Assessment of Paravalvular Leak After TAVI by Hemodynamic Measurements and Cardiac MRI
NCT04281771 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 92
Last updated 2024-01-19
Summary
Rationale: Transcatheter aortic valve implantation (TAVI) has become the standard therapy for elderly patients with high surgical risks. Paravalvular leakage after TAVI is relatively common and there is conflicting evidence regarding the clinical impact of mild paravalvular leakage in self-expanding devices. Prospective data for self-expanding devices are required to compare the extent of paravalvular leakage as a result of device design. Grading paravalvular leakage after TAVI is difficult. Echocardiography and angiography systematically underestimate paravalvular leakage (PVL) as compared to cardiac MRI. Hemodynamic measurements are used to aid decision making directly after TAVI implantation. Prospective data comparing hemodynamic measurements with cardiac MRI are needed to design an optimal strategy to grade paravalvular leakage peri-operatively in order to optimize TAVI outcomes. The combination of aortic valve stenosis, angiodysplasia and von Willebrand Disease type 2A (vWD-2A) is known as Heyde syndrome. Previous studies have shown a decrease in angiodysplastic lesions after TAVI. However, since PVL after TAVI is relatively common, angiodysplastic lesions tend to reoccur. Prospective data comparing the severity of PVL to the severity of both vWD-2A and angiodysplasia are lacking.
Objective: To assess procedural hemodynamic measurements in patients with paravalvular regurgitation quantified by means of cardiac MRI (CMR) and to analyse its association with impaired clinical outcome during 5-year follow-up. Secondary objectives are to assess whether the severity of vWD-2A correlates with the severity of PVL measured by cardiac MRI, and to prospectively assess the success percentage of TAVI in the treatment of angiodysplasia.
Study design: This is a prospective, single-center clinical trial. Patients will receive a TAVI. After implantation different hemodynamic indices of PVL will be assessed. Within 4-8 weeks after TAVI a cardiac MRI will be performed to quantify the amount of PVL. Standardized clinical follow-up will take place at discharge, 30 days, 3 months, 6 months and 1 year. Telephone follow-up will take place at 2, 3, 4 and 5 years after TAVI. In patients with known angiodysplasia or iron deficiency anemia e.c.i., a videocapsule endoscopy (VCE) will take place before TAVI and 6 months after TAVI. Of note, for the substudy on Heyde syndrome, patients with a different type of TAVI valve (i.e. no Abbott Portico valve) are also allowed to participate.
Study population: Approximately 80 patients with severe symptomatic aortic valve stenosis with an indication for TAVI will be included. At least 76 patients with a cardiac MRI that is of sufficient quality to quantify the amount of PVL will be included.
Intervention: Patients will undergo cardiac MRI on top of standard clinical care within 4-8 weeks after TAVI. A subgroup of patients will also undergo a VCE.
Main study parameters/endpoints: The primary endpoint is defined as PVL regurgitation fraction as measured by cardiac MRI. One secondary endpoint will comprise a composite of device success, early safety and clinical efficacy as defined by the Valve Academic Research Consortium-2 (VARC-2) (1) and will comprise death, vascular complications, stroke/TIA, life-threatening bleeding requiring transfusion, and acute kidney injury requiring dialysis. Another secondary endpoint will be the reduction of angiodysplastic lesions after TAVI as determined by VCE.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: The hemodynamic indices can be assessed in a standard fashion using a fluid filled pigtail catheter that is placed in the left ventricle as part of the routine protocol. Following TAVI, enrolled patients will undergo cardiac MRI to assess PVL. The risk of cardiac MRI after TAVI implantation is negligible. Extra blood samples will be taken. After one year, patients will be followed by telephonic follow-up. Risk/benefit: the expected benefit is a structured clinical follow-up at 1, 2, 3, 4 and 5 years, at the cost of an extra visit to undergo cardiac MRI.
Conditions
- Transcatheter Aortic Valve Replacement
- Hemodynamic Monitoring
- Aortic Valve Insufficiency
- Aortic Valve Stenosis
- Heyde's Syndrome
- Acquired Von Willebrand Disease
Interventions
- PROCEDURE
-
cardiac MRI
Patients are studied on a clinical 1.5 Tesla scanner with cardiac radiofrequency receiver coil centered over the heart, and ECG monitoring. The following parameters are assessed: Functional imaging: ECG-gated cine Steady-state free precession (SSFP) MRI images are obtained during repeated breath holds in long axis and short axis orientations covering the entire left ventricle. Global systolic and diastolic function are assessed, and left ventricular mass is calculated. Flow imaging: ECG-gated 2D flow measurements are assessed above the prosthetic valve, and at the level of the pulmonary trunk.
Sponsors & Collaborators
-
Radboud University Medical Center
lead OTHER
Principal Investigators
-
Niels van Royen, MD PhD · Radboud University Medical Center
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-09-17
- Primary Completion
- 2021-11-27
- Completion
- 2026-10-28
Countries
- Netherlands
Study Locations
More Related Trials
-
Reversibility of Cardiac Conduction Disturbances Following TAVI
NCT06481137 ·Status: RECRUITING ·Phase: NA
-
Prospective Registry of Patients Undergoing Cardiac CT With NAEOTOM Alpha PCD-CT Before TAVI Procedure
NCT07016477 ·Status: RECRUITING
-
Mechanisms of Excess Risk in Aortic Stenosis
NCT04627987 ·Status: RECRUITING
-
Right Ventricle Remodeling After Pulmonary Valve Replacement and Percutaneous Pulmonary Valve Insertion
NCT05090228 ·Status: COMPLETED
-
Hypothyroidism After the TAVI Procedure in Elderly Patients
NCT04831957 ·Status: RECRUITING ·Phase: NA
-
A Study to Obtain Imaging Data in 40 Patients Having Transcatheter Aortic Valve Implantation (TAVI)
NCT06596460 ·Status: RECRUITING ·Phase: NA
-
Optical Coherence Tomography (OCT) to Evaluate Cardiac Allograft Vasculopathy (CAV) in Patient's Post Heart Transplant
NCT01403142 ·Status: COMPLETED
-
Treatment of Concomitant Mitral Regurgitation by Mitral Valve Clipping in Patients With Successful Transcatheter Aortic Valve Implantation.
NCT04009434 ·Status: UNKNOWN ·Phase: NA
-
Microvascular Cardiac Allograft Vasculopathy Trial
NCT05826444 ·Status: RECRUITING
-
Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI)
NCT04437303 ·Status: COMPLETED ·Phase: PHASE4
-
Preoperative CT-imaging with Patient-specific Computer Simulation in Transcatheter Aortic Valve Replacement
NCT05788770 ·Status: RECRUITING ·Phase: NA
-
Observational Study on the Application of High-Flow Therapy After Percutaneous Transfemoral Aortic Valve Replacement
NCT04489914 ·Status: COMPLETED
-
MRI in Transcatheter Aortic Valve Replacement Patients
NCT05603026 ·Status: RECRUITING ·Phase: NA
-
Transcatheter Para-Valvular Leak Closures
NCT05117359 ·Status: COMPLETED
-
Prognostic Impact of the Evolution of PAH 3 Months After TAVI (HTP-TAVI)
NCT04008550 ·Status: TERMINATED ·Phase: NA
-
Assessments of Thrombus Formation in TAVI
NCT03248232 ·Status: COMPLETED
-
Mortality Post-TAVI and Correlation With Haemodynamic Parameters.
NCT03769545 ·Status: COMPLETED
-
Prediction of Reverse Remodeling and Outcome in Patients With Severe Secondary Mitral Valve Regurgitation Undergoing Transcatheter Edge-to-edge Mitral Valve Repair
NCT04913727 ·Status: RECRUITING ·Phase: NA
-
Post-surgical Aortic Hemodynamics After Aortic Valve Replacement
NCT03347851 ·Status: COMPLETED
-
4D- Flow- MRI After Aortic Valve Surgery
NCT04223713 ·Status: UNKNOWN ·Phase: NA
-
Conduction Abnormalities With Severe Aortic Stenosis Before and After Transcatheter Aortic Valve Replacement
NCT03180073 ·Status: COMPLETED
-
Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation
NCT01805739 ·Status: RECRUITING
-
18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome
NCT02304276 ·Status: COMPLETED ·Phase: NA
-
Endothelial Injury and Development of Coronary Intimal Thickening After Heart Transplantation
NCT01848301 ·Status: TERMINATED ·Phase: PHASE1
-
Impact of LVAD Implantation on Micro- and Macrovascular Function
NCT02174133 ·Status: COMPLETED