Validation of the Apnea Test Performed by High-flow Oxygen Therapy in Patients With Clinical Brain Death

NCT05950178 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15

Last updated 2024-08-02

No results posted yet for this study

Summary

Brain death is a clinical and paraclinical diagnosis established in a known etiological context. It involves the irreversible destruction of cerebral functions in a beating-heart individual.

In the context of organ and tissue donation from a critically ill patient, the clinical diagnosis of brain death is confirmed through a mandatory apnea test. This test is conducted by disconnecting the patient from the ventilator for a duration of 8 to 10 minutes. The test is considered validated when there is no spontaneous respiratory movement and the presence of hypercapnia. Hypercapnia is defined as a PaCO2 (carbon dioxide partial pressure) greater than 60 mmHg or an increase of more than 20 mmHg compared to the pre-ventilator disconnection capnia. These thresholds are meant to provide a strong stimulus to the respiratory centers, objectively confirming the absence of spontaneous ventilation.

In practice, the apnea test is performed under CPAP (Continuous Positive Airway Pressure) or by administering oxygen at 6-10L/min through the endotracheal tube.

High-flow oxygenation could be a simple alternative for the apnea test during the validation of the clinical diagnosis of brain death while reducing the risk of lung derecruitment and compromising organ viability and/or lung donation.

However, due to the high gas flow used (60 L/min), high-flow oxygenation can lead to a "washout" effect in the anatomical dead space, which may lower the carbon dioxide partial pressure. Consequently, even in a patient in a state of brain death, where spontaneous ventilation is absent by definition, it is not certain that the carbon dioxide partial pressure will increase to the threshold of 60 mmHg or more than 20 mmHg in 10 minutes during an apnea test conducted with high-flow oxygenation.

The purpose of this study is, therefore, to examine the feasibility of clinically diagnosing brain death through an apnea test performed with high-flow oxygenation.

To determine whether the validation criterion which involves observing an arterial capnia \> 60 mmHg or an increase \> 20 mmHg (compared to the capnia at the beginning of the test) after 10 minutes can be achieved during an apnea test conducted under high-flow oxygen therapy in patients with clinically confirmed brain death by standard apnea test (under standard oxygen therapy)

Conditions

  • Brain Death

Interventions

DIAGNOSTIC_TEST

Apnea test under high-flow oxygenation

Apnea test under high-flow oxygenation in patients with a confirmed clinical brain death by a standard apnea test (under standard oxygen therapy)

Sponsors & Collaborators

  • Centre Hospitalier Régional d'Orléans

    lead OTHER

Principal Investigators

  • Damien BARRIER · CHR d'Orléans

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No