Simultaneous Determination of Blood Pressure by Oscillometry and Photoplethysmography Compared to the Standard Inert Gas Rebreathing Technique
NCT02805413 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 18
Last updated 2016-06-20
Summary
Main objective of the experiment is threefold: 1) to technically test a device for central blood pressure estimation for its applicability in a spaceflight-related environment and on the International Space Station. 2) Furthermore the objective is to compare central blood pressure estimates based on arterial pressure readings of different peripheral arteries. For central blood pressure estimation mathematical transfer functions as described by Karamanoglu and colleagues (11) will be used. 3) Finally the experiments' objective is to simultaneously apply phonocardiography together with ECG and carotid plethysmography to determine cardiac systolic time intervals in parabolic flight during gravity transitions.
Secondary objective of the experiment is to simultaneously measure key variables of the central circulation during gravity transitions to expand the understanding of cardiovascular regulation in weightlessness. Furthermore spirometric measurements shall be performed during a parabolic flight day to observe changes in end-expiratory CO2. Arterial CO2 content is central for cardiovascular regulation.
Our main hypothesis is that there is no difference between different methods of central arteria pressure determination.
Concerning our secondary objective, this experiment is designed as an observational study. Thus no clear hypothesis was generated but the measured cardiovascular and respiratory variables will be analysed regarding differences correlated to gravity.
Conditions
- BLOOD PRESSURE
Interventions
- OTHER
-
Détermination and comparison of blood pressure
Rebreathings will be performed every parabola (2, 4, 6, 8, 10…). Ultrasound measurements will be performed during the remaining parabolas (1, 3, 5, 7, 9…). The procedure consists of a fixed breathing frequency of 20 breaths per minute and an exact triggered start point for the measurements. . Central blood pressure measurements, finger blood pressure measurements, impedance cardiography, carotid plethysmography and phonocardiography will be performed continuously during the flights. The breaks between parabolas 10 and 11 and 20 and 21 will be used to change subjects, which takes approximately 5 minutes.
Sponsors & Collaborators
-
Novespace
collaborator INDUSTRY -
University Hospital, Caen
lead OTHER
Principal Investigators
-
Pierre DP Denise, PhD · CHU CAEN
Study Design
- Allocation
- NA
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2015-04-30
- Primary Completion
- 2018-04-30
- Completion
- 2018-04-30
Countries
- France
Study Locations
More Related Trials
-
Agreement and Precision of a Smartphone Application For Continuous Blood Pressure Monitoring
NCT04119193 ·Status: COMPLETED
-
Clinical Feasibility of a Conformal Ultrasound Blood Pressure Sensor
NCT05909605 ·Status: COMPLETED
-
Comparisonbetween Primary Hypertension Monitoring Methods for Detection of Early Kidney Dysfunction
NCT03491813 ·Status: UNKNOWN
-
International Registry for Ambulatory Blood Pressure and Arterial Stiffness Telemonitoring
NCT02577835 ·Status: COMPLETED
-
Optical System to Continuously Measure Arterial Blood Pressure
NCT02651558 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Novel Optical Smartphone Application for Blood Pressure Measurements in Critically Ill Patients
NCT04728477 ·Status: COMPLETED
-
Telemonitoring of Uncontrolled Hypertension
NCT02730052 ·Status: WITHDRAWN ·Phase: NA
-
Systolic Blood Pressure Measurement in Critically-ill Patients
NCT02366507 ·Status: COMPLETED
-
Hypotension Prediction Index: Correlations Between Invasive and Non-invasive Pressure Points.
NCT05025176 ·Status: ACTIVE_NOT_RECRUITING
-
Efficacy of Home Blood Pressure Monitoring (MONITOR Study)
NCT00921791 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Novel Mobile Phone Application ( OptiBP) for Blood Pressure Monitoring
NCT04121624 ·Status: COMPLETED
-
Non-invasive Blood Pressure (BP) Monitoring Compared to A-Line BP Monitoring
NCT00739700 ·Status: COMPLETED
-
Photoplethysmographic Measurements of Pulse Wave Velocity (PWV) and Blood Pressure (BP)
NCT05393401 ·Status: RECRUITING ·Phase: NA
-
Evaluation of a New Blood Pressure Measuring Device.
NCT00265707 ·Status: UNKNOWN ·Phase: NA
-
Alterations in Autonomic Cardiovascular Control Induced at Partial G Forces
NCT02517177 ·Status: COMPLETED ·Phase: NA
-
Measurement of NonInvasive Blood Pressure in Neonates Through Adults and Special Populations
NCT02125331 ·Status: TERMINATED
-
Automatic and Conventional Methods of Hypertensive Patients Monitoring
NCT06929728 ·Status: NOT_YET_RECRUITING
-
Ambulatory Blood Pressure Monitoring in Children
NCT01070342 ·Status: COMPLETED
-
Contactless Radar Blood Pressure Validation
NCT06035107 ·Status: NOT_YET_RECRUITING
-
Remote Blood Pressure Management Clinical Application Research
NCT04690478 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Non-invasive Blood Pressure Monitoring at the Wrist in Obese Patients
NCT03640429 ·Status: COMPLETED
-
Registry Study on "Control Nocturnal Hypertension to Reach the Target "
NCT04137549 ·Status: RECRUITING
-
Technology for Innovative Monitoring of Cardiovascular Prevention: a RCT
NCT03005470 ·Status: UNKNOWN ·Phase: PHASE3
-
24-hour Ambulatory Blood Pressure Monitoring in Patients With Blood Pressure Above Thresholds in General Practice
NCT03774147 ·Status: UNKNOWN
-
Non-invasive Blood Pressure Measurement Using Samsung Smartwatch
NCT05302193 ·Status: COMPLETED ·Phase: NA