Bio Electrical Impedance Analysis to Monitor Fluid Status During Deresuscitation Strategy in Continuous Renal Replacement Therapy
NCT05160467 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 23
Last updated 2022-01-28
Summary
Fluid overload is a poor prognostic factor in patients undergoing continuous renal replacement therapy in critical care. A strategy of active fluid removal by net ultrafiltration (UFnet) is one of the means to correct it. However, fluid overload is difficult to quantify: weight variations or cumulative fluid balance are easy to use but imprecise and not concordant markers, while reference methods such as isotope dilution are not adapted to daily practice.
Bio electrical impedance analysis (BIA) is used to estimate body composition, including hydration. It is a non-invasive, rapid and painless measurement. It is commonly used in chronic intermittent haemodialysis to estimate dry weight and guide fluid removal, with a demonstrated impact on blood pressure control. This analysis is feasible in the ICU. Fluid overload as defined by BIA correlates with mortality, most notably in acute renal failure and during continuous renal replacement therapy.
We routinely perform multifrequency segmental BIA (InBody S10, Seoul, Korea) in patients with fluid overload in our intensive care department. Since February 2021, we have implemented a protocol to systematically correct fluid overload by inducing negative fluid balance with UFnet in a manner appropriate to tissue perfusion. In this context, we systematically perform a BIA analysis on the day of the beginning of the fluid balance negativation and then every 48 hours during the first five days.
We would like to evaluate the relevance of BIA monitoring in these patients by comparing it to other parameters of evaluation of the volume status usually used.
Conditions
- Fluid Overload
Interventions
- DIAGNOSTIC_TEST
-
Segmental multi-frequency bio electrical impedance analysis
A segmental (eight-polar) multi-frequency bio electrical impedance analysis (Inbody S10, Seoul, Korea) is carried out at the initiation of the deresuscitation strategy, at day 1, 3 and 5, in lying posture with touch type electrodes. Raw and derived parameters are recorded. The measurement is performed 5 times for the first measurement and then one time at day 1, 3 and 5. Measurement error is defined by the manufacturer as: reversed Impedance in different segment all between 5-500kHz; impedance over 50Ω in trunk, or over 700Ω in limb; sudden drop of impedance in trunk (more than 10Ω), or in limb (more than 50Ω). If it occurs, measurement is carried out three times maximum after solving potential technical issues to obtain a valid analysis.
Sponsors & Collaborators
-
Hospices Civils de Lyon
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-03-15
- Primary Completion
- 2021-11-15
- Completion
- 2022-01-31
Countries
- France
Study Locations
More Related Trials
-
Effects of Fluid Balance Control in Critically Ill Patients
NCT02765009 ·Status: COMPLETED ·Phase: NA
-
Ultrasound and Clinical Approach for the Dynamic Assessment of Fluid Tolerance in the Intensive Care Unit
NCT06415916 ·Status: RECRUITING
-
Timing and Dose of Fluid Deresuscitation in Critically Ill Patients
NCT07275658 ·Status: RECRUITING
-
Proactive Prescription-based Fluid Management vs Usual Care in Critically Ill Patients on Kidney Replacement Therapy
NCT05473143 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of Hydration Status Using Bioelectrical Impedance Vector Analysis
NCT02936440 ·Status: COMPLETED
-
Investigation of Fluid- and Electrolyte Balance in Post Cardiac-surgery Patients
NCT02914782 ·Status: COMPLETED
-
Tailored Hydration Based on Bioimpedance Analysis for Prevention of Contrast Induced Acute Kidney Injury
NCT04215042 ·Status: UNKNOWN ·Phase: NA
-
Comparison of 5% Nacl and 10% NaHCO3 As Contrast Agents for Lung Perfusion with EIT
NCT06868810 ·Status: COMPLETED ·Phase: NA
-
End-expiratory Occlusion Test and Prediction of Preload Dependence
NCT05874531 ·Status: COMPLETED
-
BIA-Guided vs. Conventional Fluid Resuscitation in ICU Patients
NCT07142083 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
BIA Guided-fluid Management in Postinjury Open Abdomen
NCT03466684 ·Status: COMPLETED ·Phase: NA
-
Fluid Responsiveness Prediction at the Bedside
NCT00721604 ·Status: COMPLETED
-
Fluid Balance Guided by Modified Venous Excess Ultrasonography Versus Standard Care in Patients With Acute Kidney Injury Receiving Continuous Renal Replacement Therapy
NCT07346118 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
CVP-guided Aquapheresis for the Treatment of Acute Congestion in Heart Failure
NCT02079259 ·Status: COMPLETED
-
Once Versus Twice Daily Electrolyte Monitoring in CHF
NCT02497742 ·Status: COMPLETED ·Phase: NA
-
Hemodynamic Optimization By Non-Invasive Determination Of Cardiac Output In Critically Ill Patients
NCT01309724 ·Status: COMPLETED ·Phase: NA
-
Cumulative Fluids Balance and Ventilator Associated Events
NCT05556694 ·Status: COMPLETED
-
Intrarenal Venous Flow Change During Fluid Removal in Critically Ill Patients: A Prospective Exploratory Study
NCT06216119 ·Status: COMPLETED
-
Fluid Responsiveness Prediction During Prone Position
NCT05898269 ·Status: RECRUITING ·Phase: NA
-
Impact of Rational Control of Fluid Balance in the Intensive Care Unit
NCT02345681 ·Status: COMPLETED ·Phase: PHASE3
-
Comparing Fluid Responsiveness Assessment Methods in Patients With Impaired Consciousness
NCT06180902 ·Status: RECRUITING ·Phase: NA
-
Non-invasive Fluid Management
NCT02892799 ·Status: UNKNOWN ·Phase: NA
-
Fluid Management Surgical Patients in Intensive Care Unit.
NCT03455296 ·Status: COMPLETED ·Phase: NA
-
Volume Resuscitation in Cirrhosis With Sepsis Induced Hypotension
NCT05059795 ·Status: COMPLETED
-
Continuous Passive Paracentesis for Intra-abdominal Hypertension
NCT04322201 ·Status: UNKNOWN ·Phase: NA