients
NCT03839303 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of The Accuracy of CAD-CAM Custom Made Titanium Miniplates In Positioning of the Genial Segment in Computer Guided Genioplasty
NCT03647865 ·Status: UNKNOWN ·Phase: NA
-
Morphological Changes of Removable Orthodontic Retainers During the Use
NCT06283823 ·Status: COMPLETED
-
OHRQoL and Accelerated Orthodontics With Micro-osteoperforations
NCT03407261 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Miniscrew Anchored Maxillary Protraction Protocols
NCT03712007 ·Status: COMPLETED ·Phase: NA
-
Effects of Mini Implant Facilitated Micro-osteoperforations on the Alignment of Mandibular Anterior Crowding
NCT04778241 ·Status: COMPLETED ·Phase: NA
-
Measuring Rate of Anteriors Retraction With Two Different Techniques
NCT05542745 ·Status: COMPLETED ·Phase: NA
-
Correction of Anterior Open Bite With Skeletally Anchored Extrusion Arch
NCT05492864 ·Status: COMPLETED ·Phase: NA
-
Removable Devices in Overjet Reduction
NCT06955637 ·Status: COMPLETED ·Phase: NA
-
"Augmented Reality-Assisted Miniscrew Placement in Orthodontics: A Clinical Trial"
NCT07112417 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Digital Three-Dimensional Root Position Prediction Via Digitized Models
NCT03552640 ·Status: UNKNOWN
-
Assessment of Mesiodistal Root Angulation Without Radiographic Guidance Versus CBCT Guidance: A Cross Sectional Study.
NCT06019351 ·Status: UNKNOWN