Different Intra-abdominal Pressures and Optic Nerve Size
NCT04556877 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 78
Last updated 2020-09-21
Summary
In intensive care patients, high intraabdominal pressure is frequently encountered. Intra-abdominal pressure is often measured as high, especially after major abdominal surgery procedures. In recent years, various studies have reported that the increase in optic nerve diameter measured by ultrasound correlates with the level of intracranial pressure. Optic nerve diameter measurement with ultrasound is a non-invasive procedure. Intra-abdominal pressure measurements are also routinely performed in intensive care patients. In the measurement of abdominal pressure, the bladder catheter, which is already available in every patient who comes to intensive care, is used. In this study, the intra-abdominal pressure values present in the file of each patient undergoing major abdominal surgery who were taken to intensive care unit will be taken. Orbital USG will be performed on the 6th, 12th and 24th hours on admission to the intensive care unit to measure the diameter of the optic nerve, and the relationship between the intra-abdominal pressure value and optic nerve diameters will be investigated.
Conditions
- Major Surgery
- Intraabdominal Hypertension
- Optic Nerve Congestion
Interventions
- PROCEDURE
-
Intraabdominal pressure and optic nerve diameters
Measuring Intraabdominal pressure with a Foley cathater and measuring optic nerve diameters with a USG
Sponsors & Collaborators
-
Trakya University
lead OTHER
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-06-15
- Primary Completion
- 2020-06-15
- Completion
- 2020-06-15
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Optic Nerve Sheath Diameter in Urologic Surgery
NCT05846555 ·Status: UNKNOWN
-
Effect of Lithotomy Position on Optic Nerve Sheath Diameter
NCT06464419 ·Status: RECRUITING
-
Evaluation of Optic Nerve Sheath Diameter Changes During Cardiopulmonary Bypass in Open Heart Surgery
NCT07253922 ·Status: COMPLETED
-
This Study Performed to Develop a New Technique for Measuring the Intra Abdominal Pressure
NCT02319213 ·Status: COMPLETED ·Phase: NA
-
Optic Nerve Diameter and Intraocular Pressure Changes in Patients Undergoing Vitrectomy Under General Anesthesia
NCT05195801 ·Status: UNKNOWN
-
Optic Nerve Sheath Diameter and Postoperative Cognitive Disfunction at Laparoscopic Surgery
NCT07264764 ·Status: COMPLETED
-
Effect of Different Positive End-Expiratory Pressure (PEEP) Levels on Optic Nerve Sheath Diameter
NCT07085949 ·Status: COMPLETED
-
Intraocular Pressure and Optic Nerve Sheath Diameter Changes at Different PEEP Levels
NCT03938402 ·Status: TERMINATED ·Phase: NA
-
Optic Nerve Sheath Ultrasound During Electroconvulsive Therapy
NCT06607679 ·Status: COMPLETED
-
Effect of Tourniquet Application on Optic Nerve Sheath Diameter
NCT04758091 ·Status: COMPLETED
-
Different Resectoscopes Effects to Optic Nerve Sheath Diameter
NCT04765397 ·Status: COMPLETED ·Phase: NA
-
Intraocular Pressure, Optic Nerve Sheath Diameter and Optic Perfusion Pressure of Minimal Low and High-Flow Anesthesia
NCT06684704 ·Status: COMPLETED ·Phase: NA
-
Pneumoperitoneum and Cerebral Oxygenation
NCT04671121 ·Status: COMPLETED ·Phase: NA
-
NIRS and Anesthesiology
NCT05978310 ·Status: UNKNOWN
-
Anesthesia on Optic Nerve Sheath Diameter
NCT04407715 ·Status: COMPLETED ·Phase: NA
-
The Application of Ultrasonic Measurement of Optic Nerve Sheath Diameter in Liposuction Surgery
NCT06685952 ·Status: COMPLETED
-
Changes in Optic Nerve Sheath Diameter in Desflurane Based General Anesthesia During Laparoscopic Cholecystectomies
NCT06896604 ·Status: COMPLETED
-
Can Optic Nerve Sheath Diameter Measurement Predict Negative Neurological Outcome ?
NCT02637258 ·Status: UNKNOWN
-
Postoperative Complications in Patients With Obesity Hypoventilation Syndrome
NCT02980770 ·Status: UNKNOWN
-
Effect of Hot Pack Application on Gastrointestinal Motility After Abdominal Surgery
NCT06892782 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of Spinal Needle Type on Optic Nerve Sheath Diameter
NCT06497634 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of PEEP on Subdural Pressure, Optic Nerve Sheath Diameter, Lung Compliance and Brain Perfusion Pressure
NCT04316208 ·Status: UNKNOWN ·Phase: NA
-
the Effect of Different Mechanical Ventilation Modes on Optic Nerve Diameter and Conscious Functions
NCT04413903 ·Status: COMPLETED ·Phase: NA
-
General Anesthesia on Blood Pressure and Intraocular Pressure in Geriatric Patients Undergoing Cataract Surgery
NCT06482996 ·Status: RECRUITING
-
Evaluation of Cerebral Oxygenation During Orthopedic Surgeries Performed in the Beach Chair Position Under General Anesthesia
NCT07270341 ·Status: RECRUITING