Correlation Between the SPhENo-Cardiograph™, a Seismocardiograph Device, and GE Vivid Q, an Echocardiograph, for Known Systemic Timing Intervals (STI)
NCT02636023 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 34
Last updated 2016-02-11
Summary
The study Sponsor, Heart Force Medical Inc. (HFM), has developed a patented medical device called the SPhENo-CardiographTM. The SPhENo-Cardiograph™ provides a non-invasive assessment of the electro-mechanical function of the heart. The electrocardiograph (ECG) represents the waveform of the electrical stimulus to the cardiac muscle. The mechanical actions of the electrical potentials delivered in the ECG are revealed as the seismocardiograph (SCG). The SCG represents the changes in acceleration of the heart during the cardiac cycle. The SCG waveform reflects the ultra-low frequency vibrations of cardiac contraction. These low frequency vibrations are transmitted through the sternum. Using the point of initiation of ventricular contraction on the ECG, the Q wave, with fiduciary points on the synchronous seismocardiograph, it is possible to determine timing events of the cardiac cycle. The timing events of the cardiac cycle during systole are referred to as Systolic Timing Intervals (STI) and comprise the Pre-Ejection Period (PEP) and the Left Ventricular Ejection Time (LVET). The PEP is the time from the Q wave to the Aortic valve opening. The Left Ventricular Eject Time (LVET) is the time between the Aortic Valve opening and closing. The ratio of PEP/LVET in individuals with established heart disease is \> 0.42. It is based on the formula described by Dr Arnold Weissler and first published in Circulation in 1968 (Weissler et al,1968). Weissler et al showed that the PEP/LVET ratio \>0.42 are indicative of a lengthening of the PEP with some marginal shortening of the LVET. This is indicative of pathology associated with the coronary circulation (Ahmed et al, 1972;). This ratio can then be used as part of a non-invasive quantitative assessment of cardiac performance (Lewis et al 1977).
Using the SPhENo-CardiographTM, HFM has developed an algorithm to assess heart health that otherwise requires a number of technologies; stethoscope, ECG and Carotid pulse tracing to identify the dicrotic notch or Aortic Valve closure.
Conditions
- Cardiovascular Risk Factor
Interventions
- DEVICE
-
SPhENo-Cardiograph
SPhENo-Cardiograph
Sponsors & Collaborators
-
Heart Force Medical Inc.
lead INDUSTRY
Principal Investigators
-
Karrin Fairman Young, ND · Boucher Institute of Naturopathic Medicine
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2015-08-31
- Primary Completion
- 2015-08-31
- Completion
- 2015-08-31
Countries
- Canada
Study Locations
More Related Trials
-
MultiPoint Pacing Programming Guided by Noninvasive Hemodynamics
NCT02064751 ·Status: COMPLETED ·Phase: NA
-
Further Study of AFGen1 Clinical Performance
NCT06335498 ·Status: COMPLETED
-
Correlation Research Study: IQ2, NcIQ and IQ101
NCT00491777 ·Status: COMPLETED ·Phase: PHASE1
-
Acute Optimization of Cardiac Resynchronization Therapy (CRT)Using Echocardiography and SonR
NCT01293526 ·Status: WITHDRAWN ·Phase: NA
-
Ultra-High Frequency - Electrocardiogram (UHF-ECG) for the Diagnosis of Ventricular Electrical Dyssynchrony (VED)
NCT06641362 ·Status: RECRUITING
-
Dynamic Data-Driven Management of Atrial Fibrillation Using Implantable Cardiac Monitors: The MONITOR-AF Study
NCT06352060 ·Status: COMPLETED
-
Monitoring of Arrhythmias and HRV in Patients With Heart Failure Treated With the CRT Pacemaker Renewal TR2
NCT00180531 ·Status: COMPLETED ·Phase: PHASE4
-
TRIAGE-CRT Telemonitoring in Patients With CHF and Indication of CRT-D
NCT00395642 ·Status: COMPLETED ·Phase: PHASE4
-
Predictives Factors of Cardiac Resynchronization Therapy: a Multimodal Analysis Using 2D Speckle Tracking Echocardiography Coupled With MIBG Myocardial Scintigraphy and Heart Failure Biomarkers
NCT02018029 ·Status: UNKNOWN
-
The Ability Of The PD2i Cardiac Analyzer To Predict Risk Of Ventricular Tachyarrhythmic Events
NCT00510731 ·Status: WITHDRAWN
-
A Prospective Randomised Multi-centre Trial Comparing cArdiac MRI Guided CRT Versus Conventional CRT Implantation in Patients With Ischaemic Cardiomyopathy
NCT03992560 ·Status: RECRUITING ·Phase: NA
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
BIO|CONCEPT.BIOMONITOR-HF Collect Clinical Data From Heart Failure Patients Using BIOMONITOR Devices With a Study Specific Research Software
NCT06989580 ·Status: RECRUITING ·Phase: NA
-
Evaluating Infrasonic Hemodynography
NCT04636892 ·Status: RECRUITING ·Phase: NA
-
Echocardiography Guided Cardiac Resynchronization Therapy (EchoCRT)
NCT00683696 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
PREVENT-HF: Prevention of Heart Failure Events With Impedance Cardiography Testing
NCT00409916 ·Status: UNKNOWN ·Phase: PHASE4
-
Dual-Site LV Pacing in CRT Non Responders: Multicenter Randomized Trial
NCT01059175 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation Of Exercise-Induced Cardiac Conduction Instability In Predicting Ventricular Fibrillation Events In Hypertrophic Cardiomyopathy
NCT04157205 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
CORE: Study to Evaluate the Conducted AF-Response-Algorithm in Patients Suffering From Heart Failure and Atrial Fibrillation
NCT00170313 ·Status: TERMINATED ·Phase: PHASE4
-
Survey of QRS Frequency at Various Left Ventricular Pacing Sites for Cardiac Resynchronization
NCT03253809 ·Status: TERMINATED ·Phase: NA
-
Wireless Handheld 8-lead ECG Device Performance in Heart Patients (Rapid Rhythm)
NCT03501836 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Device Risk Management of Atrial Fibrillation and Heart Failure
NCT01486316 ·Status: COMPLETED ·Phase: NA
-
Biventricular Versus Right Ventricular Pacing in Heart Failure Patients With Atrioventricular Block (BLOCK HF)
NCT00267098 ·Status: COMPLETED ·Phase: NA
-
A Novel Healthcare Information Technology Tool to Improve Care in Patients With Atrial Fibrillation
NCT02623517 ·Status: COMPLETED