The Use of Pulmonary Hyperinflation With the Mechanical Ventilator in Cardiac Patients

NCT04583371 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50

Last updated 2020-10-12

No results posted yet for this study

Summary

Mechanical ventilation (MV) is used to reduce work and reverse or prevent fatigue of the respiratory muscles, decrease oxygen consumption and maintain gas exchange. In addition to the benefits given to patients undergoing MV, there is a high risk of accumulating bronchial secretions, related to pathology and / or therapeutic intervention. Pulmonary hyperinflation is widespread in patients in intensive care centers (ICUs) as a bronchial hygiene therapy, being used in 40% of 64 Australian ICUs as demonstrated by Dennis et al., Through contact with physical therapists. Mechanical hyperinflation associated with tracheal aspiration is able to increase the amount of secretion aspirated when compared to isolated aspiration in patients undergoing mechanical ventilation. To assess whether the pulmonary hyperinflation maneuver with the mechanical ventilator, compared to isolated tracheal aspiration, increases the removal of secretions. To evaluate whether the use of the pulmonary hyperinflation maneuver in the mechanical ventilator is hemodynamically stable through the collection in two moments of the variables of heart rate (HR), mean arterial pressure (MAP), peripheral saturation (SpO2), respiratory rate (RF) that will be analyzed from the postoperative unit's multiparametric monitor.

Evaluate the change in respiratory mechanics through collection in two moments after the mechanical hyperinflation technique through dynamic compliance (Cdyn), tidal air volume (VAC), peak pressure (Ppico). The population will consist of patients from the Post-Operative Unit (UPO), from the Institute of Cardiology, of both sexes, over 18 years old, mechanically ventilated and the sample consisting of 50 individuals. These will be submitted to the use of the pulmonary hyperinflation maneuver in the mechanical ventilator. Randomized crossover clinical trial.

Conditions

  • Heart Diseases

Interventions

OTHER

MECHANICAL PULMONARY HYPERINFLUATION

For basal aspiration, the patient will be placed in the supine position with the head elevated at 30º, will be submitted to a single aspiration with a size 12 probe (Mark Med), with a vacuum adjusted to -40cmH2O of pressure, with basic asepsis care being maintained for performing the technique. In the participants of the intervention group, the calculation of the ideal tidal volume of each patient will be performed, after which they will be positioned in the same way as baseline aspiration, in assisted-controlled pressure ventilation, increasing 10 cmH2O in inspiratory pressure and, in ventilatory mode. -controlled by volume, we will increase 50% of the tidal volume for a period of 10 minutes, observing the peak that cannot exceed 40 cmH2O in both ventilation modes, and then three aspirations will be performed for 15 seconds and with an interval of 30 seconds.

Sponsors & Collaborators

  • Instituto de Cardiologia do Rio Grande do Sul

    lead OTHER

Principal Investigators

  • Bruna Eibel, Dr · Instituto de Cardiologia

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
CROSSOVER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-07-01
Primary Completion
2021-01-30
Completion
2021-03-01

Countries

  • Brazil

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04583371 on ClinicalTrials.gov