The Use of LiDCOplus in Fluid Resuscitation Decision-Making
NCT03349749 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 45
Last updated 2017-11-22
Summary
Unwell patients in the intensive care unit (ICU) often need supplementary fluids to be given into the bloodstream through a drip in a vein (venous cannula), however too much fluid can be harmful. It can sometimes be difficult to tell whether or not a patient will benefit from extra fluids so they are given a "fluid challenge", whereby a small volume of fluid is given quickly into the cannula and the change in their status is noted. If the patient's condition improves, this suggests that the patient is "fluid responsive" and needs more fluid.
A LiDCOplus haemodynamic monitor is a device used in the ICU to estimate the amount of blood ejected from the heart on each heartbeat using pressure readings obtained from a tube placed in one of the patient's arteries (arterial line).
The investigators aim to determine whether or not the use of this device called makes a difference to the judgement of "fluid responsiveness" when the patient is given a fluid challenge when compared to simply using measurements of pulse and blood pressure and assessing the circulation in the patient's limbs. This will allow the investigators to determine whether or not the LiDCOplus alters the decisions made by doctors and nurses about how much fluid to give their patients and hence if it is of any benefit.
Conditions
- Shock
Interventions
- DEVICE
-
LiDCOplus haemodynamic monitor
Patients in study group receive intravenous fluid bolus as part of standard fluid resuscitation. Fluid responsiveness (i.e. improvement in cardiac output) is estimated using both standard clinical parameters and by LiDCOplus haemodynamic monitor (with the clinician initially blinded to the latter) before a final decision about fluid responsiveness is made.
Sponsors & Collaborators
-
NHS Greater Glasgow and Clyde
lead OTHER
Principal Investigators
-
James A Patterson, MBChB · NHS Greater Glasgow and Clyde
Eligibility
- Min Age
- 16 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-03-22
- Primary Completion
- 2017-10-31
- Completion
- 2017-10-31
- FDA Device
- Yes
Countries
- United Kingdom
Study Locations
More Related Trials
-
Validation of the Fluid Responsiveness Index in Critically Ill Patients
NCT00894309 ·Status: UNKNOWN
-
Timing and Dose of Fluid Deresuscitation in Critically Ill Patients
NCT07275658 ·Status: RECRUITING
-
Effect of Fluid Resuscitation and Microcirculation
NCT01369524 ·Status: COMPLETED
-
Cardiac Responsiveness Assessment by CO2
NCT05430880 ·Status: UNKNOWN
-
Fluid Challenges in Intensive Care
NCT01787071 ·Status: COMPLETED
-
Fluid Responsiveness Evaluation in Sepsis-associated Hypotension
NCT02837731 ·Status: COMPLETED ·Phase: NA
-
Fluid Responsiveness Prediction During Prone Position
NCT05898269 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Point-of-Care Measurement With the RapidPoint 500 Blood Gas Analyser
NCT02449226 ·Status: COMPLETED
-
Response of Pulse Pressure Variation in PA Catheter Tracing to IV Fluid Bolus in the ICU
NCT02419404 ·Status: COMPLETED
-
Fluid Balance in the ICU - Interventions to Minimize Fluids in Patients With Septic Shock
NCT02473718 ·Status: COMPLETED ·Phase: NA
-
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous SO2 Variations to Define Fluid Responsiveness
NCT01941472 ·Status: COMPLETED ·Phase: NA
-
Fluid Management Surgical Patients in Intensive Care Unit.
NCT03455296 ·Status: COMPLETED ·Phase: NA
-
Restrictive Intravenous Fluids Trial in Sepsis
NCT03137446 ·Status: COMPLETED ·Phase: NA
-
PPV to Guide Fluid Management in the PICU
NCT02308371 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Accuracy of the Central Venous Pressure (CVP) Variation to Predict Fluid Responsiveness in Spontaneously Breathing Patients
NCT03780660 ·Status: COMPLETED
-
Comparison of Non-Invasive Methods of Assessing Fluid Responsiveness in ED and ICU Patients
NCT02679625 ·Status: COMPLETED
-
A Prospective Observational Study of the Expectations and Physiological Effects of Fluid Bolus Therapy
NCT03178578 ·Status: UNKNOWN
-
Impact of an Assisted Fluid Management System on Microvascular Parameters
NCT03965702 ·Status: COMPLETED ·Phase: NA
-
Patient Controlled Fluid Administration
NCT03176043 ·Status: UNKNOWN ·Phase: EARLY_PHASE1
-
Comparing Fluid Responsiveness Assessment Methods in Patients With Impaired Consciousness
NCT06180902 ·Status: RECRUITING ·Phase: NA
-
An Upgrading of the Resuscitative Patterns by Utilization of the Balanced Crystalloids and Synthetic Colloids and the Non-Invasive Hemodynamic Monitoring During Burn Shock
NCT00914563 ·Status: UNKNOWN ·Phase: PHASE2
-
Non-invasive Goal-directed thErapy oN cIrcUlatory Shock
NCT05336357 ·Status: RECRUITING ·Phase: NA
-
End-expiratory Occlusion Test and Lung Recruitment Maneuver to Assess Fluid responsiVeness In Surgical Patients
NCT03820440 ·Status: UNKNOWN ·Phase: NA
-
Evaluating Fluid Responsiveness in ICU Patients Using VTI and Trendelenburg Positioning
NCT06418022 ·Status: RECRUITING ·Phase: NA
-
Comparison of 250 ml Versus 500 ml of Fluid Challenge
NCT03874923 ·Status: COMPLETED ·Phase: NA