Measurement of High Order Aberrations in Late Stages Keratoconus
NCT01295164 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 28
Last updated 2017-03-03
Summary
The instrument that will be used in the study is the Murcia monocular Adaptive Optics Visual simulator (AOVIS-I). The system provides an objective characterization of the optical quality of the patient's eye by application of wave-front sensing technology. The optical condition of every eye is represented by its wave aberration. This characterization overcomes the current description based only in refractive errors. This provides an accurate description of the optics of the eye based on the assessment of the whole set of ocular aberrations. The particular wave-front sensor is of a Hartmann-Shack type. One characteristics of this wave-front sensor is its high dynamic range allowing measuring highly aberrated eyes, such as patients with keratoconus.
Conditions
- Keratoconus
Interventions
- DEVICE
-
classic aberrometer and aberrometer AOVIS-1
Measurement of aberrations in early stages (1 and 2) of keratoconus as compared aberrometer AOVIS-1 with a "classic aberrometer".
- DEVICE
-
Aberrometer AOVIS-I
Measurement of aberrations in high stages (3 and 4) of keratoconus. Objective characterization of the optical quality of the patient eye by application of wave-front sensing technology in late stage keratoconus The complete procedure in one patient takes less than 5 minutes in only one consultation and is completely non invasive. The optical measurements only involve the use of low power infrared laser
Sponsors & Collaborators
-
University Hospital, Toulouse
lead OTHER
Principal Investigators
-
Francois Malecaze, MD · University Hospital, Toulouse
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-10-31
- Primary Completion
- 2012-11-30
- Completion
- 2012-11-30
Countries
- France
Study Locations
More Related Trials
-
Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations
NCT06278220 ·Status: NOT_YET_RECRUITING
-
Wavefront Guided Scleral Lenses for Keratoconus and Irregular Astigmatism
NCT04698590 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Early Feasibility Study of UV-Femtosecond Laser Assisted Lenticular Extraction
NCT03021707 ·Status: COMPLETED ·Phase: NA
-
Development of a Keratoconus Detection Algorithm by Deep Learning Analysis and Its Validation on Eyestar Images
NCT04763785 ·Status: UNKNOWN
-
A Comparison of Two Devices for Measuring the Central Thickness of the Cornea Before and After Surgery (CECOT)
NCT02522416 ·Status: COMPLETED
-
Optimizing the Assessment of Refractive Outcomes After Cataract Surgery
NCT02842151 ·Status: COMPLETED ·Phase: NA
-
Customized Contact Lenses
NCT05134909 ·Status: UNKNOWN ·Phase: NA
-
Optical Coherence Pachymetry to Evaluate Central Corneal Ablation Depth in Myopic Femtosecond Laser in Situ Keratomileusis
NCT02893644 ·Status: COMPLETED
-
A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz Tonometer
NCT02475343 ·Status: UNKNOWN ·Phase: NA
-
Risk Factors and Progression of Keratoconus
NCT05676580 ·Status: RECRUITING ·Phase: NA
-
Evolution of a Novel Optical Coherence Tomography Based Index in Diagnosing Keratoconus
NCT06152484 ·Status: RECRUITING
-
Analysis of Topographic Corneal Parameters
NCT06220578 ·Status: COMPLETED
-
Treatment of Keratoconus With Advanced CXL-II
NCT02514200 ·Status: UNKNOWN ·Phase: PHASE2
-
Astigmatic Vector Analysis of Posterior Cornea - a Comparison Among Healthy, Forme Fruste and Overt Keratoconus Corneas
NCT02698709 ·Status: COMPLETED
-
Comparison of Two Different Optical Biometric Systems
NCT05411341 ·Status: COMPLETED
-
Level of Agreement of Intraocular Lens Power Measurements Between IOLMaster and Verion
NCT03876782 ·Status: COMPLETED
-
Intraoperative Aberrometry vs Conventional Intraocular Lens Calculation, a Prospective Study.
NCT06219252 ·Status: RECRUITING ·Phase: NA
-
Assessment of Corneal Stiffness in Keratoconus After Crosslinking by Corvis ST and OCT.
NCT05161052 ·Status: UNKNOWN ·Phase: NA
-
The Effects of Contact Lenses With UV/HEV-Filter on Visual Function
NCT05601544 ·Status: COMPLETED ·Phase: NA
-
A Prospective Clinical Research Project Evaluating The Effects of Soft Contact Lenses on Higher Order Visual Aberrations
NCT00344864 ·Status: TERMINATED
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Validation of Innovative Scheimpflug Topography Derived RGP Contact Lens Designs In Optometry Network
NCT06312163 ·Status: COMPLETED
-
Measurements of Corneal Biomechanical Properties Using a Dynamic Scheimpflug Analyzer for Normal Adults in South Korea
NCT02627170 ·Status: COMPLETED
-
Accuracy of Curvature and Wavefront Aberrations of Posterior Corneal Surface, in Keratoconic and Post-CXL Corneas
NCT01527708 ·Status: COMPLETED
-
Comparison of Pre-operative Measurements With Intraoperative Aberrometry in Predicting Correction for Low Toric Lens Correction in Cataract Surgery
NCT04247152 ·Status: COMPLETED ·Phase: NA