Pulse Oximeter Hypoxia
NCT04562584 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 12
Last updated 2020-09-24
Summary
The aim of this project is to test the accuracy of pulse oximeters (devices intended to measure oxygen saturation in blood noninvasively) during mild, moderate and severe hypoxia (a lower-than-normal concentration of oxygen in arterial blood); ie, a range of arterial HbO2 saturations from 100 to down to 70%. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin (hemoglobin carrying oxygen) saturation, that is arterial blood sample processed in a laboratory.
Conditions
- Oximetry
Interventions
- DEVICE
-
MyHomeDoc
MyHomeDoc device SpO2 measurements and parallel blood gas analysis to determine oxyhemoglobin saturation (SaO2) using an ABL-90 multi-wavelength oximeter.
Sponsors & Collaborators
-
MyHomeDoc Ltd.
lead INDUSTRY
Principal Investigators
-
Philip E Bickler, Ph.D., M.D. · University of California, San Francisco
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-06-03
- Primary Completion
- 2020-06-04
- Completion
- 2020-06-04
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT06022523 ·Status: UNKNOWN ·Phase: NA
-
Induced Hypoxia Study for Validation of SpO2 Accuracy
NCT00788983 ·Status: COMPLETED
-
Pulse Oximeter Accuracy During Stable Hypoxia Plateaus
NCT06460246 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters in Profound Hypoxia
NCT05920278 ·Status: COMPLETED
-
Accuracy of ScanWatch Pulse Oximeter With Profound Hypoxia
NCT04380389 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters With Profound Hypoxia At Rest (NIHO17)
NCT05745662 ·Status: COMPLETED
-
SpO2 Comparison Between Commercial Smartwatch and Medical-grade Pulse Oximeter During Hypoxia
NCT05657288 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Noninvasive Pulse Oximeter Sensor (MightySat RX)
NCT03125135 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Evie Ring Pulse Oximeter in Profound Hypoxia
NCT06101654 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters With Profound Hypoxia at Rest
NCT04814823 ·Status: COMPLETED
-
Determination of SpO2 and PR Accuracy Specifications at Rest (71Ag_Vital-0031)
NCT05297500 ·Status: ACTIVE_NOT_RECRUITING
-
Accuracy of Detection of Methemoglobin With Pulse Oximetry
NCT03869840 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters With Profound Hypoxia At Rest (NIHO18)
NCT05807464 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters During Profound Hypoxia
NCT05790616 ·Status: UNKNOWN ·Phase: NA
-
Pulse Oximeter Test
NCT03569163 ·Status: COMPLETED
-
Accuracy of the EvieMED Ring Pulse Oximeter in Profound Hypoxia
NCT06459206 ·Status: RECRUITING
-
Accuracy of SpO2 for Noninvasive Pulse Oximeter Sensor (LNCS ADTX)
NCT03125018 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters With Profound Hypoxia At Rest (NIHO19)
NCT05807477 ·Status: COMPLETED
-
Alternate Methodology of Pulse Oximeter Validation
NCT03628560 ·Status: SUSPENDED ·Phase: NA
-
SpO2 Accuracy Low Saturation Validation of the OxySoftN Sensor
NCT04811963 ·Status: COMPLETED
-
Finger Pulse Oximeters in Hosptial Setting
NCT06994663 ·Status: COMPLETED
-
Hypoxia Blood Validation in Multiple Pulse Oximeters
NCT00881829 ·Status: UNKNOWN
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT04324385 ·Status: COMPLETED
-
Accuracy Of The Owlet OSS 3.0 During Standardized Stable Hypoxia Plateaus
NCT06850610 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters With Profound Hypoxia At Rest (NIHO16)
NCT05745675 ·Status: COMPLETED