Validation of Digital Chest-X-ray (CXR) to Assess Lung Recruitment in ARDS
NCT02081105 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 38
Last updated 2022-01-11
Summary
Lung recruitability is essential for optimal Positive end-expiratory pressure (PEEP) selection in ARDS patients. It is defined as the potential for the non aerated or poorly aerated lung mass to become aerated due to the increase in airway pressure. PEEP contributes to lung recruitment mostly by maintaining some amount of the end-inspiratory recruitment at the end of expiration. PEEP also stabilizes patency of the small airways and minimizes the repeated opening and closing of them during the breathing cycle, which is implicated in a further lung inflammation. The gold-standard method for assessing lung recruitability is lung CT scan. For economic and feasibility this technique cannot be used in routine. Therefore, techniques that can be used at the bedside to measure lung recruitability are very well known. The measurement of recruited lung volume (Vrec) by using pressure-volume curve generated by the ventilator is another reference method to approach lung recruitment. It can be done at the bedside. Chest-X-Ray (CXR) is an interesting option as done in routine in this setting. Furthermore, it allows quantifying aeration thanks numerical image processing and a regional approach. In a preliminary one-center study we found a significant negative correlation between the amount of Vrec and the reduction in lung density measured by digital CXR between 5 and 15 cm H2O PEEP. In present study we would like to extend this previous result on a larger number of patients in a multicenter investigation.
Conditions
- Acute Respiratory Distress Syndrome (ARDS)
Interventions
- OTHER
-
PEEP of 5 or 15 cm H2O
PEEP of 5 or 15 cm H2O set at the respirator and applied to the patient for 10 minutes. Then, measurements are made at each PEEP in the following order: arterial blood gas, CXR, pressure-volume curve.
Sponsors & Collaborators
-
Hospices Civils de Lyon
lead OTHER
Principal Investigators
-
Hodane Yonis, MD · Hospices Civils de Lyon
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-02-28
- Primary Completion
- 2017-01-31
- Completion
- 2017-02-28
Countries
- France
Study Locations
More Related Trials
-
Electrical Impedance Tomography-Based Prognostic Model for ARDS
NCT06967207 ·Status: RECRUITING
-
Effect of EIT-guided PEEP Titration on the Prognosis of Patients with Moderate to Severe ARDS
NCT05207202 ·Status: COMPLETED ·Phase: NA
-
EIT Assessment of Overdistension in ARDS Patients in Prone Position
NCT06536543 ·Status: RECRUITING
-
Physiological Effects of Lung Impedance Tomography-Guided and Plat Pressure-Guided Phigh During APRV in Patients With ARDS
NCT06696638 ·Status: RECRUITING ·Phase: NA
-
PEEP Titration and Lung Recruitment Potential Assessed by 3D EIT
NCT06594601 ·Status: RECRUITING
-
Personalized Ventilation Based on Ventilation-perfusion Mismatch and Lung Recruitability
NCT06430554 ·Status: RECRUITING
-
Evaluation of the Diagnostic Performance of Electrical Impedance Tomography to Detect Situations at Risk of Lesions Induced by Conventional Mechanical Ventilation in ARDS
NCT02896673 ·Status: COMPLETED ·Phase: NA
-
Improvement of ARDS Ventilation-perfusion Matching by Prone Positioning Assessed by EIT
NCT05765760 ·Status: COMPLETED
-
Association Between EIT and CT During PEEP Titration in Patients With Acute Respiratory Failure
NCT07175194 ·Status: RECRUITING
-
Effect of Electric Impedance Tomography-Guided PEEP Titration
NCT05736185 ·Status: COMPLETED ·Phase: NA
-
Individualized PEEP Setting by EIT in Patients With ARDS
NCT02361398 ·Status: COMPLETED ·Phase: NA
-
Ultra-protective Ventilation Monitored by Electrical Impedance Tomography in Patients With Severe Acute Respiratory Distress Syndrome on Veno-venous ECMO
NCT05717218 ·Status: RECRUITING ·Phase: NA
-
V/Q Matching Variations With PEEP in ARDS According to Compliance-based Phenotypes (France)
NCT05578742 ·Status: RECRUITING ·Phase: NA
-
ARDS Esophageal Balloon Pressure Changes With Positioning Study
NCT03120793 ·Status: TERMINATED
-
Titration of PEEP During Mechanical Ventilation in Patients With ARDS Using Electrical Impedance Tomography.
NCT02596178 ·Status: WITHDRAWN ·Phase: NA
-
Assessment of Lung Recruitablity of Acute Respiratory Distress Syndrome With SARS-CoV-2 Pneumonia by Electrical Impedance Tomography
NCT04473300 ·Status: COMPLETED
-
Lung Response to a Higher PEEP During Severe Pneumonia: a CT Study
NCT07112976 ·Status: COMPLETED
-
Electrical Impedance Tomography: Collapse in Dependent Areas as a Predictor of Response to Prone Position Ventilation in COVID-19 Acute Respiratory Distress Syndrome
NCT04603755 ·Status: COMPLETED
-
Electrical Impedance Tomography Monitoring and Invasive Mechanical Ventilation During Pronation in Acute Respiratory Distress Syndrome.
NCT04605133 ·Status: UNKNOWN
-
Impact of Belt Position on the Results of PEEP Titration by EIT During ARDS
NCT06541522 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Dead Space Monitoring With Volumetric Capnography in ARDS Patients
NCT02889770 ·Status: COMPLETED
-
Assessing Lung Inhomogeneity During Ventilation for Acute Hypoxemic Respiratory Failure
NCT03589482 ·Status: COMPLETED ·Phase: NA
-
Determine the Effect of Prone Positioning in Adults With ARDS by Electrical Impedance Tomography
NCT04725227 ·Status: UNKNOWN
-
Monitorings the Physiological Mechanism of Airway Pressure Release Ventilation in ARDS Patients by EIT
NCT05406427 ·Status: UNKNOWN
-
A Comparison of Optimal PEEP Determination Guided by EIT and G5 Device in Moderate and Severe ARDS Patients
NCT03112512 ·Status: COMPLETED ·Phase: NA