Measurements of Corneal Biomechanical Properties Using a Dynamic Scheimpflug Analyzer for Normal Adults in South Korea
NCT02627170 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 250
Last updated 2016-05-19
Summary
The human cornea is affected by the magnitude and velocity of both internal and external forces because the cornea has both static and dynamic resistance components. Considering these natures of the human cornea, many investigators have tried to demonstrate corneal biomechanical properties to understand these characteristics of the cornea. Corneal biomechanical properties are known to influence the accuracy of measurements in intraocular pressure (IOP) and are recognized as important factor to explain the susceptibility of development of glaucomatous damage. Until recently, the only instrument which enabled the in vivo measurements of the ocular biomechanical properties was ocular response analyzer (ORA, Reichert Ophthalmic Instruments, Depew, NY, USA).8 The ORA has been used to assess the biomechanical properties of the cornea according to the dynamic bidirectional applanation process. A dynamic Scheimpflug analyzer (corneal visualization Scheimpflug technology \[Corvis ST\], OCULUS, Wetzlar, Germany) has been introduced recently and has become a useful instrument for evaluating corneal biomechanical properties. The dynamic Scheimpflug analyzer captures the dynamic process of corneal deformation caused by an air puff using an ultra-high-speed Scheimpflug camera at a rate of up to 4,330 images per second. Until now, well-organized analysis on the normative data of the corneal biomechanical profiles measured with the dynamic Scheimpflug analyzer has not been reported yet. Hence, in the present study, we aim to conduct normative data analysis for the corneal biomechanical properties with the dynamic Scheimpflug analyzer in South Korea.
Conditions
- Healthy
Interventions
- DEVICE
-
dynamic Scheimpflug analyzer (corneal visualization Scheimpflug technology [Corvis ST], OCULUS, Wetzlar, Germany)
Sponsors & Collaborators
-
Yonsei University
lead OTHER
Eligibility
- Min Age
- 20 Years
- Max Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2015-12-31
- Primary Completion
- 2016-03-31
- Completion
- 2016-03-31
Countries
- South Korea
Study Locations
More Related Trials
-
Brillouin Microscopy Used to Evaluate Corneal Mechanical Properties
NCT06914817 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Multi-center Clinical Trial on Corneal Morphology Analysis in Chinese Population
NCT03010748 ·Status: UNKNOWN
-
Corneal Biomechanical Analysis Using Brillouin Microscopy
NCT04598932 ·Status: ENROLLING_BY_INVITATION
-
Accuracy of Curvature and Wavefront Aberrations of Posterior Corneal Surface, in Keratoconic and Post-CXL Corneas
NCT01527708 ·Status: COMPLETED
-
Evaluation of Morphology Abnormal Cornea Stability With Corneal Biomechanical
NCT05748002 ·Status: COMPLETED
-
Corneal Transplantation Guided by OCT RESCAN
NCT02736877 ·Status: UNKNOWN ·Phase: NA
-
Intraocular Lens Power Calculation for Combined Phaco-vitrectomy Procedures
NCT03856346 ·Status: UNKNOWN
-
Astigmatic Vector Analysis of Posterior Cornea - a Comparison Among Healthy, Forme Fruste and Overt Keratoconus Corneas
NCT02698709 ·Status: COMPLETED
-
IOL Power Calculation Using Dual Schiempflug Analyzer
NCT02362334 ·Status: UNKNOWN
-
Influence of Trabeculectomy and Phaco-trabeculectomy on Corneal Astigmatism
NCT02945202 ·Status: UNKNOWN ·Phase: NA
-
Dynamic Light Scattering and Keratoscopy for Corneal Examination
NCT00050466 ·Status: COMPLETED
-
Evaluation of Corneal Hysteresis and Corneal Resistance Factor After Corneal Cross-linking for Keratoconus
NCT01411384 ·Status: COMPLETED ·Phase: NA
-
Comparison of DCT, ORA and GAT in Eyes After Penetrating Keratoplasty
NCT00834782 ·Status: UNKNOWN
-
Agreement and Accuracy of Different Devices Corneal Measurements
NCT04383366 ·Status: COMPLETED
-
Wavefront Analyzes and Visual Performance of Three Multifocal Intra-ocular Lenses
NCT00876707 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Corneal Epithelial and Stromal Thickness Distribution in Keratoconus
NCT02023619 ·Status: COMPLETED
-
COMPARISON OF CORNEAL MEASUREMENTS IN NORMAL AND KERATOCONUS EYES USING ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY AND PENTACAM HR TOPOGRAPHER
NCT04462991 ·Status: COMPLETED
-
Accuracy of the Galilei Analyzer to Calculate the Effective Corneal Power After Corneal Refractive Surgery
NCT00934804 ·Status: TERMINATED ·Phase: NA
-
Pilot Clinical Evaluation of Approved Contact Lenses
NCT02540122 ·Status: COMPLETED ·Phase: PHASE1
-
How Astigmatism Influences Corneal Biomechanics and Intraocular Pressure
NCT03162471 ·Status: COMPLETED
-
Compare Anterior Chamber Biometry in Healthy and Post-LASIK Patients
NCT00838734 ·Status: UNKNOWN
-
Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations
NCT06278220 ·Status: NOT_YET_RECRUITING
-
Analysis of Influencing Factors of High-Order Aberrations of SMILE With Lenticule Retained
NCT06806085 ·Status: RECRUITING
-
Corneal Biomechanics With Hydration in Normal and LASIK Eyes
NCT01183702 ·Status: COMPLETED ·Phase: NA
-
Variability of Pentacam-derived Back Elevation Measurements in Keratoconus and Cross-linked Corneas
NCT01471873 ·Status: COMPLETED