10°C vs 4°C Lung Preservation RCT
NCT05898776 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 317
Last updated 2026-03-19
Summary
Despite lung transplantation (LTx) being the most effective treatment for end-stage lung disease, its success rate is lower than that of other solid organ transplantations. Primary graft dysfunction (PGD) is the most common post-operative complication and a major factor in early mortality and morbidity, affecting \~25% of lung transplant patients. Induced by ischemia reperfusion, PGD represents a severe and acute lung injury that occurs within the first 72 hours after transplantation, and has a significant impact on short- and long-term outcomes, and a significant increase in treatment costs. Any intervention that reduces the risk of PGD will lead to major improvements in short- and long-term transplant outcomes and health care systems.
One of the main strategies to reduce the risk and severity of post-transplant PGD is to improve pre-transplant donor lung preservation methods. In current practice, lung preservation is typically performed by cold flushing the organ with a specialized preservation solution, followed by subsequent hypothermic storage on ice (\~4°C). This method continues to be used and applied across different organ systems due to its simplicity and low cost. Using this method for the preservation of donor lungs, the current maximum accepted preservation times have been limited to approximately 6-8h. While the goal of hypothermic storage is to sustain cellular viability during ischemic time through reduced cellular metabolism, lower organ temperature has also been shown to progressively favor mitochondrial dysfunction. Therefore, the ideal temperature for donor organ preservation remains to be defined and should maintain a balance between avoidance of mitochondrial dysfunction and prevention of cellular exhaustion. In addition to that, safe and longer preservation times can lead to multiple advantages such as moving overnight transplants to daytime, more flexibility to transplant logistics, more time for proper donor to recipient matching etc.
Building on pre-clinical research suggesting that 10°C may be the optimal lung storage temperature, a prospective, multi-center, non-randomized clinical trial was conducted at University Health Network, Medical University of Vienna and Puerta de Hierro Majadahonda University Hospital. Donor lungs meeting criteria for direct transplantation and with cross clamp times between 6:00pm - 4:00am were intentionally delayed to an earliest allowed start time of 6:00am and a maximum preservation time from donor cold flush to recipient anesthesia start time of 12 hours. Lungs were retrieved and transported in the usual fashion using a cooler with ice and transferred to a 10°C temperature-controlled cooler upon arrival to transplant hospital until implantation. The primary outcome of this study was incidence of Primary Graft Dysfunction (PGD) Grade 3 at 72h, with secondary endpoints including: recipient time on the ventilator, ICU Length of Stay (LOS), hospital LOS, 30-day survival and lung function at 1-year. Outcomes were compared to a contemporaneous conventionally transplanted recipient cohort using propensity score matching at a 1:2 ratio. 70 patients were included in the study arm. Post-transplant outcomes were comparable between the two groups for up to 1 year. Thus, intentional prolongation of donor lung preservation at 10°C was shown to be clinically safe and feasible.
In the current study design, the investigators will conduct a multi-centre, non-inferiority, randomized, controlled trial of 300 participants to compare donor lung preservation from the time of explant to implant at \~10°C in X°Port Lung Transport Device (Traferox Technologies Inc.) vs a standard ice cooler. When eligible donor lungs become available for a consented recipient, the lungs will be randomized to undergo a preservation protocol using either 10°C (X°Port Lung Transport Device, Traferox Technologies Inc.) or standard of care. The primary outcome of the study is incidence of ISHLT Primary Graft Dysfunction Grade 3 at 72 hours. Post-transplant outcomes will be followed for one year.
Conditions
- Lung Transplant
- Organ Preservation
Interventions
- DEVICE
-
Lung transplantation after 10°C donor lung preservation
When suitable donor lungs become available for a, eligible, consented recipient and meet criteria to go straight to transplantation, the lungs randomized to 10°C preservation will be stored, transported and preserved in the X°Port Lung Transport Device (Traferox Technologies Inc.) until implant with a maximum time of 12 hours between the donor and recipient surgeries.
- DEVICE
-
Lung transplantation after standard ice cooler donor lung preservation
When suitable donor lungs become available for a, eligible, consented recipient and meet criteria to go straight to transplantation, the lungs randomized to standard preservation will be will be stored, transported and preserved in an ice cooler (\~4°C, standard of care) until implant with a maximum time of 6 hours between the donor and recipient surgeries.
Sponsors & Collaborators
-
Medical University of Vienna
collaborator OTHER -
Vanderbilt University
collaborator OTHER -
Puerta de Hierro University Hospital
collaborator OTHER -
University of California, San Francisco
collaborator OTHER -
Centre Hospitalier Universitaire Vaudois
collaborator OTHER - collaborator OTHER
-
St Vincent's Hospital, Sydney
collaborator OTHER -
University of Texas Southwestern Medical Center
collaborator OTHER -
Corewell Health West
collaborator OTHER -
University of Miami
collaborator OTHER -
University Hospital of Leuven Leuven
collaborator OTHER -
Centre hospitalier de l'Université de Montréal (CHUM)
collaborator OTHER -
University Hospital, Zürich
collaborator OTHER -
Dignity Health
collaborator OTHER -
Hospital Universitario 12 de Octubre
collaborator OTHER -
Marie Lannelongue Hospital, Le Plessis Robinson, France
collaborator UNKNOWN -
University Health Network, Toronto
lead OTHER
Principal Investigators
-
Elliot Wakeam, MD MPH · University Health Network, Toronto
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-06-09
- Primary Completion
- 2025-11-24
- Completion
- 2026-11-22
- FDA Device
- Yes
Countries
- United States
- Australia
- Austria
- Belgium
- Canada
- France
- Spain
- Switzerland
Study Locations
More Related Trials
-
Assessment of Lung Transplant Recipients Within The Scope of International Classification of Functioning, Disability and Health
NCT05376605 ·Status: COMPLETED
-
Transbronchial Biopsies With Cryoprobe in Patients With Lung Transplantation.
NCT03090581 ·Status: UNKNOWN ·Phase: NA
-
An Evaluation of Remote Care (Questionnaire+Hybrid) in Patients Who Are Post-lung Transplant
NCT05916495 ·Status: COMPLETED ·Phase: NA
-
Identifying Genetic Characteristics That Increase Risk of Primary Graft Dysfunction Following Lung Transplantation
NCT00457847 ·Status: RECRUITING
-
Pilot Study to Assess Safety and Feasibility of Normothermic Machine Preservation In Human Liver Transplantation
NCT02515708 ·Status: COMPLETED ·Phase: NA
-
Exhaled Breath Particles in Lung Transplantation
NCT05375149 ·Status: RECRUITING
-
Trajectories of FEV1 After Lung Transplantation
NCT05934617 ·Status: ENROLLING_BY_INVITATION
-
4DX Functional Lung Imaging in the Diagnosis of Chronic Lung Allograft Dysfunction After Lung Transplantation
NCT04892719 ·Status: COMPLETED ·Phase: NA
-
Prognosis of Lung Transplant Candidates
NCT00905463 ·Status: UNKNOWN
-
Impact of Cold Ischemia on Pulmonary Endothelial Dysfunction in Ex-vivo Pulmonary Reconditioning
NCT03987113 ·Status: COMPLETED
-
Diagnostic and Prognostic Biomarkers of Transplant Dysfunction in the Context of Lung Transplantation
NCT04837339 ·Status: RECRUITING ·Phase: NA
-
Optimizing Long-term Survival in Organ Transplantation: From Physiopathology to Optimized Patient Management
NCT03997253 ·Status: RECRUITING ·Phase: NA
-
Optimization of Donor-Recipient Matching in Lung Transplantation
NCT05195853 ·Status: UNKNOWN
-
Identification of Patient Important Outcomes in Lung Transplantation
NCT06066229 ·Status: UNKNOWN
-
Conventional Laparoscopic Versus Laparoendoscopic Single Site Donor Nephrectomy in Living Donor Kidney Transplantation
NCT01236326 ·Status: COMPLETED ·Phase: NA
-
Primary Graft Dysfunction Score in Lung Transplantation
NCT03276403 ·Status: UNKNOWN
-
Sleep Disordered Breathing and Lung Transplantation
NCT01179087 ·Status: UNKNOWN
-
Transbronchial Cryobiopsy in Lung Transplant Patients
NCT03090594 ·Status: UNKNOWN ·Phase: NA
-
Sleep-disordered Breathing After Solid Organ Transplantation
NCT03142022 ·Status: RECRUITING
-
Prospective Multicenter Research on Donor and Recipient Management Strategies to Improve Lung Transplant Outcomes
NCT06399302 ·Status: RECRUITING
-
The Effect of Intraoperative Arterial Oxygen Pressures on Early Post-Operative Patient and Graft Survival in Living Donor Kidney Transplantation
NCT04420897 ·Status: COMPLETED
-
Evaluation of Diaphragmatic Function After Bi-pulmonary Transplantation
NCT03977597 ·Status: UNKNOWN
-
Association Between Renal Regional Oxygen Saturation Measured by Near-InfraRed Spectroscopy and Postoperative Renal Failure After Lung Transplantation Surgery: A Pilot Study
NCT05836922 ·Status: RECRUITING
-
Cytokine Adsorption in Lung Transplantation
NCT05242289 ·Status: COMPLETED ·Phase: NA
-
Prospective Observational Pilot Study of LMWH Versus UFH as ECMO Anticoagulation in Lung Transplantation
NCT06868823 ·Status: RECRUITING