I-gel Plus Supraglottic Airway Device for Surgical Procedures in Prone Position
NCT06602817 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 28
Last updated 2025-06-08
Summary
I-gel Plus is a novel supraglottic airway device that has been evaluated in various studies with high success and low complication rates. Feasibility of supraglottic airway devices (SGA) in patients undergoing surgery in prone position has been demonstrated in some pilot studies and case series; however, the evidence is still limited. It is currently uncertain, if the i-gel Plus facilitates appropriate ventilation in individuals undergoing elective surgery in prone position.
The primary aim of this single-center non-inferior study is to assess the leak fraction of the i-gel Plus in patients undergoing surgery in prone position and to compare it with data from an existing prospective control cohort in patients undergoing surgery in supine position. Secondary aims are to investigate the oropharyngeal seal pressure and other secondary outcome parameters and to compare them with the control cohort.
Conditions
- General Anesthesia
- Airway Management
- Supraglottic Airway
Interventions
- OTHER
-
Exposure: prone position
Exposure: surgery in prone position
- OTHER
-
Exposure: Supine position
Exposure: Surgery in supine position
Sponsors & Collaborators
-
Universitätsklinikum Hamburg-Eppendorf
lead OTHER
Principal Investigators
-
Martin Petzoldt, MD · University Medical Center Hamburg-Eppendorf: Universitatsklinikum Hamburg-Eppendorf
Eligibility
- Min Age
- 18 Years
- Max Age
- 89 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-10-01
- Primary Completion
- 2025-02-04
- Completion
- 2025-02-04
Countries
- Germany
Study Locations
More Related Trials
-
Comparing the Efficiency of Three Third-generation Supraglottic Airways as an Intubation Route
NCT02975466 ·Status: COMPLETED ·Phase: NA
-
Requirements of Propofol With Target Controlled Infusions for Supraglottic Airway Devices
NCT04664595 ·Status: COMPLETED ·Phase: NA
-
Fiberoptic Evaluation of i-Gel and Air-Q sp3G Supraglottic Airway Devices in Pediatric Patients
NCT07141498 ·Status: COMPLETED
-
A Study Comparing the Supraglottic Airway Devices and Endotracheal Tube During Controlled Ventilation for Laparoscopic Surgery
NCT02462915 ·Status: UNKNOWN ·Phase: NA
-
Impact on Postoperative Pain of Three Single-use Adult Supraglottic Airway Devices in Short General Anesthetic Under Controlled Ventilation
NCT03614598 ·Status: COMPLETED ·Phase: NA
-
A Comparison of the I-gel and the Self-pressurised Air-Q Intubating Laryngeal Airway in Children
NCT02140008 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Infants
NCT01863316 ·Status: UNKNOWN ·Phase: NA
-
The Clinical Efficacy of Recently Developed Supraglottic Airway Device, I-gel™, in Neonates and Infants: Comparison With Classic-laryngeal Mask Airway (c-LMA)
NCT01437137 ·Status: COMPLETED ·Phase: NA
-
Does the Use of the GlideRite® Endotracheal Tube in Combination With the I-gel® Improve Intubation Success Rate?
NCT01265862 ·Status: COMPLETED ·Phase: NA
-
Comparison of I-gel to the Laryngeal Mask Airway
NCT00706823 ·Status: COMPLETED ·Phase: NA
-
The Insertion of I-gel and Classic LMA in Different Head Positions in Elderly Patients
NCT07027293 ·Status: RECRUITING ·Phase: NA
-
Ultrasound Imaging to Validate I-gel Placement in pediatrıc Patients
NCT04652466 ·Status: UNKNOWN
-
I-gel vs AuraGain for Bronchoscopic Intubation Through SGA
NCT04680169 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
NCT02026791 ·Status: COMPLETED ·Phase: NA
-
Insertion of Different Supraglottic Airway Devices on Manikin
NCT05523752 ·Status: COMPLETED ·Phase: NA
-
The Clinical Efficacy of Supraglottic Airway Device, Self-pressurized Air-Q Intubating Laryngeal Airway (ILA -SP) in Adult Patients: Comparison With Classic-laryngeal Airway (c-LMA)
NCT02206438 ·Status: COMPLETED ·Phase: NA
-
Mucosal Pressure of the Laryngeal Mask Airway Supreme Versus the i-Gel in Paralyzed Anesthetized Female Patients
NCT01367678 ·Status: COMPLETED ·Phase: NA
-
Comparison Between the I-gel and the LMA-Unique
NCT02163486 ·Status: COMPLETED ·Phase: NA
-
Comparison of Gastric Insufflation With the Classic Igel Laryngeal Mask and the New Igelplus Laryngeal Mask Using Gastric Ultrasound
NCT06578598 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
NCT02566135 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Type of Laryngeal Mask : I-Gel & LMA ProSeal
NCT00624403 ·Status: COMPLETED ·Phase: NA
-
A Comparison of the VBM Intubating Laryngeal Tube and the I-Gel
NCT03067246 ·Status: COMPLETED ·Phase: NA
-
Comparison Study of Two Supraglottic Airway Devices Used for Patients Under General Anesthesia
NCT01001078 ·Status: COMPLETED ·Phase: NA
-
Effect of Head-neck Rotation on I-gel™ Insertion
NCT05201339 ·Status: COMPLETED ·Phase: NA
-
I-gel vs. Endotracheal Intubation for Laparoscopic Gynaecological Procedures
NCT05782517 ·Status: COMPLETED ·Phase: NA