Comparing the Diagnostic Adequacy of 25-gauge Fork-tip, Franseen and Reverse-bevel Type Needles in Endoscopic Ultrasound Guided Tissue Acquisition
NCT05434247 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 178
Last updated 2022-06-27
Summary
Endoscopic ultrasound guided fine needle aspiration (EUS-FNA) and fine needle biopsy (EUS-FNB) are well established techniques for the acquisition of tissue to classify a number of lesions of the gastrointestinal tract and surrounding organs. These include pancreatic, lymphoid, subepithelial and other abdominal lesions. Historically, FNA was the sole available modality used to obtain cytological samples for analysis. The major shortcoming of this technique is the lack of a histological tissue core.
In recent years attention has turned to optimizing needle design to improve sample quality. New needles have been developed which aim to obtain a core of tissue with preserved architecture.
These needles include the first generation Reverse-bevel Echo Tip® HD ProCore™ (Wilson-Cook Medical Inc., Winston-Salem, NC, United States), and the second generation Fork-tip SharkCore™ (Medtronic Inc., Sunnyvale, CA, United States) and Franseen Acquire™ (Boston Scientific, Marlborough, MA, United States).
Currently there are a paucity of studies comparing the performance of these needles, and only two of these are prospective randomized controlled trials. Real world performance of these needles has seldom been reported, with only one RCT including non-pancreatic masses in their analysis.
The investigators hypothesize that second generation needles have equivalent or better diagnostic performance than the prior first-generation needle.
To test this, the investigators aim to conduct a prospective randomized controlled study comparing the performance of Fork-tip and Franseen needles for the sampling of pancreatic, subepithelial, lymphoid and other abdominal or mediastinal lesions. They also aim to include a retrospective control arm of consecutive cases using the first-generation Reverse-bevel needle.
The investigatora aim to assess the diagnostic yield of each needle, as well as number of needle passes used, and specimen quality.
Conditions
- Biopsy, Needle
Interventions
- DEVICE
-
Needle choice
The type of needle use was the only intervention
Sponsors & Collaborators
-
Princess Alexandra Hospital, Brisbane, Australia
lead OTHER
Principal Investigators
-
Alexander Huelsen, MD · QLD Health
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 16 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-09-01
- Primary Completion
- 2019-09-01
- Completion
- 2020-09-01
- FDA Device
- Yes
Countries
- Australia
Study Locations
More Related Trials
-
EUS-guided Fine Needle Biopsy With a New Core Histology Needle Versus Conventional Fine Needle Aspiration
NCT01774162 ·Status: COMPLETED ·Phase: NA
-
The Use of FNA and FNB in the Optimization of EUS-assisted Tissue Sampling
NCT02360839 ·Status: COMPLETED ·Phase: NA
-
Prospective Trial of EUS-FNA Versus EUS-FNB Using a Novel Core Biopsy Needle
NCT01769248 ·Status: COMPLETED ·Phase: NA
-
A Clinical Trial With a New Needle Device Comparing Two Needles for EUS_FNA of Solid Lesions.
NCT02246322 ·Status: UNKNOWN ·Phase: NA
-
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses
NCT01576497 ·Status: COMPLETED ·Phase: PHASE3
-
EUS-FNB for Solid Pancreatic Lesions: Side-fenestrated Vs Fork-tip Needle
NCT03622229 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Ultrasonography (EUS) Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles
NCT01543282 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Efficacy Of 3 EUS-FNB Techniques
NCT05825729 ·Status: RECRUITING ·Phase: PHASE4
-
Multicentered Prospective Randomized Controlled Trial For Solid Pancreatic Lesions
NCT04841616 ·Status: UNKNOWN ·Phase: NA
-
Prospective Study FNB, Is It Time To Abandon Cytological Assessment
NCT04165018 ·Status: COMPLETED
-
Comparison of Two Needle Aspiration Techniques for Endoscopic Ultrasound-guided Fine Needle Aspiration (EUS-FNA) in Solid Pancreatic Lesions
NCT01936467 ·Status: COMPLETED ·Phase: PHASE3
-
EUS-guided Fine Needle Aspiration (EUS-FNA) Versus EUS-guided Fine Needle Biopsy (EUS-FNB) for Diagnosis of Subepithelial Tumors
NCT02943837 ·Status: WITHDRAWN ·Phase: NA
-
Prospective Comparison of Diagnostic Accuracy Between Contrast-enhanced Harmonic and Conventional EUS-guided Fine-needle Biopsy in Solid Pancreatic Lesions
NCT04924725 ·Status: COMPLETED ·Phase: NA
-
Evaluation of EUS-Guided 22 Gauge Core Biopsy Versus Fine-needle Aspiration for Suspected Pancreatic Neoplasms
NCT01673334 ·Status: COMPLETED ·Phase: PHASE4
-
Diagnostic Yield of 20-gauge Procore Needle for EUS-guided FNA Biopsy in Solid Pancreatic Lesions
NCT02920944 ·Status: COMPLETED ·Phase: NA
-
SharkCore Versus Acquire FNB
NCT03672032 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Yield of FNA Needle and FNB Needle for Autoimmune Pancreatitis
NCT03753815 ·Status: UNKNOWN ·Phase: NA
-
Comparing a 25G EUS Fine Needle Aspiration (FNA) Device With a 20G EUS
NCT02167074 ·Status: COMPLETED ·Phase: NA
-
Yield of Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) With and Without the Use of a Stylet in the Biopsy Needle
NCT01241799 ·Status: COMPLETED ·Phase: NA
-
Novel Crown-cut Biopsy Needle (FNB) vs Standard Aspiration Needle (FNA) for EUS-guided Diagnosis of SPLs
NCT04687410 ·Status: UNKNOWN ·Phase: NA
-
22G FNA Needle vs. 22G ProCore Needle
NCT01394159 ·Status: COMPLETED ·Phase: NA
-
Comparation Between Needles for EUS-guided Sampling of Solid Pancreatic Lesions
NCT04877340 ·Status: UNKNOWN ·Phase: NA
-
Contrast-Enhanced Harmonic vs Conventional EUS-guided Fine Needle Biopsy for Solid Pancreatic Lesions: Randomized Controlled Trial
NCT04924751 ·Status: UNKNOWN ·Phase: NA
-
Endoscopic Ultrasound (EUS)-Guided Fine Needle Aspiration (FNA) With Rapid On-site Evaluation (ROSE) of Cytopathology vs. EUS-guided Fine Needle Biopsy (FNB) Alone in the Diagnosis of Pancreatic Solid Lesions
NCT03435588 ·Status: COMPLETED ·Phase: NA
-
A Randomized Controlled Trial Of Endoscopic Ultrasound-Guided Fine-Needle Aspiration With And Without A Stylet
NCT01213290 ·Status: UNKNOWN ·Phase: NA