Contrast Enhanced PA Pressure Measurements
NCT06240871 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 90
Last updated 2024-02-05
Summary
Pulmonary hypertension (PH) is an abnormal increase of the pressure inside the lung circulation. This condition can be caused by many different diseases. If PH persists for a long period of time, irreversible damage to the lung circulation and to the heart may ensue. A definitive diagnosis of PH requires direct measurement of the pressure within the lung circulation with a procedure called right heart catheterization (RHC). While overall safe, RHC is an invasive procedure and is associated with a small risk of complications (\~1.1%) and, very rarely, death (0.055%), even when performed in experienced laboratories. Therefore, alternative diagnostic approaches are often employed such as an ultrasound technique called Doppler echocardiography which is non-invasive, relatively inexpensive and widely available technique. It is suitable not only as a screening tool but also for serial monitoring of disease progression in PH. However, the accuracy of Doppler echocardiography in measuring pressure in the lung circulation appears to be modest in patients with suspected PH. To improve the performance of Doppler echocardiography it is common practice to inject a small amount of agitated saline or an echocardiographic contrast medium (usually composed of microbubbles of fat containing a minuscule amount of a gas) into a vein. However, the accuracy of using agitated saline or a contrast agent in the measurement of pressures inside the lung circulation has not been established. The proposed study will assess the accuracy of Doppler echocardiographic measurements of pressures in the pulmonary circulation by simultaneously comparing the pressures collected during a RHC. The investigators will enroll 100 consecutive patients undergoing RHC in the Catheterization Laboratory of Northwestern Memorial Hospital. The investigators will measure pulmonary pressures by RHC and by Doppler echocardiography at baseline and following the injection of agitated saline as well as Optison®, an FDA-approved contrast agent commonly used in the echo laboratory. The investigators will then determine the accuracy of the Doppler echocardiography measurement without and with the use of agitated saline or Optison® with the measurements obtained during the RHC which is the gold standard. The results of this study will allow determination whether the use of echo contrast improves the accuracy of Doppler echocardiography and whether contrast-enhanced Doppler measurements are a clinically useful alternative to RHC measurements.
Conditions
- Pulmonary Hypertension
Interventions
- OTHER
-
Pulmonary artery pressure measurements
The investigators will compare noninvasive measurements of right sided pressure measurements with invasive RHC performed in 3 steps:at rest, with agitated saline and with agitated echo contrast, Optison. This was not a clinical trial and there were no intervention arms per se. All patients received agitated saline and echocardiographic contrast.
Sponsors & Collaborators
-
GE Healthcare
collaborator INDUSTRY - lead OTHER
Principal Investigators
-
Kameswari Maganti · Northwestern University
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-09-30
- Primary Completion
- 2015-09-30
- Completion
- 2015-09-30
Countries
- United States
Study Locations
More Related Trials
-
U.S. CTEPH Registry
NCT02429284 ·Status: COMPLETED
-
Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03046264 ·Status: COMPLETED
-
Vital Signs Blood Pressure Trial
NCT06272318 ·Status: NOT_YET_RECRUITING
-
Activity Monitoring in Pulmonary Hypertension
NCT04101630 ·Status: ACTIVE_NOT_RECRUITING
-
Blood Pressure Assessment in Waiting Room During Pregnancy
NCT06248463 ·Status: NOT_YET_RECRUITING
-
Hypertension Management Using Remote Patient Monitoring
NCT05562921 ·Status: COMPLETED
-
Circulating MrgD in Pulmonary Hypertension
NCT06365372 ·Status: RECRUITING
-
Simultaneous Determination of Blood Pressure by Oscillometry and Photoplethysmography Compared to the Standard Inert Gas Rebreathing Technique
NCT02805413 ·Status: UNKNOWN ·Phase: NA
-
Accuracy Study of a Non-Invasive Blood Pressure Cuff in Comparison to an Invasive Radial Arterial Blood Pressure
NCT01485120 ·Status: COMPLETED ·Phase: NA
-
The Feasibility of a Web-based Application to Monitor Home Blood Pressure
NCT03116815 ·Status: COMPLETED ·Phase: NA
-
Hypertension in Long-Term Care Facilities
NCT03046420 ·Status: COMPLETED
-
Blood Pressure (BP) Visit Intensification Study
NCT02164331 ·Status: COMPLETED ·Phase: NA
-
Role of Wrist Based Blood Pressure Monitoring in Clinical Practice
NCT03862742 ·Status: WITHDRAWN
-
Measurement of NonInvasive Blood Pressure in Neonates Through Adults and Special Populations
NCT02125331 ·Status: TERMINATED
-
Study on Pressure Values Measured on Three Alternative Sites of the Lower Limbs Compared to the Arm
NCT02529735 ·Status: AVAILABLE
-
In-human Validation of a Technique for Measuring Central Aortic Hemodynamics With Peripheral Arterial Waveforms
NCT01567748 ·Status: COMPLETED
-
The Smart Hypertension Control Study
NCT03288142 ·Status: COMPLETED ·Phase: NA
-
Helping Hypertension Patients to Interpret Blood Pressure Readings and Motivate Blood Pressure Control
NCT04485637 ·Status: COMPLETED ·Phase: NA
-
Improving Health Outcomes: Blood Pressure
NCT02021981 ·Status: UNKNOWN
-
Comparing PPG-based Blood Pressure Measurement to the Gold Standard Manometer
NCT03810586 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Stendo Pulsating Suit on Microcirculation and Central Blood Pressure in Essential Hypertension Patients
NCT02277821 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Non-invasive Non-oscillometric Blood Pressure Wristband
NCT03629535 ·Status: COMPLETED ·Phase: NA
-
Comparisonbetween Primary Hypertension Monitoring Methods for Detection of Early Kidney Dysfunction
NCT03491813 ·Status: UNKNOWN
-
Somnotouch-NIBP Compared to Standard Ambulatory 24-hours Blood Pressure Measurement
NCT03975582 ·Status: COMPLETED
-
Somnotouch-NIBP Compared to Standard Ambulatory 24 Hours Blood Pressure Measurement
NCT03054688 ·Status: COMPLETED ·Phase: NA