RSA Study Using Two Types of Uncemented Acetabular Components and the Uncemented HA Coated Symax Stem
NCT01618084 · Status: UNKNOWN · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2012-06-13
Summary
The Trident Tritanium acetabular component of a total hip prosthesis is a new developed uncemented acetabular component. In this randomized controlled trial (RCT) the tritanium cup will be compared with the Trident HA acetabular component in two equal sized groups. The Symax HA coated stem will be used as femoral component in both groups.
Study Objectives:
* The primary objective is to determine the prosthetic migration of the uncemented acetabular and femoral total hip components using model based RSA technique
* Secondary objectives are on one hand to assess clinical outcome on the other hand assessing patient satisfaction in both groups using Harris Hip Score, Oxford Hip Score, WOMAC, and EQ-5D questionnaires
* Tertiary objective is to assess bone remodeling of the uncemented acetabular components and the HA-coated Symax hip stem using QCT derived from usinf F18-fluoride PET in a cohort of 12 consecutive patients of this RCT
A total of 50 patients will be enrolled in this RCT divided into two equal groups. Patients have to fulfill the inclusion and exclusion criteria.
All evaluations will be done pre-operatively with 2 weeks before surgery, and after surgery at 4 weeks, 3 and 6 months and 1 and 2 years.
Conditions
Interventions
- DEVICE
-
Tritanium acetabular component
Total hip arthroplasty using a tritanium uncemented acetabular component
Sponsors & Collaborators
-
Stryker Orthopaedics
collaborator INDUSTRY -
Maastricht University Medical Center
lead OTHER
Principal Investigators
-
Lodewijk Van Rhijn, professor · Maastricht University Medical centre
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 35 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-11-30
- Primary Completion
- 2014-11-30
- Completion
- 2014-12-31
Countries
- Netherlands
Study Locations
More Related Trials
-
A Two Centre Study to Assess the Stability and Long-term Performance of the C-Stem™ AMT in a Total Primary Hip Replacement
NCT00872573 ·Status: TERMINATED ·Phase: PHASE4
-
A Randomized RSA Study Comparing HXLPE to Conventional Polyethylene in Cemented Total Hip Arthroplasty
NCT04322799 ·Status: COMPLETED ·Phase: NA
-
The Metaphyseal Hip Prosthesis - Total Hip
NCT01501955 ·Status: COMPLETED ·Phase: NA
-
Hip Arthroplasty With SL Cementless
NCT04979104 ·Status: COMPLETED
-
Importance of Restoring Biomechanical Correct Hip Anatomy During Total Hip Arthroplasty
NCT01512550 ·Status: COMPLETED ·Phase: NA
-
Randomized Controlled RSA Study Comparing the Taperloc Complete Versus the Taperloc Complete Microplasty.
NCT03409666 ·Status: COMPLETED ·Phase: NA
-
Importance of Hollow or Solid Centralizer for Polished, Collarless and Tapered Stems in Total Hip Arthroplasty
NCT01918540 ·Status: COMPLETED ·Phase: NA
-
Cemented TrendHip® - Multicenter PMCF Study on Total Indications
NCT04943328 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Polymethyl Methacrylate and (PEGT/PBT) Centralizer by the Uncemented BIHAPRO THP
NCT00214760 ·Status: TERMINATED ·Phase: PHASE3
-
Evaluation of a New Coating in Cement Less Femoral Stems
NCT02321683 ·Status: COMPLETED ·Phase: PHASE4
-
SmartSet HV and Palacos R RSA Bone Cements in Primary Total Hip Arthroplasty
NCT00837850 ·Status: COMPLETED ·Phase: NA
-
AMIStem-H Radiographic Analysis
NCT02829866 ·Status: COMPLETED
-
Analysis of a Tapered Porous Coated Stem and a Cementless Hemispherical Acetabular Component
NCT03168750 ·Status: COMPLETED
-
Evaluation of the Wear of Vitamin E Treated Polyethylene Components in Primary THA Using RSA
NCT00551967 ·Status: UNKNOWN ·Phase: NA
-
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
NCT05773261 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Exception Cementless Hip Stem
NCT04349046 ·Status: ACTIVE_NOT_RECRUITING
-
Evaluation of Stability of Two Uncemented Hip Implants Used for Total Hip Arthroplasty
NCT02656771 ·Status: UNKNOWN ·Phase: NA
-
Hydroxyapatite (HA) Coating Versus Plasma Porous Spray (PPS) in Press-fit Acetabular Components Early Outcomes With DEXA
NCT02447653 ·Status: COMPLETED ·Phase: NA
-
Long-term Outcomes of Conical Tapered Stems in Cementless Total Hip Arthroplasty Due to Congenital Hip Pathologies
NCT04748458 ·Status: COMPLETED
-
RSA - ACTIS Hip Stem
NCT04879732 ·Status: COMPLETED ·Phase: NA
-
Study Comparing BoneMaster Hydroxyapatite Coating With Plasma-sprayed Hydroxyapatite Coating on Acetabular Cups
NCT00859976 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Cementing Techniques of the Femoral Component in a Hip Prosthesis
NCT01952067 ·Status: COMPLETED ·Phase: NA
-
Trilogy AB Acetabular Hip System Post Approval Study
NCT00715026 ·Status: TERMINATED ·Phase: PHASE4
-
A Register Based Prospective Study During Implementation of a New Cup
NCT04350255 ·Status: RECRUITING ·Phase: NA
-
Stability of Revision Total Hip Arthroplasty Implants Using Radiostereometric Analysis
NCT01668160 ·Status: WITHDRAWN ·Phase: NA