Clinical Application of Electrical Impedance Tomography for Individual Adjustment of Ventilator Settings
NCT02703012 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2019-04-19
Summary
First clinical application of an algorithm for individual adjustment of ventilator settings using electrical impedance tomography.
Conditions
- ARDS
Interventions
- OTHER
-
Adjustment of ventilator settings by EIT
Diagnostic maneuvers (change in tidal volume, recruitment maneuvers) will be performed to detect overdistention, tidal recruitment and recruitability. Tidal volume will be reduced if overdistention is detected by EIT. Positive end-expiratory pressure will be increased if tidal recruitment or recruitability are detected.
Sponsors & Collaborators
-
University Hospital Schleswig-Holstein
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2016-01-31
- Primary Completion
- 2019-04-04
- Completion
- 2019-04-04
Countries
- Germany
Study Locations
More Related Trials
-
Monitorings the Physiological Mechanism of Airway Pressure Release Ventilation in ARDS Patients by EIT
NCT05406427 ·Status: UNKNOWN
-
Pressure Opening With Electrical Impedance Tomography
NCT05825534 ·Status: UNKNOWN ·Phase: NA
-
Ultra-protective Ventilation Monitored by Electrical Impedance Tomography in Patients With Severe Acute Respiratory Distress Syndrome on Veno-venous ECMO
NCT05717218 ·Status: RECRUITING ·Phase: NA
-
Electrical Impedance Tomography-Based Prognostic Model for ARDS
NCT06967207 ·Status: RECRUITING
-
Effect of Electric Impedance Tomography-Guided PEEP Titration
NCT05736185 ·Status: COMPLETED ·Phase: NA
-
Personalized Ventilation Based on Ventilation-perfusion Mismatch and Lung Recruitability
NCT06430554 ·Status: RECRUITING
-
Application of Indicator Based-electrical Impedance Tomography Method Assess Lung Regional Perfusion in ICU Patients
NCT04081142 ·Status: COMPLETED
-
EIT-Guided Ventilator Settings in AHRF
NCT06936618 ·Status: RECRUITING ·Phase: NA
-
Evaluation of the Diagnostic Performance of Electrical Impedance Tomography to Detect Situations at Risk of Lesions Induced by Conventional Mechanical Ventilation in ARDS
NCT02896673 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Optimal PEEP Determination Guided by EIT and Conventional Protective Ventilation Tool in ARDS Patients
NCT03498807 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Optimal PEEP Determination Guided by EIT and G5 Device in Moderate and Severe ARDS Patients
NCT03112512 ·Status: COMPLETED ·Phase: NA
-
Effect of EIT-guided PEEP Titration on the Prognosis of Patients with Moderate to Severe ARDS
NCT05207202 ·Status: COMPLETED ·Phase: NA
-
Combining Electrical Impedance Tomography and Thoracic Ultrasound Toinvestigate Dynamic Changes
NCT06958770 ·Status: NOT_YET_RECRUITING
-
Automated Analysis of EIT Data for PEEP Setting
NCT03653806 ·Status: COMPLETED
-
Electrical Impedance Tomography for Quantification of Pulmonary Edema in Acute Respiratory Distress Syndrome Patients
NCT02870894 ·Status: UNKNOWN
-
Electrical Impedance Tomography: Collapse in Dependent Areas as a Predictor of Response to Prone Position Ventilation in COVID-19 Acute Respiratory Distress Syndrome
NCT04603755 ·Status: COMPLETED
-
Incremental and Decremental PEEP Titration by Diverse Strategies in Subjects with ARDS: a Prospective Physiological Study
NCT06808438 ·Status: COMPLETED
-
Strategies to Optimize Positive End-expiratory Pressure (PEEP) in Patients With Acute Lung Injury
NCT01326208 ·Status: UNKNOWN ·Phase: PHASE2
-
Comparison of Different PEEP Titration Strategies Using Electrical Impedance Tomography in Patients With ARDS
NCT04247477 ·Status: COMPLETED ·Phase: NA
-
Determine the Effect of Prone Positioning in Adults With ARDS by Electrical Impedance Tomography
NCT04725227 ·Status: UNKNOWN
-
Regional Lung Opening and Closing Pressures in Patients With Acute Lung Injury
NCT01107847 ·Status: UNKNOWN ·Phase: NA
-
Lung EIT Image Guide Ventilation in ARDS
NCT07309783 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
EIT Assessment of Overdistension in ARDS Patients in Prone Position
NCT06536543 ·Status: RECRUITING
-
The Impact of PEEP-guided Electrical Impedance Tomography on Oxygenation and Pulmonary Mechanics in Moderate-to-severe ARDS
NCT06733168 ·Status: RECRUITING ·Phase: NA
-
Titration of PEEP During Mechanical Ventilation in Patients With ARDS Using Electrical Impedance Tomography.
NCT02596178 ·Status: WITHDRAWN ·Phase: NA