Response to Varying the Rate of Administration of a Fluid Challenge
NCT03300323 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2017-10-03
Summary
Administration of intravenous fluids is a key step in the management of the post-operative patient. Fluid management has been identified as one area that can affect rates of post-operative complications and outcomes. It is important to give the right amount of fluid, enough to optimise cardiovascular function, but not so much that we flood the cells. To guide this, we use a fluid challenge, administration of a small amount of fluid to test the cardiovascular response. At present there is significant inter-user variability in the method of administration of a fluid challenge. To ensure accuracy and reliability in assessing the response to a fluid challenge, the optimal method of administration needs to be determined.
The aim of this study is to investigate the optimal rate to give a fluid challenge over. Patients will be randomised to receive a fluid challenge over either 5 or 20 minutes. Both of these rates are within the currently accepted range. All patients will receive a dose of 4ml/kg of intravenous fluid. Previous work has shown this to be the optimal dose to reliably stress the system.
Measurement of the mean pressure in the cardiovascular system (mean systemic filling pressure or Pmsf) during the administration of a fluid challenge will be used to assess which rate of administration effectively challenges the cardiovascular system. Pmsf is measured using a pneumatic tourniquet inflated for sixty seconds, above an arterial line. The invasive arterial pressure is observed to then determine Pmsf. Cardiac output will also be monitored during and after administration of the fluid challenge. Since the microcirculation may remain impaired despite stabilisation of the macrocirculation, we will also observe this at baseline, on completion of the fluid challenge, and at 5 minute intervals for 15 minutes. This is observed using a handheld camera placed under the tongue.
The hypothesis is that administration of a fluid challenge at a faster rate, over 5 minutes as opposed to 20 minutes, will be a more effective test of the cardiovascular response. An effective fluid challenge is defined as one that causes a significant rise in mean systemic filling pressure. As such, a higher proportion of responders will be seen in response to the faster rate of fluid challenge. A responder is defined by an increase in cardiac output or stroke volume of more than 10% from baseline in response to a fluid challenge.
Conditions
- Peri-operative Fluid Management
Interventions
- DIAGNOSTIC_TEST
-
IV fluid challenge administration
Administration of an intravenous fluid challenge to assess for fluid responsiveness
Sponsors & Collaborators
-
St George's Healthcare NHS Trust
lead OTHER
Principal Investigators
-
Maurizio Cecconi · St George's University Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-10-31
- Primary Completion
- 2018-02-28
- Completion
- 2018-02-28
More Related Trials
-
Clinical Trial of Standard Versus Goal-Directed Perioperative Fluid Management (GDT) for Patients Undergoing Liver Resection
NCT01596283 ·Status: COMPLETED ·Phase: PHASE3
-
Impact of Early Goal-directed Fluid Therapy in Hypovolemic Patients Undergoing Emergency Surgery
NCT01653977 ·Status: TERMINATED ·Phase: NA
-
Passive Leg Raise and Mini-fluid Challenge Effect on Various Cardiac Output Surrogates for Fluid Responsiveness
NCT06390423 ·Status: RECRUITING
-
Fluid Management in Patients Undergoing Cardiac Surgery
NCT02895659 ·Status: COMPLETED ·Phase: PHASE4
-
Hemodynamic Optimization By Non-Invasive Determination Of Cardiac Output In Critically Ill Patients
NCT01309724 ·Status: COMPLETED ·Phase: NA
-
Perioperative Fluid Management: Goal-directed Versus Restrictive Strategy
NCT02625701 ·Status: COMPLETED ·Phase: PHASE3
-
Comparison of 250 ml Versus 500 ml of Fluid Challenge
NCT03874923 ·Status: COMPLETED ·Phase: NA
-
The Validity of Peripheral Perfusion Index to Predict Fluid Responsiveness
NCT03805321 ·Status: COMPLETED
-
Small Volume Fluid Challenge as a Predictor of Fluid Responsiveness in Patients With Circulatory Failure
NCT03622099 ·Status: COMPLETED
-
Fluids and Catheters Treatment Trial (FACTT) - ARDS Clinical Research Network
NCT00281268 ·Status: COMPLETED ·Phase: PHASE3
-
Mini Fluid chAlleNge and End-expiratory Occlusion Test and to Assess flUid responsiVEness in opeRating Room
NCT03808753 ·Status: COMPLETED ·Phase: NA
-
"Mini Fluid Challenge Assessment: a Comparison Among Three Hemodynamic Tools"
NCT04934943 ·Status: NOT_YET_RECRUITING
-
Cardiac Responsiveness Assessment by CO2
NCT05430880 ·Status: UNKNOWN
-
Closed-Loop Fluid Administration System Using Hemodynamic Monitors
NCT02020863 ·Status: COMPLETED ·Phase: NA
-
Oral Fluid Volume Expansion
NCT01360333 ·Status: COMPLETED ·Phase: NA
-
Emergency Department (ED) Flow-directed Fluid Optimization Resuscitation Trial (EFFORT)
NCT01128413 ·Status: TERMINATED ·Phase: NA
-
Physiological Effects of 38°C vs. 22°C Fluid Therapy in Critically Ill Patients
NCT04576806 ·Status: WITHDRAWN ·Phase: NA
-
Use of a Mini-fluid Bolus to Identify Fluid Responsiveness
NCT03058653 ·Status: WITHDRAWN ·Phase: NA
-
Effect of Fluid Challenge on Glycocalyx
NCT03891342 ·Status: COMPLETED ·Phase: NA
-
Fluid Management in the Post Anesthesia Care Unit
NCT03799250 ·Status: UNKNOWN ·Phase: PHASE4
-
Fluid Management in the Post-Anesthetic Care Unit (PACU) at Sourasky Medical Center
NCT00995228 ·Status: UNKNOWN
-
Closed-loop Fluid Administration System: Pilot Study to Evaluate Feasibility
NCT01882075 ·Status: TERMINATED ·Phase: PHASE4
-
The Use of LiDCOplus in Fluid Resuscitation Decision-Making
NCT03349749 ·Status: COMPLETED
-
Perioperative Fluid Management in Patients Receiving Major Abdominal Surgery - Effects of Normal Saline Versus an Acetate Buffered Balanced Infusion Solution on the Necessity of Catecholamines for Cardiocirculatory Support
NCT02414555 ·Status: TERMINATED ·Phase: PHASE4
-
Time Course Evolution of Cardiac Output
NCT03694717 ·Status: COMPLETED