LoW Dose-Intensity vs. Standard Dose-Intensity COntinuous Renal ReplaceMent Therapy in Critically Ill Patients (WISDOM)
NCT06446739 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2026-04-28
Summary
An estimated 10-15% of critically ill patients with acute kidney failure in the intensive care unit receive acute dialysis therapy. The majority of these patients initially receive a continuous form of dialysis therapy call continuous renal replacement therapy (CRRT). Prior studies have suggested that higher CRRT dose-intensity improved health outcomes for these patients; however, this was not found in high-quality clinical trials. These more recent trials suggested a lower range of dose-intensity compared with the higher range as the new standard of care. This was incorporated into guidelines. To date, no clinical trials have evaluated this lower range and specifically, it is plausible that an even lower dose-intensity of CRRT may be well tolerated, safe, associated with similar outcomes and be more cost-effective. This is the objective of the WISDOM trial, to compare the guideline standard with lower dose-intensity among patients who are started on CRRT in the intensive care unit.
Conditions
- Acute Kidney Injury
- Dialysis; Complications
Interventions
- DEVICE
-
Continuous Renal Replacement Therapy (CRRT)
Continuous Renal Replacement Therapy (CRRT) is a continuous form of acute renal replacement (hemofiltration/dialysis) therapy provided to critically ill patients with multi-organ dysfunction receiving life support in the intensive care unit (ICU).
Sponsors & Collaborators
-
University of Alberta
lead OTHER
Principal Investigators
-
Sean M Bagshaw, MD · University of Alberta
-
Ron Wald · St. Michael's Hospital (Unity Health)
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-11-14
- Primary Completion
- 2026-12-31
- Completion
- 2027-06-30
- FDA Device
- Yes
Countries
- United States
- Canada
- United Kingdom
Study Locations
More Related Trials
-
Exercise as an Adjunctive Therapy for Patients on Maintenance Hemodiafiltration
NCT06448598 ·Status: COMPLETED
-
Influence of Variable Inflow Volume, Dwell Duration and Glucose Concentration on Ultrafiltration Volume in APD Patients
NCT06443021 ·Status: WITHDRAWN ·Phase: NA
-
Efficacy of Convection-based HDF Compare With Diffusion-based HD in Sepsis-associated AKI
NCT06227104 ·Status: RECRUITING ·Phase: NA
-
Hannover Dialysis Outcome Study
NCT00529139 ·Status: COMPLETED ·Phase: PHASE4
-
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
NCT00004285 ·Status: COMPLETED ·Phase: NA
-
Machine Learning and Artificial Intelligence Algorithms to Optimize the Performance and Delivery of Acute Dialysis
NCT07312929 ·Status: NOT_YET_RECRUITING
-
An Innovative Virtually Supervised Exercise for Dialysis Patients
NCT03076528 ·Status: COMPLETED ·Phase: PHASE2
-
Comparison Study of Daily Ultrafiltration and Twice-weekly Hemodialysis
NCT00825318 ·Status: COMPLETED ·Phase: NA
-
Green Dialysis: Dialysis With Reduced Dialysate Flow
NCT05974436 ·Status: COMPLETED ·Phase: NA
-
Clinical Trial Comparing Continuous Versus Intermittent Hemodialysis in ICU Patients
NCT01228123 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Adjuvant Peritoneal Dialysis on a Background of Thrice-Weekly Hemodialysis
NCT02044614 ·Status: TERMINATED ·Phase: NA
-
Macrohemodynamic Impact of Fluid Removal With Net Ultrafiltration in Patients With Continuous Renal Replacement Therapy
NCT06425289 ·Status: NOT_YET_RECRUITING
-
Dialysis Exercise With a Bed Compatible Leg TRAiningstool
NCT06045442 ·Status: COMPLETED ·Phase: NA
-
Simulation for Continuous Veno-venous Hemofiltration in Intensive caRe
NCT02379234 ·Status: COMPLETED ·Phase: NA
-
Long-term, High Blood Flow Hemoadsorption Therapy in Patients Undergoing Maintenance Hemodialysis
NCT06574425 ·Status: ENROLLING_BY_INVITATION ·Phase: PHASE4
-
Intermittent ADVOS vs. Hemodialysis in Non-intensive Care Patients With Liver Dysfunction
NCT06129617 ·Status: RECRUITING ·Phase: NA
-
Effects of AN69 ST Hemofilter on Coagulation During Continuous Renal Replacement Therapy in Critically Ill
NCT01823484 ·Status: UNKNOWN ·Phase: NA
-
High Flux Hemodialysis Thrice Versus Once
NCT00714662 ·Status: UNKNOWN ·Phase: PHASE3
-
Effects of Variation of Sodium Dialysate in ICU
NCT03329313 ·Status: RECRUITING ·Phase: PHASE2
-
Dialysis Weaning in Intensive Care Units (Dialysis STOP)
NCT03763188 ·Status: COMPLETED
-
Resistance Exercise in Hemodialysis Patients
NCT06604221 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Optimisation of Anticoagulation in Patients on Nocturnal Hemodialysis
NCT05204810 ·Status: COMPLETED ·Phase: NA
-
Dietary Adherence Enhancement in Peritoneal Dialysis: BalanceWise-PD
NCT00447317 ·Status: COMPLETED ·Phase: NA
-
Continuous Hemodialysis With an Enhanced Middle Molecule Clearance Membrane
NCT01067313 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Comparison of Daily Nocturnal Hemodialysis With Daily Hemodialysis
NCT00012441 ·Status: UNKNOWN ·Phase: NA