ELASTANCE: Prospective Physiological Study of Lung Elastance in Recruitment and Derecruitment in Early Onset Mechanically Ventilated ARDS Patients
NCT01899560 · Status: COMPLETED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 12
Last updated 2017-05-12
Summary
The recruitment strategy in Acute respiratory distress syndrome (ARDS) patients mechanically ventilated combines recruitment maneuvers and positive end expiratory pressure (PEEP). Recruitment maneuvers promote alveolar recruitment leading to increased end-expiratory lung volume in order to prevent repetitive opening and closing of unstable lung units and reduce the strain induced by ventilation. In addition, recruitment is effective in improving oxygenation. Variety of recruitment maneuver have been described, the most commonly used is the application of sustained continuous positive airway pressure at 40 cmH2O for 40 seconds. Staircase recruitment maneuver (SRM) is an alternative with good hemodynamic tolerance. Staircase recruitment maneuver (SRM) involves a progressive increase in positive end expiratory pressure (PEEP) (up to 40 cmH2O), in pressure control ventilation, in order to increase end-expiratory lung volume (EELV); then a decreasing PEEP trial is performed. The positive end expiratory pressure (PEEP) to prevent alveolar collapse depends on ratio between lung elastance and chest wall elastance. If chest wall elastance is high, the PEEP to obtain a positive end-expiratory transpulmonary pressure is high. The only way for the time being to know the transpulmonary pressure and the ratio between lung and chest wall elastance is the use of esophageal catheter. A non-invasive method for measuring the lung elastance by measuring volume recruited during a change of pressure (∆PEEP/∆EELV) could be used to avoid the use of esophageal catheter.
Conditions
- Acute Respiratory Distress Syndrome
Interventions
- PROCEDURE
-
Measure lung and chest wall elastance with esophageal catheter
Patients will be in supine position with 30-45° head of bed elevation. The cuff of the endotracheal tube will be transiently overinflated to 60 cmH2O to ensure there will be no air leaks. NMBA (cisatracurium) will be administrated \[9\]. The fraction of inspired oxygen (FiO2) will be adjusted for continuously monitored oxygen saturation (SpO2) between 90 to 94%. Patients will be ventilated in pressure control with 15 cmH2O of driving pressure. A low flow pressure/volume curve from 0 to 40 cmH2O will be performed.
- OTHER
-
non-invasive method for measuring the lung elastance
by measuring volume recruited during a change of pressure (∆PEEP/∆EELV)
Sponsors & Collaborators
-
Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-03-31
- Primary Completion
- 2013-06-30
- Completion
- 2014-11-27
Countries
- France
Study Locations
More Related Trials
-
Assessment of Lung Recruitablity of Acute Respiratory Distress Syndrome With SARS-CoV-2 Pneumonia by Electrical Impedance Tomography
NCT04473300 ·Status: COMPLETED
-
ARDS Esophageal Balloon Pressure Changes With Positioning Study
NCT03120793 ·Status: TERMINATED
-
Effects of Pleural Effusion Drainage on Respiratory System Mechanics
NCT01652521 ·Status: UNKNOWN
-
Pulmonary Overdistension Assessment With Electrical Impedance Tomography in Patients With Acute Respiratory Distress Syndrom in Prone Position.
NCT07090460 ·Status: RECRUITING
-
Personalized Ventilation Based on Ventilation-perfusion Mismatch and Lung Recruitability
NCT06430554 ·Status: RECRUITING
-
Measurement of Lung Elastance and Transpulmonary Pressure Using Two Different Methods (Lungbarometry)
NCT02948530 ·Status: UNKNOWN
-
Electrical Impedance Tomography Monitoring and Invasive Mechanical Ventilation During Pronation in Acute Respiratory Distress Syndrome.
NCT04605133 ·Status: UNKNOWN
-
Evaluation of the Diagnostic Performance of Electrical Impedance Tomography to Detect Situations at Risk of Lesions Induced by Conventional Mechanical Ventilation in ARDS
NCT02896673 ·Status: COMPLETED ·Phase: NA
-
Ventilator-induced Right Ventricular Injury During EIT-based PEEP Titration in Patients With ARDS
NCT05583461 ·Status: COMPLETED ·Phase: NA
-
Regional Lung Opening and Closing Pressures in Patients With Acute Lung Injury
NCT01107847 ·Status: UNKNOWN ·Phase: NA
-
Pressure Opening With Electrical Impedance Tomography
NCT05825534 ·Status: UNKNOWN ·Phase: NA
-
Use of Transient Elastogaphy to Assess Diaphragm Function in Mechanically Ventilated Patients
NCT03832231 ·Status: COMPLETED ·Phase: NA
-
Thoracic Fluid Content in Prediction of Failure of Weaning From Mechanical Ventilation
NCT03094390 ·Status: COMPLETED
-
V/Q Matching Variations With PEEP in ARDS According to Compliance-based Phenotypes (France)
NCT05578742 ·Status: RECRUITING ·Phase: NA
-
Post- End- Expiratory Pressure Affect the Alveolar Heterogeneity in Moderate and Sever ARDS Patients
NCT03763890 ·Status: UNKNOWN
-
Study of the Diaphragmatic Function by Transient Elastography (ELASTODIAPH)
NCT03313141 ·Status: COMPLETED ·Phase: NA
-
Early PP Monitored by EIT in Patients With ARDS
NCT05822869 ·Status: RECRUITING ·Phase: NA
-
Incremental and Decremental PEEP Titration by Diverse Strategies in Subjects with ARDS: a Prospective Physiological Study
NCT06808438 ·Status: COMPLETED
-
Electrical Impedance Tomography for Quantification of Pulmonary Edema in Acute Respiratory Distress Syndrome Patients
NCT02870894 ·Status: UNKNOWN
-
Combining Electrical Impedance Tomography and Thoracic Ultrasound Toinvestigate Dynamic Changes
NCT06958770 ·Status: NOT_YET_RECRUITING
-
Comparison of Different PEEP Titration Strategies Using Electrical Impedance Tomography in Patients With ARDS
NCT04247477 ·Status: COMPLETED ·Phase: NA
-
Ventilatory Monitoring in Children With Respiratory Distress Syndrome With Electrical Impedance Tomography
NCT03768921 ·Status: COMPLETED ·Phase: NA
-
Validation of Digital Chest-X-ray (CXR) to Assess Lung Recruitment in ARDS
NCT02081105 ·Status: TERMINATED ·Phase: NA
-
Eit in ArdS for Tcav Setting (EAST Study)
NCT06408272 ·Status: NOT_YET_RECRUITING
-
Electrical Impedance Tomography in One-Lung Ventilation
NCT03728010 ·Status: UNKNOWN