Fixation and Stability of the Trident® II Clusterhole HA Shells

NCT03724058 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 87

Last updated 2025-09-04

No results posted yet for this study

Summary

The purpose of the Trident® II project is to introduce a cup system that modernizes and streamlines Stryker's acetabular shell portfolio. The Trident® II Clusterhole HA Shell combines the history of Stryker's Trident® shells with plasma spray CpTi with HA coating. Plasma spray coating and HA is considered to be the gold standard in orthopaedics today. This coating will help the cup to achieve early stability and long term fixation.

One of the causes for implant failure is loosening and osteolysis. Osteolysis can be triggered when metal or polyethylene wear particles from the implant or bearing surfaces migrate between implant and surrounding host bone tissue. With the development of sequential irradiated and annealed highly crosslinked polyethylene (X3) wear rates (mean proximal, 2-dimensional and 3-dimensional) have been substantially reduced to 0.001 mm/y, calculated between 1 year and 5 years.

The Trident® II Clusterhole HA shells have a plasma sprayed CpTi coating compared to the arc-deposition CpTi coating on legacy Trident® shells, both designed to allow bone ongrowth. With this study the investigators want to prove equivalent implant fixation of both type of cups.

The primary objective is the assessment of prosthetic fixation and migration results after two years of the Trident® II Clusterhole HA shell compared to the legacy Trident® Hemi HA shell by means of RSA. It is hypothesized that they will perform equally.

The secondary outcome measure will be long-term (10-year) survival based on the two-year migration patterns combined with clinical factors and radiographic aspects. In order to identify other clinical parameters besides the fixation of the prosthesis components, clinical scores and radiographic aspects will be correlated with the RSA outcome. The 10-year results will be used to verify the predicted long-term survival results.

Conditions

  • Hip Replacement Arthroplasty

Interventions

DEVICE

Trident® II Clusterhole HA Acetabular Shell

Hip arthroplasty

DEVICE

Trident® Hemispherical Acetabular Shell

Hip arthroplasty

Sponsors & Collaborators

  • Region Skane

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
40 Years
Max Age
75 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-02-06
Primary Completion
2023-06-05
Completion
2031-05-11

Countries

  • Sweden