Longevity of Prefabricated Band and Loop Versus Conventional Band and Loop Space Maintainers
NCT06573463 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2024-08-28
Summary
To assess the longevity of prefabricated versus conventional band and loop space maintainers in children with prematurely lost first primary molars.
A Randomized Clinical Trial
Conditions
- Premature Tooth Exfoliation
Interventions
- DEVICE
-
Prefabricated band and loop
Prefabricated space maintainer requires only one visit as it fits into the patient's mouth at the clinic without needing the dental lab. It comes in a kit with different band sizes.
- DEVICE
-
Conventional Band and loop
Conventional band and loop is the most widely used space maintainer, It shows high success rate and good patient compliance, but needs more than one visit due to the laboratory work.
Sponsors & Collaborators
-
Cairo University
lead OTHER
Principal Investigators
-
Dina Y El Kharadly, Lecturer · October 6 University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 4 Years
- Max Age
- 6 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-12-01
- Primary Completion
- 2025-09-30
- Completion
- 2025-10-31
Countries
- Egypt
Study Locations
More Related Trials
-
Evaluation of The Stability of Orthodontic Treatment After First Premolar Extraction Using Combined Retention Protocol
NCT06502886 ·Status: RECRUITING ·Phase: NA
-
Bonded Bite Turbos Were Bonded to Palatal Surfaces of Maxillary Incisors for Sixty Patients With Anterior Deep Overbite to Check Acceptance Rate of Patients to These Bite Turbos.
NCT07143916 ·Status: COMPLETED ·Phase: NA
-
Comparative Assessment of Failure Rate of Fixed Lingual Retainer Between Two Types of Light Cured Resin Composite
NCT05660668 ·Status: UNKNOWN ·Phase: NA
-
Class II Malocclusion Correction Using the Mini-screw Supported Advanced Molar Distalization Appliance
NCT06726694 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Effectiveness of Different Esthetic Orthodontic Appliances
NCT06803433 ·Status: COMPLETED ·Phase: NA
-
Retentive Capacity of Bonded Retainer Vs Vacuum-formed and Combined Bonded-vacuum Retainers
NCT06476574 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique
NCT03572179 ·Status: COMPLETED ·Phase: NA
-
Comparison of Double Y-shaped Plates and Lag Screws in Fixation of Anterior Mandibular Fractures
NCT04396054 ·Status: COMPLETED ·Phase: NA
-
Effect of Modified Twin Block in Skeletal Class II Growing Females With Mandibular Deficiency
NCT03635463 ·Status: UNKNOWN ·Phase: NA
-
Evaluation Of Anchorage Control Using Arch Wire Stopper Versus Mini-Screws
NCT06416904 ·Status: COMPLETED ·Phase: NA
-
Dentoskeletal Effects of 3D-Printed Fixed Twin Block Versus MARA Appliances in Management of Skeletal Class II
NCT07340242 ·Status: RECRUITING ·Phase: NA
-
Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances: Direct Versus Indirect Anchorage
NCT06507319 ·Status: RECRUITING ·Phase: NA
-
Comparison of the Brackets Bonded With Bulk Fill Composite and Conventional Composite in Patients Undergoing Fixed Orthodontic Treatment
NCT07155343 ·Status: RECRUITING ·Phase: EARLY_PHASE1
-
Tooth Borne Versus Temporary Anchorage Devices (TAD) Based Intrusion Systems for the Correction of Anterior Deep Overbite
NCT06430710 ·Status: COMPLETED ·Phase: NA
-
Anterior Open Bite Closure by Clear Aligners Versus Fixed Appliances in Adult Patients With Skeletal Open Bite: A Randomized Clinical Trial.
NCT07117006 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of Dentoskeletal Changes After Treatment of Skeletal classII by Twinblock Versus Monoblock Appliances
NCT07277543 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Aesthetic Functional Appliances and Twin Block in Correction of Skeletal Class II
NCT06631235 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Effectiveness of Combined Design Nance/Transpalatal Arch Appliance in Maintaining Arch Dimensions After Premature Extraction of Primary Molars
NCT05514145 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Maxillary Posterior Teeth Intrusion by Skeletally Anchored Mousetrap Appliance in Adult Patient With Anterior Open Bite.
NCT06757686 ·Status: RECRUITING ·Phase: NA
-
Association Between Type of Ligating Brackets and Oral Health-related Quality of Life in Orthodontic Patients
NCT04773210 ·Status: UNKNOWN
-
Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment
NCT04718454 ·Status: UNKNOWN
-
A Comparison of Two Protocol for Maxillary Molar Intrusion Buccal Miniscrew and TPA Versus Vertical Holding Appliance
NCT05433051 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Augmented Reality-Assisted Bonding Versus Digitally-Assisted Indirect Bonding in Orthodontic Patients
NCT04658446 ·Status: UNKNOWN ·Phase: NA
-
Arrest of Proximal Caries Using Orthodontic Bands and Glass Ionomer Cement
NCT04538963 ·Status: UNKNOWN ·Phase: NA
-
Friction Versus Frictionless Mechanics During Maxillary En-masse Retraction in Adult Patients
NCT03261024 ·Status: UNKNOWN ·Phase: NA