High Versus Low Positive End Expiratory Pressure With Alveolar Recruitment Maneuver in Laparoscopic Bariatric Surgeries

NCT03505632 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60

Last updated 2019-04-08

No results posted yet for this study

Summary

For the patients undergoing laparoscopic bariatric surgery, application of low (PEEP) with frequent alveolar recruitment maneuver could be beneficial and superior to conventional ventilation with a high (PEEP) in improving lung compliance, better oxygenation and less dead space .This hypothesis could be achieved by minimizing the expected lung atelectasis during anesthesia for this particular kind of laparoscopic surgery without any haemodynamics alterations.This trial was designed to study the effects of alveolar recruitment strategy with low PEEP versus conventional mechanical ventilation with higher PEEP on the patients undergoing laparoscopic bariatric surgeries. The primary end point of the study will be the achievement of the highest dynamic lung compliance (Cdyn). Improvement of intraoperative oxygenation (Pao2/Fio2) and achievement of a lower dead space ratio (vd/vt), with stable intraoperative haemodynamics will be considered as secondary outcome

Conditions

  • Anesthesia

Interventions

DEVICE

Recruitment with low PEEP

Volume controlled ventilation with TV 6-8 ml/PBW . RR adjusted to keep the EtCO2 35-40 mmHg. I/E ratio1:2 and FiO2 0.40.Patients will receive PEEP of 5cmH2O. RM will be done by increasing the PEEP in stepwise manner. First PEEP increase to 10 cmH2O (3 breaths),then to 15 cm H2O (3 breaths) and finally PEEP raise to 20 cmH2O (10 breaths).Then PEEP decrease by 5 cmH2O increments every (3 breaths) until back to PEEP 5 cmH2O. RM will take 2 minutes. RM will be carried out at the following times: post intubation(T1) , after peritoneal insuflation(T2) ,after desuflation (T3) and before extubation(T4) . The peak airway pressure should not exceed 40 cmH2O. Monitoring of the following parameters :Dynamic lung compliance ,Horowitz index ,dead space and driving pressure .

DEVICE

High PEEP without RM

Volume controlled ventilation will carried out with tidal volume 6-8 ml/kg for predicted body weight. The PBW calculated according to the formula : 50 + 0.91 × {height (cm)-152.4} for men and 45.5 + 0.91 × {height (cm) - 152.4} for women. The respiratory rate adjusted to keep the EtCO2= 35-40 mmHg. The inspiratory to expiratory ratio (I:E ratio) 1:2 and FiO2 0.40.Patients will receive high PEEP of 15cmH2O from the start and continue all through the procedure . Monitoring of dynamic lung compliance,Horowitz index,dead space and driving pressure will be carried out at the following times: post intubation(T1) , after peritoneal insuflation(T2) ,after desuflation (T3) and before extubation(T4) . The peak airway pressure should not exceed 40cmH2O.

Sponsors & Collaborators

  • Mansoura University

    lead OTHER

Principal Investigators

  • Amgad A Zaghloul, MD · Mansoura University

  • Ahmed M Farid, MD · Mansoura University

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
20 Years
Max Age
60 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2017-06-01
Primary Completion
2019-03-01
Completion
2019-03-31

Countries

  • Egypt

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.