10°C vs 4°C Lung Preservation RCT

NCT05898776 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 317

Last updated 2026-03-19

No results posted yet for this study

Summary

Despite lung transplantation (LTx) being the most effective treatment for end-stage lung disease, its success rate is lower than that of other solid organ transplantations. Primary graft dysfunction (PGD) is the most common post-operative complication and a major factor in early mortality and morbidity, affecting \~25% of lung transplant patients. Induced by ischemia reperfusion, PGD represents a severe and acute lung injury that occurs within the first 72 hours after transplantation, and has a significant impact on short- and long-term outcomes, and a significant increase in treatment costs. Any intervention that reduces the risk of PGD will lead to major improvements in short- and long-term transplant outcomes and health care systems.

One of the main strategies to reduce the risk and severity of post-transplant PGD is to improve pre-transplant donor lung preservation methods. In current practice, lung preservation is typically performed by cold flushing the organ with a specialized preservation solution, followed by subsequent hypothermic storage on ice (\~4°C). This method continues to be used and applied across different organ systems due to its simplicity and low cost. Using this method for the preservation of donor lungs, the current maximum accepted preservation times have been limited to approximately 6-8h. While the goal of hypothermic storage is to sustain cellular viability during ischemic time through reduced cellular metabolism, lower organ temperature has also been shown to progressively favor mitochondrial dysfunction. Therefore, the ideal temperature for donor organ preservation remains to be defined and should maintain a balance between avoidance of mitochondrial dysfunction and prevention of cellular exhaustion. In addition to that, safe and longer preservation times can lead to multiple advantages such as moving overnight transplants to daytime, more flexibility to transplant logistics, more time for proper donor to recipient matching etc.

Building on pre-clinical research suggesting that 10°C may be the optimal lung storage temperature, a prospective, multi-center, non-randomized clinical trial was conducted at University Health Network, Medical University of Vienna and Puerta de Hierro Majadahonda University Hospital. Donor lungs meeting criteria for direct transplantation and with cross clamp times between 6:00pm - 4:00am were intentionally delayed to an earliest allowed start time of 6:00am and a maximum preservation time from donor cold flush to recipient anesthesia start time of 12 hours. Lungs were retrieved and transported in the usual fashion using a cooler with ice and transferred to a 10°C temperature-controlled cooler upon arrival to transplant hospital until implantation. The primary outcome of this study was incidence of Primary Graft Dysfunction (PGD) Grade 3 at 72h, with secondary endpoints including: recipient time on the ventilator, ICU Length of Stay (LOS), hospital LOS, 30-day survival and lung function at 1-year. Outcomes were compared to a contemporaneous conventionally transplanted recipient cohort using propensity score matching at a 1:2 ratio. 70 patients were included in the study arm. Post-transplant outcomes were comparable between the two groups for up to 1 year. Thus, intentional prolongation of donor lung preservation at 10°C was shown to be clinically safe and feasible.

In the current study design, the investigators will conduct a multi-centre, non-inferiority, randomized, controlled trial of 300 participants to compare donor lung preservation from the time of explant to implant at \~10°C in X°Port Lung Transport Device (Traferox Technologies Inc.) vs a standard ice cooler. When eligible donor lungs become available for a consented recipient, the lungs will be randomized to undergo a preservation protocol using either 10°C (X°Port Lung Transport Device, Traferox Technologies Inc.) or standard of care. The primary outcome of the study is incidence of ISHLT Primary Graft Dysfunction Grade 3 at 72 hours. Post-transplant outcomes will be followed for one year.

Conditions

  • Lung Transplant
  • Organ Preservation

Interventions

DEVICE

Lung transplantation after 10°C donor lung preservation

When suitable donor lungs become available for a, eligible, consented recipient and meet criteria to go straight to transplantation, the lungs randomized to 10°C preservation will be stored, transported and preserved in the X°Port Lung Transport Device (Traferox Technologies Inc.) until implant with a maximum time of 12 hours between the donor and recipient surgeries.

DEVICE

Lung transplantation after standard ice cooler donor lung preservation

When suitable donor lungs become available for a, eligible, consented recipient and meet criteria to go straight to transplantation, the lungs randomized to standard preservation will be will be stored, transported and preserved in an ice cooler (\~4°C, standard of care) until implant with a maximum time of 6 hours between the donor and recipient surgeries.

Sponsors & Collaborators

  • Medical University of Vienna

    collaborator OTHER
  • Vanderbilt University

    collaborator OTHER
  • Puerta de Hierro University Hospital

    collaborator OTHER
  • University of California, San Francisco

    collaborator OTHER
  • Centre Hospitalier Universitaire Vaudois

    collaborator OTHER
  • Mayo Clinic

    collaborator OTHER
  • St Vincent's Hospital, Sydney

    collaborator OTHER
  • University of Texas Southwestern Medical Center

    collaborator OTHER
  • Corewell Health West

    collaborator OTHER
  • University of Miami

    collaborator OTHER
  • University Hospital of Leuven Leuven

    collaborator OTHER
  • Centre hospitalier de l'Université de Montréal (CHUM)

    collaborator OTHER
  • University Hospital, Zürich

    collaborator OTHER
  • Dignity Health

    collaborator OTHER
  • Hospital Universitario 12 de Octubre

    collaborator OTHER
  • Marie Lannelongue Hospital, Le Plessis Robinson, France

    collaborator UNKNOWN
  • University Health Network, Toronto

    lead OTHER

Principal Investigators

  • Elliot Wakeam, MD MPH · University Health Network, Toronto

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2023-06-09
Primary Completion
2025-11-24
Completion
2026-11-22
FDA Device
Yes

Countries

  • United States
  • Australia
  • Austria
  • Belgium
  • Canada
  • France
  • Spain
  • Switzerland

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05898776 on ClinicalTrials.gov