A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz Tonometer
NCT02475343 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1000
Last updated 2015-11-18
Summary
This study aims to use Schiotz tonometer to evaluate the corneal biomechanical properties. The administration of Schiotz tonometer is according to the routine protocol which is use to measure intra-ocular pressure. The results obtained from Schiotz tonometer will be compared with results obtained from ORA and/or Corvis.
Conditions
- Keratoconus
Interventions
- DEVICE
-
Schiotz tonometer
The corneal biomechanical properties will be measured using a Schiotz tonometer with routine manipulation protocol.This measurement will be used in normal people, keratoconic patients, patients received keratoplasty.
- DEVICE
-
UVA/riboflavin
The UVA/riboflavin corneal crosslinking will be applied using a UV-X lamp (Peschke Meditrade GmbH, Switzerland) with routine manipulation protocol (3mW/cm2, 365nm, 30 minutes).This treatment will be used in keratoconic patients.
- DEVICE
-
femto-LASIK
The keratoplasty mainly include femto-LASIK (Laser in situ keratomileusis), which will be applied using a Wavelight FS200 and Wavelight EX500 Excimer Laser (Alcon Inc. USA.).The keratoplasty will be applied in patients who would like to receive the surgery.
- DEVICE
-
Tomey SP-100 Pchymeter , Topolyzer Vario
Cornea thickness will be measured with a pachymeter (Tomey SP-100 Pchymeter, Japan); cornea topography will be measured with Topolyzer Vario (Allegro, Wavelight GmBH, Germany); anterior chamber depth, white to white, and ocular axis length will be measured using a IOL master (Carl Zeiss Meditec, Germany). These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
- DEVICE
-
Topcon CT-80, Topcon, Japan
Vision acuity will be measured with a decimal visual chart; IOP (Intra-ocular pressure) will be measured with a tonometer (Topcon CT-80, Topcon, Japan) , fundoscopy examination will be apllied with a direct ophthalmoscopy, slit lamp examination will be applied with a slit lamp. These examinations will be used in normal people, keratoconic patients, patients received keratoplasty.
- DEVICE
-
Corvis-ST
Cornea biomechanical properties will be measured with a ocular response analyzer (Reichert, USA.) and/or a Corvis-ST (Oculus, Germany).These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
Sponsors & Collaborators
-
Zhiwei Li
lead OTHER_GOV
Principal Investigators
-
Guoying Mu, MD. · Shandong Provincial Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2015-02-28
- Primary Completion
- 2016-05-31
- Completion
- 2016-06-30
Countries
- China
Study Locations
More Related Trials
-
Corneal Biomechanics, Optical Properties and Anterior Segment Structural Features in Patients With Pseudoexfoliation
NCT06731530 ·Status: RECRUITING
-
Evolution of a Novel Optical Coherence Tomography Based Index in Diagnosing Keratoconus
NCT06152484 ·Status: RECRUITING
-
Computer-aided Diagnosis of Ocular Diseases Based on Corneal Biomechanics
NCT04475900 ·Status: COMPLETED
-
Cross Linking Corneal Biomechanical Evaluation of CATS Tonometer Prism
NCT04180111 ·Status: UNKNOWN
-
Evaluation of the Change in the DA Ratio, IR and SSI as Parameters of Corneal Biomechanics Post Different LVC Procedures
NCT05377099 ·Status: COMPLETED ·Phase: NA
-
Brillouin Microscopy Used to Evaluate Corneal Mechanical Properties
NCT06914817 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Correlation Analysis Between Corneal Biomechanics and Anterior Segment
NCT06109636 ·Status: COMPLETED
-
Corneal Biomechanical Analysis Using Brillouin Microscopy
NCT04598932 ·Status: ENROLLING_BY_INVITATION
-
IOP Measurements Using ORA After ACXL in Keratoconus
NCT04464083 ·Status: COMPLETED
-
Icare Tonometry Effects on Keratometry Readings, Topography Readings, and Corneal Staining
NCT03275142 ·Status: COMPLETED ·Phase: NA
-
A 2-year Longitudinal Study on the Structural and Optical Effects of Orthokeratology Treatment on Eye
NCT02643342 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Two Devices for Measuring the Central Thickness of the Cornea Before and After Surgery (CECOT)
NCT02522416 ·Status: COMPLETED
-
How Astigmatism Influences Corneal Biomechanics and Intraocular Pressure
NCT03162471 ·Status: COMPLETED
-
EVALUATION of CATS TONOMETER PRISM in LASIK SUBJECTS
NCT06266351 ·Status: COMPLETED
-
Intraocular Lens Power Calculation for Combined Phaco-vitrectomy Procedures
NCT03856346 ·Status: UNKNOWN
-
Optimizing the Assessment of Refractive Outcomes After Cataract Surgery
NCT02842151 ·Status: COMPLETED ·Phase: NA
-
Measurement of High Order Aberrations in Late Stages Keratoconus
NCT01295164 ·Status: TERMINATED ·Phase: NA
-
Evaluation of the Keratoconic Cornea After Corneal Collagen Cross Linking.
NCT03879421 ·Status: UNKNOWN ·Phase: NA
-
Agreement and Accuracy of Different Devices Corneal Measurements
NCT04383366 ·Status: COMPLETED
-
Corneal Sensitivity Cross-linking Keratoconus
NCT01743443 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Analysis of Topographic Corneal Parameters
NCT06220578 ·Status: COMPLETED
-
Influence of Trabeculectomy and Phaco-trabeculectomy on Corneal Astigmatism
NCT02945202 ·Status: UNKNOWN ·Phase: NA
-
Corneal Biomechanics With Hydration in Normal and LASIK Eyes
NCT01183702 ·Status: COMPLETED ·Phase: NA
-
Pilot Study to Investigate the Feasibility, Reliability and Efficacy of Utilizing OCT to Automate PROSE Fitting
NCT04649177 ·Status: COMPLETED ·Phase: NA
-
Comparison of Corneal Stromal Tissue Consumption (LATAC)
NCT02519673 ·Status: COMPLETED