Headgear Accessory for Exercise-Induced Laryngeal Obstruction Studies
NCT05314478 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2024-11-08
Summary
Exercise-induced laryngeal obstruction (EILO) is a condition in which the larynx, or voice box, narrows during high-intensity exercise, and is often mis-diagnosed. A test called a Continuous Laryngoscopy during Exercise (CLE) test can be performed, where a flexible camera is inserted through the nose and positioned at the back of the throat. While the patient exercises, the camera image can be used to identify the presence of EILO.
During the CLE test it is important that the part of the camera that remains outside the body is held securely in position near the forehead so that a clear and stable image is obtained using a headgear to secure the camera to the patient's head.
There are no headgears available on the market, so we have designed and manufactured one called HALOS (Headgear Accessory for Exercise-Induced Laryngeal Obstruction Studies).
This study is to ensure that HALOS is suitable for use, and to check we have understood and minimised the risks associated with the headgear. The headgear can then be used routinely within the Trust, improving the care that offered to patients.
We will recruit 30 male or female participants who need to undergo a CLE test. The study will be conducted at Broadgreen Hospital, Liverpool, UK. Before the CLE test, participants will attend a screening appointment to discuss the procedure. There will be no follow-up appointments.
During the CLE test, the participants will wear the HALOS headgear while exercising, and the clinician will monitor the image from the camera for signs of EILO. After the test, participants will be asked how tolerable the headgear was, and if they have any concerns about any aspect of it. The clinician will also record how clear and stable the camera image was, how easy it was to use, and any concerns about any aspect of it.
Conditions
- Exercise-Induced Laryngeal Obstruction
Interventions
- DEVICE
-
Continuous laryngoscopy during exercise test using the HALOS headgear
The participant will undergo the CLE test following standard clinical practice. The order of events of the aspects of the investigation related to the headgear will be: 1. The headgear is prepared for use. 2. The headgear is fitted onto the participant's head. 3. The endoscope is inserted into the participant. 4. The endoscope is fitted onto the headgear. 5. The CLE test is carried out. 6. The endoscope is removed from the headgear. 7. The endoscope is removed from the participant. 8. The headgear is removed from the participant. 9. The headgear is cleaned and stored.
Sponsors & Collaborators
-
Liverpool University Hospitals NHS Foundation Trust
lead OTHER_GOV
Principal Investigators
-
Tristan Payne · Liverpool University Hospitals NHS Foundation Trust
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-03-24
- Primary Completion
- 2023-08-25
- Completion
- 2023-08-25
Countries
- United Kingdom
Study Locations
More Related Trials
-
Comparison of Airway Intubation Devices When Using a Biohazard Suit
NCT01924559 ·Status: COMPLETED ·Phase: NA
-
Laryngeal View With Videolaryngoscopy
NCT01635179 ·Status: COMPLETED ·Phase: NA
-
GlideScope Groove vs. Standard GlideScope: A Non-inferiority Study
NCT01489605 ·Status: WITHDRAWN ·Phase: NA
-
High Flow Oxygen in Patients Undergoing Suspension Laryngoscopy Under General Anesthesia
NCT03472118 ·Status: TERMINATED ·Phase: NA
-
Comparison of GlideScope Videolaryngoscopy to Direct Laryngoscopy for Nasal Intubation
NCT00400972 ·Status: COMPLETED ·Phase: NA
-
Video-Laryngoscope Alone or With Bronchoscope for Predicted Difficult Intubation
NCT03080896 ·Status: COMPLETED ·Phase: NA
-
Comparing iView Video Laryngoscope in the Emergency Department
NCT04907695 ·Status: COMPLETED
-
Comparison Between the Fastrach and CTrach Laryngeal Mask Airway
NCT00814775 ·Status: TERMINATED ·Phase: NA
-
GlideScope Videolaryngoscopy in Patients With Reduced Mouth Opening
NCT04174833 ·Status: COMPLETED
-
Comparative Evaluation of Periglottic Airway Devices With Performed Shape
NCT05639439 ·Status: UNKNOWN ·Phase: NA
-
The Use of Novel us Device (Jetguide) to Measure the Distance to the Roof of the IAC (Inferior Alveolar Canal)
NCT01505335 ·Status: UNKNOWN
-
Endotracheal Intubation Using Videolaryngoscopy Versus Conventional Direct Laryngoscopy
NCT04701762 ·Status: COMPLETED ·Phase: NA
-
Evaluating the Use of a Device Called Impulse Oscillometry in Participants With Vocal Cord Disorders or Asthma
NCT05246930 ·Status: COMPLETED
-
Combined Use of Glidescope With Fiber Optic Broncscopy Versus Fiber Optic Alone in Difficult Intubation
NCT05751590 ·Status: COMPLETED ·Phase: NA
-
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754 ·Status: COMPLETED ·Phase: NA
-
Glossopharyngeal Nerve Blockade for Awake Videolaryngoscope Assisted Endotracheal Intubation in the Morbidly Obese
NCT01791439 ·Status: UNKNOWN ·Phase: NA
-
Soft Mist Spray Device for Airway Anaesthesia During Awake Videolaryngoscopy
NCT05478122 ·Status: COMPLETED ·Phase: NA
-
Vidéolaryngoscopy Study of the LPEC in Obese Patients
NCT04128982 ·Status: COMPLETED
-
Fibreoptic Intubation With and Without Sellick´s Maneuver
NCT01357824 ·Status: COMPLETED
-
Aspiration of Subglottic Secretions Using Hi-Lo Evac Endotracheal Tube: Tube Size and Incidence of Suction Lumen Dysfunction
NCT00450476 ·Status: UNKNOWN
-
Video Laryngoscope, New Intubation Device
NCT02095470 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Comparison of Office-based KTP and CO2 Laser Outcomes in Patients With Vocal Cord Lesions.
NCT04575142 ·Status: COMPLETED ·Phase: NA
-
A Comparative Study of the Air-Q ILA and the ILMA for Ventilation and Intubation
NCT01209559 ·Status: WITHDRAWN
-
Glottis Visualization in Different Lifting Methods
NCT05967338 ·Status: COMPLETED
-
VIDEOLARYNGOSCOPY STUDY OF THE LPEC
NCT04126356 ·Status: COMPLETED