Fixation and Stability of the Trident® II Clusterhole HA Shells
NCT03724058 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 87
Last updated 2025-09-04
Summary
The purpose of the Trident® II project is to introduce a cup system that modernizes and streamlines Stryker's acetabular shell portfolio. The Trident® II Clusterhole HA Shell combines the history of Stryker's Trident® shells with plasma spray CpTi with HA coating. Plasma spray coating and HA is considered to be the gold standard in orthopaedics today. This coating will help the cup to achieve early stability and long term fixation.
One of the causes for implant failure is loosening and osteolysis. Osteolysis can be triggered when metal or polyethylene wear particles from the implant or bearing surfaces migrate between implant and surrounding host bone tissue. With the development of sequential irradiated and annealed highly crosslinked polyethylene (X3) wear rates (mean proximal, 2-dimensional and 3-dimensional) have been substantially reduced to 0.001 mm/y, calculated between 1 year and 5 years.
The Trident® II Clusterhole HA shells have a plasma sprayed CpTi coating compared to the arc-deposition CpTi coating on legacy Trident® shells, both designed to allow bone ongrowth. With this study the investigators want to prove equivalent implant fixation of both type of cups.
The primary objective is the assessment of prosthetic fixation and migration results after two years of the Trident® II Clusterhole HA shell compared to the legacy Trident® Hemi HA shell by means of RSA. It is hypothesized that they will perform equally.
The secondary outcome measure will be long-term (10-year) survival based on the two-year migration patterns combined with clinical factors and radiographic aspects. In order to identify other clinical parameters besides the fixation of the prosthesis components, clinical scores and radiographic aspects will be correlated with the RSA outcome. The 10-year results will be used to verify the predicted long-term survival results.
Conditions
- Hip Replacement Arthroplasty
Interventions
- DEVICE
-
Trident® II Clusterhole HA Acetabular Shell
Hip arthroplasty
- DEVICE
-
Trident® Hemispherical Acetabular Shell
Hip arthroplasty
Sponsors & Collaborators
-
Region Skane
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-02-06
- Primary Completion
- 2023-06-05
- Completion
- 2031-05-11
Countries
- Sweden
Study Locations
More Related Trials
-
Comparison of Two Hydroxy-apatite Coated Hip Stems
NCT03577522 ·Status: COMPLETED ·Phase: NA
-
Importance of Hollow or Solid Centralizer for Polished, Collarless and Tapered Stems in Total Hip Arthroplasty
NCT01918540 ·Status: COMPLETED ·Phase: NA
-
Bone Remodeling Around HA-coated Acetabular Cups.
NCT00159497 ·Status: COMPLETED ·Phase: PHASE4
-
Knotless Implants As an Alternative for Capsular Closure in Primary Hip Arthroscopy: a Prospective, Multi-Center Study
NCT06500364 ·Status: RECRUITING ·Phase: PHASE4
-
Study Comparing BoneMaster Hydroxyapatite Coating With Plasma-sprayed Hydroxyapatite Coating on Acetabular Cups
NCT00859976 ·Status: COMPLETED ·Phase: NA
-
Hydroxyapatite (HA) Coating Versus Plasma Porous Spray (PPS) in Press-fit Acetabular Components Early Outcomes With DEXA
NCT02447653 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a New Coating in Cement Less Femoral Stems
NCT02321683 ·Status: COMPLETED ·Phase: PHASE4
-
Analysis of a Tapered Porous Coated Stem and a Cementless Hemispherical Acetabular Component
NCT03168750 ·Status: COMPLETED
-
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
NCT05773261 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Bone Remodeling Around a Trabecular Titanium Cup in Total Hip Arthroplasty
NCT06287021 ·Status: RECRUITING ·Phase: NA
-
Impact of Component Design and Fixation in Total Knee Arthroplasty
NCT03272178 ·Status: COMPLETED
-
Clinical Observation Study of the Hydroxylapatite-coated SLPLUS™MIA Hip Shaft
NCT04036071 ·Status: TERMINATED
-
Real-Time Instrument for Acetabular Shell Positioning
NCT02006251 ·Status: TERMINATED
-
Project JAY HAP Registration Study
NCT02347397 ·Status: COMPLETED ·Phase: NA
-
Medium Term Survivorship of Cementless THA Performed Using the Bone Preservation Tri-Lock Femoral Stem
NCT01566916 ·Status: UNKNOWN ·Phase: NA
-
Observational Study Evaluating Outcomes of Hip Arthroplasty Using Tornier Dual Mobility Acetabular Cup
NCT02062450 ·Status: COMPLETED
-
Intraoperative Case Series Study: Trial Rasp Position Versus SL-PLUS™ MIA Ti/HA Femoral Hip Stem Position
NCT02664272 ·Status: COMPLETED
-
A Comparison of Two Type of Stems in Revision Hip Arthroplasty
NCT00253838 ·Status: COMPLETED ·Phase: NA
-
A Multi-centre, Prospective Surveillance to Assess Mid-term Performance of the Mpact Cup
NCT02196818 ·Status: TERMINATED
-
RCT Comparing the DEXA Results of the HA-Omnifit Versus the Symax Uncemented Hip Stem
NCT01695213 ·Status: COMPLETED ·Phase: PHASE4
-
The 10-year Follow-up of the Delta-TT Trial.
NCT06864897 ·Status: RECRUITING
-
Comparing Collared and Collarless Femoral Stems in Primary Total Hip Arthroplasty
NCT07337642 ·Status: RECRUITING ·Phase: NA
-
Anatomical Femoral Stem in Total Hip Arthroplasty
NCT04243980 ·Status: UNKNOWN
-
Cemented TrendHip® - Multicenter PMCF Study on Total Indications
NCT04943328 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Primary Uncemented Partly Ti-coated Total Hip Prosthesis With and Without HA, and Alumina-on-alumina Articulation
NCT01118247 ·Status: UNKNOWN ·Phase: NA