Improving Grasp Function in People With Sensorimotor Impairments by Combining Electrical Stimulation With a Robotic Hand Orthosis
NCT05976087 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2025-08-19
Summary
Hand motor and sensory impairments resulting from neurological disorders or injuries affect more than 50 million individuals worldwide. Conditions such as stroke, spinal cord injury (SCI), and traumatic brain injury (TBI) can cause long-term hand impairments, greatly impacting daily activities and social integration. Since traditional physiotherapy has limited effectiveness in rehabilitation, assistive devices helping in performing in daily activities have emerged as a necessary solution. Soft exoskeletons offer advantages as they are more comfortable and adaptable for the user, but they often struggle to generate sufficient force. On the other hand, electrical stimulation garments, like e-sleeves, show promise by stimulating nerves and muscles in the forearm. However, achieving precise and stable movement control remains challenging due to difficulties in electrode placement for targeted stimulation. Furthermore, none of the currently available devices are capable of artificially restoring lost sensation in users' hands, limiting their ability to manipulate with fragile objects.
Recognizing these limitations, our study proposes a solution that combines a standard hand soft exoskeleton with: (i) electrical stimulation to the fingers' flexor and extensor muscles to generate artificial muscle contractions synchronized with the exoskeleton motion, compensating for the lack of gripping force, and (ii) electrical stimulation to the nerves to artificially restore the lost sensation of touch, enabling users to receive feedback on the force they are applying when interacting with the environment. The investigators refer to this proposed combination as Sensible-Exo.
To achieve this goal, our project aims to evaluate the functional improvements in assistive and rehabilitative scenarios using SensoExo in comparison to use only the exoskeleton or having no support at all. The exoskeleton will be coupled with an electrical stimulating sleeve capable of delivering non-invasive electrical stimulation in the form of Functional Electrical Stimulation (FES) and Transcutaneous Electrical Nerve Stimulation (TENS). A glove with embedded force and bending sensors will be used to modulate the electrical stimulation. Additionally, apart from studying the enhancement of functional tasks, the investigators will explore improvements in body perception, representation, and multi-sensory integration. Indeed, the investigators also aim at identifying the way patients perceive their body by means of ad-hoc virtual reality assessments that has been developed. Before each assessment patient will perform some predefined movement in virtual reality to familiarize with it and increase embodiment.
During the study, participants will perform a range of tasks based on their residual abilities, including motor tasks (e.g., grab and release, Toronto Rehabilitation Institute Hand Function Test, grip force regulation test, virtual egg test), cognitive tasks (dual tasks), and assessments of body representation and perception. Some of these tasks will be conducted in Virtual Reality environments, both with and without active stimulation.
Conditions
- Stroke
- Spinal Cord Injuries
- Traumatic Brain Injury
Interventions
- DEVICE
-
SensoExo
combination of sensory feedback and the use of soft exoskeleton
Sponsors & Collaborators
-
Andrea Cimolato
lead OTHER
Principal Investigators
-
Stanisa Raspopovic, PhD · ETH Zurich
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-07-01
- Primary Completion
- 2026-06-30
- Completion
- 2030-06-30
Countries
- Switzerland
Study Locations
More Related Trials
-
Electrical Stimulation to Improve Hand Function in Patients With Chronic Stroke
NCT00023569 ·Status: COMPLETED
-
Effectiveness of Robot-assisted Rehabilitation in Persons With Stroke
NCT04002076 ·Status: UNKNOWN ·Phase: NA
-
Hand Rehabilitation Study for Stroke Patients
NCT03148106 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Arm Use With Soft-robotic Glove
NCT06033027 ·Status: RECRUITING ·Phase: NA
-
Assessment of a Physio-neuro Platform (SynPhNe) for Home-based Retraining of Hand Function in Stroke Survivors
NCT02896348 ·Status: RECRUITING ·Phase: NA
-
Precision Sensorimotor Neurorehabilitation Through Personalized Stimulation Loops
NCT06466772 ·Status: RECRUITING ·Phase: NA
-
Robotically Augmented Mental Practice
NCT04962698 ·Status: COMPLETED ·Phase: NA
-
Portable EMG-triggered Hand Robot for Individuals After Stroke
NCT02364700 ·Status: COMPLETED ·Phase: NA
-
New Interactive Sensor-home-based Hand Training to Improve Dexterity
NCT06062693 ·Status: RECRUITING ·Phase: NA
-
Hand and Arm Motor Recovery Via Non-invasive Electrical Spinal Cord Stimulation After Stroke
NCT05591196 ·Status: RECRUITING ·Phase: NA
-
Restoring High Dimensional Hand Function to Persons With Chronic High Tetraplegia
NCT03482310 ·Status: COMPLETED ·Phase: NA
-
Robotic Brace Incorporating Electromyography (EMG) for Moderate Affected Arm Impairment After Stroke
NCT01322997 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Combined Brain and Peripheral Nerve Stimulation for Stroke
NCT01907737 ·Status: COMPLETED ·Phase: NA
-
Influence of Sensory Electrical Stimulation on Hand Functions in Chronic Stroke Patients
NCT06826976 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Proprioceptive Sensorimotor Integration With Neural Interfaces for Hand Prostheses
NCT04947462 ·Status: RECRUITING ·Phase: NA
-
Effects of EMG-driven Robot-assisted Therapy for the Distal Upper Limb Motor Function in the Chronic Stroke Patients With Botox Injections
NCT04502264 ·Status: COMPLETED ·Phase: PHASE2
-
Effect of SynPhNe Physio-neuro Platform on Hand Motor Function Rehabilitation of Acute and Subacute Stroke Patients
NCT05133232 ·Status: COMPLETED ·Phase: NA
-
Neuroplasticity With Daily Use of a Sensorimotor Priming Vibration System to Improve Hand Function After Stroke
NCT04026399 ·Status: COMPLETED ·Phase: NA
-
Function Benefits of a Myoelectric Elbow-Wrist-Hand Orthosis
NCT02544672 ·Status: UNKNOWN ·Phase: NA
-
Using Tablets for Upper Extremity Rehabilitation Post Acquired Brain Injury
NCT02136433 ·Status: UNKNOWN ·Phase: NA
-
Motor Imagery for Reach-to-grasp Rehabilitation After Tetraplegia
NCT02860403 ·Status: COMPLETED ·Phase: NA
-
Neurocognitive Robot-assisted Rehabilitation of Hand Function After Stroke
NCT02096445 ·Status: COMPLETED ·Phase: NA
-
NMDA Receptors in Motor Learning in Humans
NCT02082912 ·Status: COMPLETED ·Phase: PHASE2
-
Robotic Therapy and Brain Stimulation in the Early Phase After Stroke
NCT03230695 ·Status: UNKNOWN ·Phase: NA
-
Using EMG of the Healthy Hand to Control TENS of the Affected Hand in Hemiparetic Patients
NCT03146559 ·Status: UNKNOWN ·Phase: NA