Cardiac Vascular Reconstruction DynaCT for TAVI Procedures
NCT02031796 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 35
Last updated 2019-01-08
Summary
The purpose of this work is to evaluate the feasibility of a new Cardiac Vascular Reconstruction (CAVAREC, Siemens Medical Systems, Germany) image reconstruction algorithm for use during transcatheter aortic valve implant (TAVI) procedures or interventional procedures to treat congenital or structural heart disease. CAVAREC utilizes the same x-ray projection images as currently acquired for clinical DynaCT. X-ray image acquisition to allow CAVAREC will occur during the interventional procedure after the TAVI device, other valve, or stent is implanted. If the participants already have a surgically-implanted TAVI device, stent or other device, and are having a cardiac catheterization, then an extra set of images will be acquired after your clinical care is complete, but before you leave the procedure room. The CAVAREC image processing algorithm will be implemented on an off-line workstation after the interventional procedure is complete. After the TAVI procedure, CAVAREC images will be quantitatively and qualitatively compared to Siemens DynaCT and cardiac CT images from Radiology. The results of this study will be used to direct further development of CAVAREC toward the end goal of providing improved imaging capabilities to guide TAVI, congenital heart, or structural heart treatment procedures.
Conditions
- Aortic Valve Disease
Interventions
- OTHER
-
CAVAREC Image Processing algorithm
After deployment of the TAVI prosthesis, other trans catheter valve, or stent, but before the patient care episode is completed, a set of rotational x-ray angiography images will be acquired and reconstructed using the clinical DyanCT and research CAVAREC algorithms.
Sponsors & Collaborators
-
Siemens Medical Solutions USA - CSG
collaborator INDUSTRY - lead OTHER
Principal Investigators
-
Kenneth Fetterly, Ph.D. · Mayo Clinic
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-02-28
- Primary Completion
- 2017-10-13
- Completion
- 2017-10-17
Countries
- United States
Study Locations
More Related Trials
-
Detection of Proximal Coronary Artery Disease in the Work-up for Transcatheter Aortic Valve Implantation Using CTA (From the DEPICT CTA Database)
NCT04491513 ·Status: COMPLETED
-
CT TAVR Abdomen Study
NCT05758701 ·Status: RECRUITING ·Phase: PHASE4
-
Comparing Measurements of the Aortic Valve Taken During Surgery With Those Obtained Before Surgery Using Computed Tomography Scans, in Patients Undergoing Surgical Aortic Valve Replacement
NCT07125469 ·Status: RECRUITING ·Phase: NA
-
Optical Coherence Tomography (OCT) to Evaluate Cardiac Allograft Vasculopathy (CAV) in Patient's Post Heart Transplant
NCT01403142 ·Status: COMPLETED
-
Microvascular Cardiac Allograft Vasculopathy Trial
NCT05826444 ·Status: RECRUITING
-
Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis
NCT02628899 ·Status: COMPLETED ·Phase: NA
-
Use of Virtual Reality for Procedural Planning of Transcatheter Aortic Valve Replacement
NCT04944667 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
NCT01531374 ·Status: COMPLETED ·Phase: NA
-
Assessment of Paravalvular Leak After TAVI by Hemodynamic Measurements and Cardiac MRI
NCT04281771 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Subclinical Aortic Valve Bioprosthesis Thrombosis Assessed With 4D CT
NCT02426307 ·Status: ACTIVE_NOT_RECRUITING
-
CGA-TAVI Registry to Evaluate the Predictive Value of a CGA in Predicting TAVI Outcomes
NCT01991444 ·Status: COMPLETED
-
Interest of Cardiac Computed Tomography to Optimize and Improve the Procedure of TAVI
NCT01672268 ·Status: COMPLETED ·Phase: PHASE3
-
Remote Ischemic Preconditioning for Renal Protection in TAVI
NCT03347032 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of Neurocognition in Patients Undergoing Transcatheter Aortic Valve Replacement
NCT05614986 ·Status: COMPLETED
-
MRI in Transcatheter Aortic Valve Replacement Patients
NCT05603026 ·Status: RECRUITING ·Phase: NA
-
Transcaval Access for Transcatheter Aortic Valve Replacement in People With No Good Options for Aortic Access
NCT02280824 ·Status: COMPLETED ·Phase: PHASE1
-
Prospective Registry of Patients Undergoing Cardiac CT With NAEOTOM Alpha PCD-CT Before TAVI Procedure
NCT07016477 ·Status: RECRUITING
-
Safety & Efficacy Study of the Medtronic CoreValve® System-Treatment of Symptomatic Severe Aortic Stenosis With Significant Comorbidities in Extreme Risk Subjects Who Need Aortic Valve Replacement
NCT01675440 ·Status: COMPLETED
-
Endovascular Aortic Repair for Aortic Dissection
NCT01505309 ·Status: UNKNOWN ·Phase: NA
-
Effects of Aortic Valve Replacement on Myocardial T1 Values in Severe Aortic Valve Stenosis
NCT05404100 ·Status: COMPLETED
-
Aortic Valve and Root Measurements Under Real-Time 3-Dimensional Visualization During Angiography
NCT02073617 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Systemic Microcirculation of Patients Undergoing Heart Valve Surgery
NCT05728047 ·Status: COMPLETED
-
Aortic Stenosis Pre-Transcatheter Aortic Valve Replacement (TAVR) Procedure CT Scan
NCT01843426 ·Status: COMPLETED ·Phase: NA
-
REdo tranScatheter Aortic Valve Replacement for Transcatheter aOrtic Valve failuRE
NCT06777368 ·Status: RECRUITING
-
Assessment of Neurologic Injury Subsequent to Transcatheter Aortic Valve Replacement: A Feasibility Study
NCT01927601 ·Status: WITHDRAWN