Conduction System Pacing Optimized Therapy
NCT04905290 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2025-04-15
Summary
The purpose of the CSPOT study is to determine the best mode of cardiac resynchronization therapy (CRT) pacing for different populations of CRT patients, comparing traditional biventricular or left ventricular pacing (BiV), conduction system pacing (CSP)-only, and conduction system pacing optimized therapy (CSPOT) also known as a combination of conduction system pacing (CSP) and left ventricular (LV) pacing. Additionally, safety of the system will be assessed.
Conditions
Interventions
- DEVICE
-
Left ventricular coronary sinus (BiV) configuration
For subjects with a pacemaker, pacing of the left ventricular coronary sinus only. For subjects with a defibrillator, biventricular pacing of the left ventricular coronary sinus and the right ventricle. During the acute protocol, the five AV delays for this intervention include the default AV delay setting, default + 30 milliseconds (ms) AV delay, default + 60 ms AV delay, default - 30ms AV delay, default - 60ms AV delay. Patients with a defibrillator will receive two additional delays LV precedes default by 30ms and LV precedes default by 60ms.
- DEVICE
-
Conduction system pacing-only configuration
Conduction System Pacing (CSP) of the left bundle branch. During the acute protocol, the five AV delays for this intervention include the default AV delay setting, default + 30 milliseconds (ms) AV delay, default + 60 ms AV delay, default - 30ms AV delay, and default - 60ms AV delay.
- DEVICE
-
Conduction System Pacing Optimized Therapy (CSPOT) configuration
A combination of Left Ventricle pacing and Conduction System Pacing of the left bundle branch. During the acute protocol, the eight delays for this intervention include the default AV delay setting, default + 30 milliseconds (ms) AV delay, default + 60 ms AV delay, default - 30ms AV delay, default - 60ms AV delay, CSP precedes default by 30ms, LV precedes default by 30ms and LV precedes default by 60ms.
Sponsors & Collaborators
-
Medtronic Cardiac Rhythm and Heart Failure
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-11-27
- Primary Completion
- 2023-04-18
- Completion
- 2023-11-02
- FDA Device
- Yes
Countries
- United States
- Ireland
- Poland
- United Kingdom
Study Locations
More Related Trials
-
ECG Optimization of CRT: Evaluation of Mid-term Response
NCT01439529 ·Status: COMPLETED ·Phase: PHASE3
-
Optimization of CRT Using an ECG Vest
NCT02699944 ·Status: COMPLETED ·Phase: NA
-
Left Ventricular MultiSpot Pacing for CRT (iSPOT)
NCT01883141 ·Status: COMPLETED ·Phase: NA
-
Septal Mapping And Resynchronisation Therapy- (SMART) Study
NCT04595305 ·Status: COMPLETED ·Phase: NA
-
Optimal Programming to Improve Mechanical Indices, Symptoms and Exercise in Cardiac Resynchronization Therapy.
NCT00489177 ·Status: COMPLETED ·Phase: PHASE4
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
Cardiac Resynchronization Therapy Defibrillator Based Impedance Monitoring Study
NCT00500838 ·Status: COMPLETED ·Phase: NA
-
Conduction System Pacing vs Biventricular Pacing in Systolic Dysfunction and Wide QRS: Mortality, Heart Failure Hospitalization or Cardiac Transplant
NCT06105580 ·Status: RECRUITING ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Optimal Pacing Rate for Cardiac Resynchronization Therapy
NCT06445439 ·Status: RECRUITING ·Phase: NA
-
Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients
NCT04083690 ·Status: UNKNOWN ·Phase: NA
-
Optimisation of Cardiac Resynchronisation Therapy by Non-invasive Cardiac Output - The CHOICE2 Study
NCT01055210 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Cardiac Resynchronization Therapy (CRT) Using the Ovatio CRT Implantable Cardioverter-defibrillator (ICD) System
NCT00528320 ·Status: APPROVED_FOR_MARKETING
-
Cutaneous Heart Sounds Data Collection During Cardiac Resynchronization Therapy (CRT) Optimization Study
NCT01609985 ·Status: COMPLETED
-
Triple-site Biventricular Stimulation in the Optimization of CRT
NCT02350842 ·Status: COMPLETED ·Phase: NA
-
Response of Cardiac Resynchronization Therapy Optimization With Ventricle to Ventricle Timing in Heart Failure Patients
NCT00187200 ·Status: COMPLETED ·Phase: PHASE4
-
Optimizing Cardiac Resynchronization
NCT00205192 ·Status: COMPLETED
-
Comparing Rate Response With CLS Versus Accelerometer ICD Settings in Heart Failure Patients With BIOTRONIK CRT-Ds
NCT02693262 ·Status: COMPLETED ·Phase: NA
-
Propensity-Matched Study of Cardiac Contractility Modulation Therapy in Heart Failure
NCT07209098 ·Status: RECRUITING
-
Investigational Device Exemption (IDE) Study for the Approval of Closed Loop Stimulation (CLS) and Cardiac Resyncronization Pacing Therapies (CRT) for the Treatment of Atrial Fibrillation (AF) With Ablate and Pace
NCT00356057 ·Status: TERMINATED ·Phase: NA
-
Post Approval Registry of Corox OTW, Endocardial, Left Ventricular Steroid Lead, Bipolar
NCT00810264 ·Status: COMPLETED
-
LVSP Based CRT vs. RVAP Based CRT
NCT05985408 ·Status: UNKNOWN ·Phase: NA
-
Conduction System Pacing International Registry (CONSPIRE)
NCT04831125 ·Status: COMPLETED
-
BIO|MASTER.CSP Study
NCT06620237 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Choosing the Right Pacing Mode in Heart Failure - The CHOICE Trial
NCT00875732 ·Status: COMPLETED ·Phase: NA