Influence of CleaRing Open-capsule Device on Refractive Predictability in Cataract Patients (Part 2)
NCT06083025 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 25
Last updated 2023-10-13
Summary
The Hanita CleaRing device is an intraocular implant designed for inhibition of PCO leading to reduction in the Nd:YAG treatment rate. The device is implanted into the capsular bag after the extraction of the crystalline lens and prior to implantation of the IOL. The device is manufactured by Hanita Lenses from a hydrophilic acrylic co-polymer which is being used for the production of Intra-ocular lenses.
Conditions
- Posterior Capsule Opacification
Interventions
- DEVICE
-
CleaRing
The Hanita CleaRing device is an intraocular implant designed for inhibition of PCO leading to reduction in the Nd:YAG treatment rate. The device is implanted into the capsular bag after the extraction of the crystalline lens and prior to implantation of the IOL. The device is manufactured by Hanita Lenses from a hydrophilic acrylic co-polymer which is being used for the production of Intra-ocular lenses.
Sponsors & Collaborators
-
Hanita Lenses
lead INDUSTRY
Principal Investigators
-
Guy Kleinmann, Prof. · Wolfson MC
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 50 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-04-15
- Primary Completion
- 2025-03-01
- Completion
- 2025-04-01
Countries
- Israel
Study Locations
More Related Trials
-
Precisight® Intraocular Lens Implantation for Cataract Treatment
NCT02970487 ·Status: UNKNOWN ·Phase: NA
-
Aqueous Flare of a Hydrophobic Acrylic Single-piece Open-loop IOL With Modified Material Surface Properties
NCT01767012 ·Status: COMPLETED ·Phase: PHASE4
-
Capsule Bag Performance of a Novel Single-piece Acrylic IOL HOYA AF-1 NY-60
NCT07167589 ·Status: COMPLETED ·Phase: NA
-
Influence of Two Different Preloaded Intraocular Lens (IOLs) on Posterior Capsule Opacification
NCT00673803 ·Status: COMPLETED ·Phase: PHASE4
-
Performance of Two Sclera Fixated Intraocular Lens Concepts
NCT05779306 ·Status: COMPLETED
-
Reading Performance in Patients With Acrysof IQ Vivity Versus Acrysof IQ
NCT05194657 ·Status: UNKNOWN ·Phase: NA
-
Evaluate the Safety and Effectiveness of the AccuraSee™ IOPCL for Secondary Implantation in the Capsular Bag to Improve Near and/or Intermediate Vision Following Previous Cataract Surgery
NCT06625749 ·Status: RECRUITING ·Phase: NA
-
Posterior Capsule Opacification Development With Two Different Intraocular Lenses
NCT01734343 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study to Evaluate the KeraKlear Keratoprosthesis in Patients With Corneal Opacity
NCT03126903 ·Status: TERMINATED ·Phase: NA
-
Clinical Evaluation Study for Assessing the Visual Performance of Hanita Lenses Trifocal IOL
NCT04843748 ·Status: COMPLETED ·Phase: NA
-
Long-term Result of Placing Intracorneal Rings in Keratoconus Using Laser
NCT05596838 ·Status: ACTIVE_NOT_RECRUITING
-
Assessing The Visual Performance Of Hanita Lenses "Intensity SL" Intraocular Lens
NCT05504343 ·Status: COMPLETED ·Phase: NA
-
Cross-Linking ACcéléré Iontophorèse Confocal kératocONE
NCT03429569 ·Status: UNKNOWN ·Phase: PHASE4
-
Posterior Capsule Opacification and Frequency of Nd:YAG Treatment and of Two Microincision IOLs: Hoya iMics NY-60 vs Acrysof SN60WF
NCT01732484 ·Status: COMPLETED ·Phase: NA
-
Clinical Investigation of Healon EndoCoat Ophthalmic Viscosurgical Device (OVD)
NCT05575063 ·Status: COMPLETED ·Phase: NA
-
Clareon PanOptix Versus AcrySof PanOptix : Prospective Study Comparing Contrast Sensitivity
NCT07158177 ·Status: RECRUITING ·Phase: NA
-
Assessment of Visual Performance Combining a Symfony IOL and a +3.25 Tecnis Multifocal IOL
NCT02847572 ·Status: COMPLETED ·Phase: NA
-
Surgical Outcomes After Routine Cataract Extraction & Implantation of a Conventional or Spheric Intraocular Lens
NCT00366496 ·Status: COMPLETED ·Phase: NA
-
Collagen Cross-linking in Keratoconus
NCT03760432 ·Status: RECRUITING ·Phase: NA
-
Posterior Capsule Opafication of Different Hydrophobic Acrylic Intraocular Lenses: Vivinex iSert P261 vs.Clareon IOL
NCT04369482 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Safety and Performance Outcomes of Eyedeal IOL Implantation After Cataract Removal
NCT05776095 ·Status: RECRUITING ·Phase: NA
-
Rotation of an Intraocular Lens - HOYA Vivinex iSert P261
NCT03157375 ·Status: COMPLETED ·Phase: NA
-
A Prospective, Randomized, Subject and Vision-assessor Masked, Multicenter Study Comparing Bilateral Clareon PanOptix, Bilateral Clareon PanOptix Pro, and Mixed Clareon PanOptix Pro/Vivity Intraocular Lens Implantation in Cataract Subjects
NCT06922084 ·Status: RECRUITING ·Phase: PHASE4
-
Visual Performance of Clareon Vivity and PureSee IOL
NCT07165197 ·Status: RECRUITING ·Phase: NA
-
Non-inferiority Trial of Iontophoretic Corneal Collagen Crosslinking (CXL) Compared to Standard Corneal Collagen Crosslinking in Progressive Keratoconus.
NCT01868620 ·Status: TERMINATED ·Phase: NA