Study on Pressure Values Measured on Three Alternative Sites of the Lower Limbs Compared to the Arm
NCT02529735 · Status: AVAILABLE · Type: EXPANDED_ACCESS
Last updated 2019-10-21
Summary
Non-invasive measurement of blood pressure is an instrument governed nursing routine care. The use of an automated oscillometric cuff is a common technique and validated if this is done on the arm with a suitable cuff, positioned opposite the brachial artery and up to the right atrium (the brachial site) . If cons-indication to use the brachial site, measurements are frequently performed at the ankle, calf or thigh. Among the blood pressure values measured on the 3 sites of the lower limb (thigh, calf or ankle), it may be a specific property of which the observed values are closest to the reference values (brachial).
The objective of this study is to measure the non-invasive blood pressure values at three sites of the lower limb, to compare the reference value to determine which alternative site should be preferred when the reference measurement is not feasible .
We want to determine the alternative site to obtain values as close as the measured values of the reference site. The three study sites are the thigh, calf and ankle. The reference site recommended for monitoring non-invasive blood pressureis the arm.
It is also assessing the impact of certain parameters on the primary endpoint:
* Physiological parameters: gender, weight, height, age, systolic blood pressure reference, listed measures.
* A parameter related to measurement: discomfort felt when the blood pressure outlet.
* Exposure setting: smoking.
Conditions
- Blood Pressure
Interventions
- OTHER
-
efficiency study
Blood pressure values measured for comparative lower limb and arm
Sponsors & Collaborators
-
Centre Hospitalier Sud Francilien
lead OTHER
Principal Investigators
-
Steven Lagadec, RN · Centre Hospitalier Sud Francilien
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
Countries
- France
Study Locations
More Related Trials
-
Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03046264 ·Status: COMPLETED
-
Non-invasive Blood Pressure (BP) Monitoring Compared to A-Line BP Monitoring
NCT00739700 ·Status: COMPLETED
-
Systolic Blood Pressure Measurement in Critically-ill Patients
NCT02366507 ·Status: COMPLETED
-
Comparisonbetween Primary Hypertension Monitoring Methods for Detection of Early Kidney Dysfunction
NCT03491813 ·Status: UNKNOWN
-
Accuracy of Non-invasive Blood Pressure Monitoring at the Wrist in Obese Patients
NCT03640429 ·Status: COMPLETED
-
Fresenius Noninvasive Blood Pressure Validation
NCT04573595 ·Status: COMPLETED ·Phase: NA
-
Nurse-led Program Efficacy on Blood Pressure Control
NCT04681703 ·Status: COMPLETED ·Phase: NA
-
Hypertension in Long-Term Care Facilities
NCT03046420 ·Status: COMPLETED
-
Arm and Finger Measurement for Blood Pressure Surveillance
NCT04012151 ·Status: ACTIVE_NOT_RECRUITING
-
International Registry for Ambulatory Blood Pressure and Arterial Stiffness Telemonitoring
NCT02577835 ·Status: COMPLETED
-
Accuracy Study of a Non-Invasive Blood Pressure Cuff in Comparison to an Invasive Radial Arterial Blood Pressure
NCT01485120 ·Status: COMPLETED ·Phase: NA
-
Body Structures Determining Differences in Forearm and Upper Arm Blood Pressures
NCT01087827 ·Status: COMPLETED
-
Non-Invasive Blood Pressure Measurement in Critically Ill PAtients Post Cardiosurgical Therapy
NCT03710473 ·Status: COMPLETED
-
Office Blood Pressure Measurement With an Automated Device
NCT03460249 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Novel Mobile Phone Application ( OptiBP) for Blood Pressure Monitoring
NCT04121624 ·Status: COMPLETED
-
Photoplethysmographic Measurements of Pulse Wave Velocity (PWV) and Blood Pressure (BP)
NCT05393401 ·Status: RECRUITING ·Phase: NA
-
Clinical Test for Armed-used Blood Pressure Monitor With Preformed Cuff
NCT01001455 ·Status: COMPLETED
-
Wrist Worn Blood Pressure Measurement
NCT03919136 ·Status: UNKNOWN
-
Clinical Usefullness of the Cuffless SOMNOtouch NIBP Device for 24-hour Ambulatory Blood Pressure Measurement
NCT04278001 ·Status: COMPLETED ·Phase: NA
-
Impact of Advanced Practical Nursing Intervention Versus Usual Care on Hypertension Control : Retrospective Study
NCT06227884 ·Status: COMPLETED
-
Validity Test of Wearable Continuous Blood Pressure Measuring System
NCT04261062 ·Status: UNKNOWN
-
Evaluation of Novel Optical Smartphone Application for Blood Pressure Measurements in Critically Ill Patients
NCT04728477 ·Status: COMPLETED
-
Smartphone Blood Pressure Measurement to Screen for Hypertension
NCT06577688 ·Status: RECRUITING
-
Blood Pressure Monitor Clinical Test (Cuff Range: 13.5cm-22cm)
NCT05978453 ·Status: COMPLETED
-
Blood Pressure Assessment in Waiting Room During Pregnancy
NCT06248463 ·Status: NOT_YET_RECRUITING