Using Flexible Resin in Maxillary Obturators
NCT02482064 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2016-06-10
Summary
Ten patients who had had maxillectomy will be assigned to two groups employing two types of 'temporary obturators. The obturators in the first group will be made from heat cure acrylic resin, whereas those in the second group from flexible resin.
A comparison will be made between the two materials in terms of oral-nasal seal using the drinking water test as well as the mirror test.
Conditions
- Patients Who Had Undergone Partial or Complete Maxillectomy
Interventions
- OTHER
-
Flexible resin
This material 'Flexible resin' is going to be used in the construction of the 'flexible obturators'.
Sponsors & Collaborators
-
Damascus University
lead OTHER
Principal Investigators
-
Huda Yahia, DDS · MSc student, Removable Prosthodontic Department, University of Damascus Dental School
-
Eyad Al-Shaarani, DDS MSc PhD · Professor of Removable Prosthodontics, University of Damascus Dental School
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 10 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-05-31
- Primary Completion
- 2016-03-31
- Completion
- 2016-05-31
Countries
- Syria
More Related Trials
-
Evaluation of Three Hard Relining Materials in Complete Dentures
NCT02203279 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and Microbial Changes in Complete Dentures.
NCT03043456 ·Status: UNKNOWN ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
Microbiological Study on Maxillary Complete Dentures of Two Different Materials
NCT02950623 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
NCT04539210 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Using 3D Printed PEEK Facial Implants in Repairing Maxillofacial Deformities
NCT05348434 ·Status: COMPLETED
-
Soft Tissue Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Casted
NCT04543864 ·Status: UNKNOWN ·Phase: NA
-
Compressive Single-piece Implants for Immediate Rehabilitation of Edentulous Maxillectomy Patients
NCT06572891 ·Status: COMPLETED ·Phase: NA
-
Retention of Metal Reinforced Polyamide Denture Base and Heat Cured Acrylic Resin Denture Base in Complete Mandibular Denture
NCT03385746 ·Status: UNKNOWN ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Single-retainer Lithium Di-silicate Versus Zirconia Resin Bonded Bridge for Replacement of an Anterior Missing Tooth.
NCT05861921 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
Using Two Different Attachments in Mandibular Implant Overdenture Cases in Order to Retention and Patient Satisfaction
NCT06678945 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture
NCT05585008 ·Status: COMPLETED ·Phase: NA
-
Management of Loading Forces Distribution in Mandibular Distal-extension Prostheses
NCT02178384 ·Status: COMPLETED ·Phase: NA
-
Conventional One-piece Versus Two-piece Magnet-retained Obturators
NCT05066828 ·Status: COMPLETED ·Phase: NA
-
Initial Stability of Posterior Maxillary Implants With Bicortical Fixation
NCT01237184 ·Status: COMPLETED
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Technique for Border Molding in Complete Dentures Using Light-Cured
NCT04853459 ·Status: COMPLETED ·Phase: NA
-
IMMEDIATE IMPLANT With Different Types of Membranes
NCT06657651 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Conventional Versus 3D Printing Duplication Techniques of Complete Denture
NCT06588140 ·Status: COMPLETED ·Phase: NA