Evaluation of a Semiconductor Camera for the DaTSCAN™ Exam

NCT03980418 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 96

Last updated 2022-08-24

No results posted yet for this study

Summary

The semiconductor (cadmium-zinc-telluride, CZT) cameras significantly increase detection sensitivity in Single Photon Emission Computer Tomoscintigraphy (SPECT)(1) . The clinical routine applications of these cameras are today mainly limited to myocardial tomoscintigraphy with CZT dedicated cameras. Several studies whose one was done in Hospital of Nancy, made it possible to demonstrate a good diagnosis agreement between conventional cameras and semiconductor cameras in this indication, with better image quality obtained with semiconductor cameras (2). Today, so-called "wide field" semiconductor cameras are available in the clinic and allow for any type of SPECT examination. A comparative study between conventional and semiconductor cameras has been conducted for bone scintigraphy, and shows diagnostic superiority with this new type of camera (3).

In addition, the new VERITON-CT ™ (Spectrum Dynamics Medical) camera has 12 mobile CZT-based detectors positioned around the patient allowing tomographic acquisitions and focusing the acquisition on the organ studied. This camera has a sensitivity of detection higher than that of conventional cameras and thus reduces the activity injected into the patient and / or the recording time.

To date, no study has compared the two types of cameras in nuclear neurology and in particular, for the SPECT DaTSCAN ™ imaging of the pre-synaptic dopaminergic pathway.

DaTSCAN ™ exam is used in clinical routine:

1. for the diagnosis of Parkinson's disease or related diseases when in doubt with an essential tremor (4) or
2. if suspicion of Lewy body disease, if in doubt with Alzheimer's disease (5). If the interpretation of DaTSCAN ™ exam is first visual, the quantification may increase accuracy diagnosis (6). Also, the database creation specific to each type of camera is recommended(7).

The purpose of this study is to compare the diagnostically relevant informations and the quantitative analysis provided by the DaTSCAN™ SPECT, recorded on the conventional camera and recorded on the semiconductor camera VERITON-CT™

Conditions

  • Parkinson Disease

Interventions

PROCEDURE

DaTSCAN SPECT/CT in VERITON-CT camera

the intervention is based on two recordings in camera VERITON-CT ; the first, in focus striatum mode and the second in brain focus mode

Sponsors & Collaborators

  • Central Hospital, Nancy, France

    lead OTHER

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-09-05
Primary Completion
2020-09-03
Completion
2020-09-03

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03980418 on ClinicalTrials.gov