Pulse CONtour and BIoimpedance for Measurements of Stroke Volume During Changes in CARdiac Preload
NCT04231656 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2021-04-21
Summary
Fluid therapy guided by stroke volume response to repeated fluid challenges is used for hemodynamic optimization during general anesthesia. Two types of devices that measure stroke volume non-invasively are primarily available for intermediate-risk surgery under general anesthesia. They are based on two different techniques, (1) pulse contour analysis, and (2) transthoracic bioimpedance. They have never been compared with each other. Therefore, it is not known (1) whether they are interchangeable for the measurement of stroke volume changes (usually assessed as the "concordance" of two techniques), and (2) whether one is better than the other.
The aim is to study the concordance of these two non-invasive hemodynamic devices. it will use both of them in patients undergoing intermediate risk surgery. They will be tested during modifications of cardiac preload induced by Trendelenburg and anti-Trendelenburg positioning, as well as during intraoperative fluid challenges, vasopressor boluses and alveolar recruitment maneuvers.
Conditions
- Hemodynamic, Monitoring
- Anesthesia
- Blood Pressure
Interventions
- DEVICE
-
CLEARSIGHT and NICCOMO measurements in sequence A
Starting from 0° position, shift to position +20°, then tilt to -20°, and finally back to the 0° position.
- DEVICE
-
CLEARSIGHT and NICCOMO measurements in sequence B
Starting from 0° position, shift to position -20°, then tilt to +20°, and finally back to the 0° position and collect the last group of figures.
Sponsors & Collaborators
-
University Hospital, Lille
lead OTHER
Principal Investigators
-
Benoit Tavernier, MD,PhD · University Hospital Lille, France
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-02-12
- Primary Completion
- 2020-05-07
- Completion
- 2020-05-07
Countries
- France
Study Locations
More Related Trials
-
Assessment of Stroke Volume in Shock Using Echocardiography Versus Bioreactive Impedance
NCT07020637 ·Status: RECRUITING
-
Evaluation of a Non-invasive Cardiac Output Monitoring System.
NCT03178162 ·Status: COMPLETED
-
Preload Dependency by Impedance Cardiography After Cardiac Surgery
NCT02132871 ·Status: COMPLETED
-
The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients
NCT04604886 ·Status: UNKNOWN ·Phase: NA
-
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
NCT05508711 ·Status: COMPLETED
-
Assessment of Plasma Lactate in Non-cardiac Surgery Monitoring by Transthoracic Echocardiography
NCT03103373 ·Status: UNKNOWN ·Phase: NA
-
Bio Impedance Electrical Analysis to Predict Outcome After Cardiac Surgery
NCT05229159 ·Status: COMPLETED
-
Comparison of Dynamic Fluid Responsiveness by EIT and Transpulmonary Thermodilution in Postoperative of CABG Patients
NCT04362033 ·Status: UNKNOWN ·Phase: NA
-
Transhepatic Echography for Fluid Responsiveness After Cardiovascular Surgery
NCT04914455 ·Status: COMPLETED
-
Ventricular Stimulation as Predictor of Hypovolemia After Cardiac Surgery
NCT03926910 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Ability of the esCCO and the Volume View to Measure Trends in Cardiac Output During Cardiac Surgery
NCT02964663 ·Status: COMPLETED
-
Automated Inferior Vena Cava Collapsibility Index Fluid Responsiveness in Ventilated Patients After Cardiac Surgery.
NCT05283590 ·Status: UNKNOWN
-
Echocardiographic Findings and 30-days Outcomes for Intraventricular Conduction Delay in Patients Undergoing Elective Surgeries
NCT02718313 ·Status: COMPLETED
-
Validation of Uncalibrated Cardiac Output Measurement With LiDCOrapid in the Resuscitation of Critically Ill Patients With Septic Shock: A Prospective Cross-sectional Study.
NCT04705493 ·Status: COMPLETED
-
Uncalibrated Pulse Contour to Assess Fluid Responsiveness in Off Pump Cardiac Surgery
NCT06822361 ·Status: COMPLETED
-
Evaluation of a Non-invasive Cardiac Output Monitoring System.
NCT03178097 ·Status: COMPLETED
-
Comparative Noninvasive Continuous Cardiac Output by the Clearsight With Invasive Monitoring by Pulsioflex in Abdominal Surgery
NCT02717468 ·Status: COMPLETED ·Phase: NA
-
3D & Speckle Tracking Together as a Marker for Early Outcome in Cardiac Surgery
NCT02642770 ·Status: COMPLETED
-
C-MAC Videolaryngoscope for Insertion of a Transesophageal Echocardiography Probe in ICU Patients
NCT04980976 ·Status: COMPLETED ·Phase: NA
-
Internal Jugular Venous Distensibility Index and Innominate Venous Flow Patterns As Predictors of Fluid Responsiveness
NCT05930600 ·Status: COMPLETED
-
Non-Invasive Cardiac Output Measurement for CRT Optimization
NCT02126241 ·Status: COMPLETED ·Phase: NA
-
The Role of Left Ventricular Outflow Tract (LVOT) Velocity-time Integral (VTI) and Respiratory Variability at Peak Rate (Vpeak) in Predicting Hypotension After General Anesthesia Induction
NCT07121699 ·Status: NOT_YET_RECRUITING
-
Sensor-equipped Ultrathin Pressure Microcatheter Versus Pressure Wire for Physiological Measurements
NCT05417763 ·Status: COMPLETED
-
Evaluation of Monitoring TECHNOlogies in the PERI-OPerative Care of Cardiac Surgical Patients
NCT02658006 ·Status: COMPLETED
-
Cardiac Output Monitoring by Transpulmonary Thermodilution and Transthoracic Echocardiography in Critically Ill Patients
NCT04637126 ·Status: COMPLETED