Pilot Feasibility Trial of the SafeLM Supraglottic Airway (SGA)
NCT05989880 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2024-12-10
Summary
The purpose of this study is to assess the feasibility of SafeLM as a primary airway device and as a conduit for intubation with and without the use of a bougie
Conditions
- Anesthesia
Interventions
- DEVICE
-
SafeLM as a supraglottic airway device with video capability
The device will be inserted using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
- DEVICE
-
SafeLM as a supraglottic airway device without video capability
The device will be blindly inserted without using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The video capability of the device will be used to assess the accuracy of placement after the fact. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
- DEVICE
-
SafeLM as a conduit for intubation using an endotracheal tube with video capability
The device will be inserted, and an endotracheal tube will be advanced through the device under direct visualization using the video capability of the device. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The endotracheal tube will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device. The endotracheal tube will be advanced into the trachea, and the position will be confirmed by end-tidal carbon dioxide (EtCO2) detection and chest auscultation. The cuff of the endotracheal tube will be inflated, and mechanical ventilation will be resumed. The SafeLM device will be removed, and the position of the endotracheal tube will be confirmed once again.
- DEVICE
-
SafeLM as a conduit for intubation using a bougie with video capability
The device will be inserted. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.The position of the device will be confirmed by observing the video image of the glottis on the monitor. The video camera on the SafeLM will be turned on to visualize the vocal cords.A standard airway bougie will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.The SafeLM device will be removed, and an appropriately sized endotracheal tube will be advanced into the trachea. If a bougie is not able to be inserted into the tracheal under direct visualization, direct insertion of an endotracheal tube into the trachea will be attempted, followed by flexible scope intubation.
Sponsors & Collaborators
-
The University of Texas Health Science Center, Houston
lead OTHER
Principal Investigators
-
Lauren M Nakazawa, MD · The University of Texas Health Science Center, Houston
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-09-19
- Primary Completion
- 2025-10-02
- Completion
- 2025-12-02
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
The Safety and Efficacy of Supraglottic Airway Use in Children
NCT02202174 ·Status: UNKNOWN
-
Does the Use of the GlideRite® Endotracheal Tube in Combination With the I-gel® Improve Intubation Success Rate?
NCT01265862 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Fiberoptic Endotracheal Intubation Between the Intubating Laryngeal Tube Suction and the LMA Protector
NCT04618926 ·Status: UNKNOWN
-
Supreme LMA and Endotracheal Intubation Use in Caesarean Section
NCT01858467 ·Status: COMPLETED ·Phase: NA
-
Comparison Study of Two Supraglottic Airway Devices Used for Patients Under General Anesthesia
NCT01001078 ·Status: COMPLETED ·Phase: NA
-
Utilization of Airway Stabilizing Rod
NCT05899868 ·Status: COMPLETED ·Phase: NA
-
Assessment of the I-gel and Air-Q Supraglottic Airways as Conduits for Tracheal Intubation in Children
NCT02189590 ·Status: COMPLETED ·Phase: NA
-
Blind Tracheal Intubation Through Supraglottic Airway Devices
NCT05624073 ·Status: UNKNOWN
-
Performance of the I-gel and the Laryngeal Tube Suction Disposable by Novice Intubators"
NCT04909944 ·Status: UNKNOWN ·Phase: NA
-
Safety and Efficacy of the LMA Supreme When Inserted With Patients in the Prone Position
NCT03633942 ·Status: UNKNOWN
-
Study Comparing Intubation Via Video Laryngeal Mask Airways (VLMAs) Versus Video Laryngoscopy
NCT06396234 ·Status: WITHDRAWN ·Phase: NA
-
Application of I-gel Laryngeal Mask Airway in Pediatric Patients
NCT03748589 ·Status: COMPLETED ·Phase: NA
-
Comparison of I-gel to the Laryngeal Mask Airway
NCT00706823 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Use of Tracheal Intubation Through a Laryngeal Tube to Intubate Anesthetized Patients
NCT03165461 ·Status: COMPLETED
-
Comparison of LMA-Fastrach and I-gel for Blind Tracheal Intubation.
NCT01007370 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Laryngeal Mask Airways in Sinonasal Surgery
NCT02311153 ·Status: COMPLETED ·Phase: NA
-
Comparison of Intubation Using Video Laryngeal Mask and Video Laryngoscope in Elective Surgical Patients
NCT07057908 ·Status: NOT_YET_RECRUITING
-
I-gel vs AuraGain for Bronchoscopic Intubation Through SGA
NCT04680169 ·Status: COMPLETED ·Phase: NA
-
Ambu AuraGain and Teleflex LMA Protector Fiberoptic Assessments in Elective Patients
NCT02724956 ·Status: COMPLETED ·Phase: NA
-
The Effect of a New Supraglottic Airway With Built-in Cuff Pressure Indicator
NCT01800344 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
NCT02026791 ·Status: COMPLETED ·Phase: NA
-
Structural Modification In Supraglottic Airway Device
NCT04498598 ·Status: RECRUITING ·Phase: NA
-
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
NCT02566135 ·Status: COMPLETED ·Phase: NA
-
A New Insertion Technique for Laryngeal Mask Airway
NCT01749033 ·Status: COMPLETED ·Phase: NA
-
Ambu® Laryngeal Mask as an Intubation Conduit
NCT00272194 ·Status: COMPLETED ·Phase: PHASE4