Biological Markers for Post-Traumatic Stress Disorder

NCT05213858 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 300

Last updated 2024-02-06

No results posted yet for this study

Summary

The current study aims to evaluate the sensitivity and specificity of a combination of various objective biomarkers for the diagnosis of PTSD.

Conditions

  • Post Traumatic Stress Disorder

Interventions

DIAGNOSTIC_TEST

CAPS questionnaire

PTSD diagnosis and severity will be done using the CAPS-5 questionnaire.

DIAGNOSTIC_TEST

Beck Depression Inventory

depression symptoms will be measured by the BDI-II. The BDI-II consists of 21 items and uses a 0 to 3 severity scale. Total scores range from 0 to 63, with higher scores indicating more severe depression.

DIAGNOSTIC_TEST

The Fibromyalgia Impact Questionnaire

The FIQ was developed from information gathered from patient reports, functional status instruments and clinical observations. This instrument measures physical functioning, work status (missed days of work and job difficulty), depression, anxiety, morning tiredness, pain, stiffness, fatigue and well-being over the past week.

DIAGNOSTIC_TEST

The Pittsburgh Sleep Quality Index

sleep patterns will be measured using the PSQI. This index assesses the quality and patterns of sleep in adults. It differentiates "poor" from "good" sleep quality by measuring seven components: subjective sleep quality, sleep latency, sleep duration, habitual sleep efficiency, sleep disturbances, the use of sleeping medications and daytime dysfunction over the last month. Items are rated using a 0 to 3 scale. The component scores are summed to produce a global score (range 0 to 21). Higher scores indicate worse sleep quality.

DIAGNOSTIC_TEST

Depression, Anxiety and Stress Scale-21 items

The DASS-21 is a three-scale self-report questionnaire designed to measure the emotional state of depression, anxiety and stress. Each scale contains 7 items, divided into subscales with similar content. Scores range between 0 and 21 in each subcategory.

DIAGNOSTIC_TEST

Traumatic Events Questionnaire

The TEQ examines experiences of traumatic events (e.g. sexual abuse, accidents and crime) that are considered potential triggers of PTSD symptoms. To assess trauma intensity, respondents provide information for each event that was experienced, as well as their age at the time of the event. The items are measured on a 9-point Likert scale from "not at all" to "severely/extremely". The TEQ has previously been used in Israel.

DIAGNOSTIC_TEST

Clinician Administered Dissociative States Scale

The CADSS is a 28-item structured clinical interview to assess state dissociation.

DIAGNOSTIC_TEST

A diary will be used for seven consecutive nights

A diary will be used for seven consecutive nights for the evaluation of: * Mean sleep latency * The number and duration of awakenings. * Subjective total sleep time * Subjective wake after sleep onset * Sleep efficiency

DIAGNOSTIC_TEST

MRI

Brain imaging will include DTI and resting state for structural and functional MRI scanning. Images will be acquired on MAGNETOM Vida 3T Scanner, configured with 64-channel receiver head coils (Siemens Healthcare, Erlangen, Germany) at the Department of Radiology at Shamir Medical Center.

DIAGNOSTIC_TEST

Functional brain imaging

Functional magnetic resonance imaging (fMRI) is widely used to study the operational organization of the human brain. This technology measures brain activity by detecting changes associated with blood oxygenation, using blood-oxygen-level-dependent imaging (BOLD) contrast.

DIAGNOSTIC_TEST

EEG analysis

EEG will be obtained using a point-of care device that consists of an EEG-Sense Headset, EEG-Sense Single-Use brush sensors, a pneumatic sensor positioning mechanism, EEG sampling electronics and software. The EEG-Sense Headset is an EEG electrode positioning system that quickly places electrodes in a uniform and consistent manner, to transfer electrophysiological EEG signals from an individual to a suitable EEG data collection device. The device is nonsterile, non-invasive and non-radiation emitting, and was developed for use in healthcare facilities and hospitals. Typical set-up and procedure time is several minutes. The device does not contain biologics, drugs, coatings or any claim of sterility. The EEG-Sense Single-Use brush sensors are made from well-established medical-grade materials; the Headset is made from Nylon 101. Electronic components and harnesses are embedded between two layers of nylon and are attached to each electrode port.

DIAGNOSTIC_TEST

Autonomic nervous system monitors

Data will be collected using Empatica's E4 wristband. Each of the study participants will wear the wristband for 7 days. Data collected from the band will include: ACC - Data from 3-axis accelerometer sensor in the range \[-2g, 2g\]. (sampled at 32 Hz) BVP - Data from photoplethysmography (PPG). (sampled at 64 Hz) EDA - Data from the electrodermal activity sensor in μS. (sampled at 4 Hz) IBI - Inter-beat intervals. (intermittent output with 1/64 second resolution) TEMP - Data from temperature sensors, expressed in degrees on the Celsius (°C) scale. (sampled at 4 Hz)

Sponsors & Collaborators

  • Assaf-Harofeh Medical Center

    lead OTHER_GOV

Principal Investigators

  • keren doenyas-barak, md · sagol center for hyperbaric medicine

Eligibility

Min Age
20 Years
Max Age
60 Years
Sex
MALE
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2022-01-01
Primary Completion
2025-12-01
Completion
2026-01-01

Countries

  • Israel

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05213858 on ClinicalTrials.gov