Cemented Marathon/Corail Versus Pinnacle/Corail
NCT01693627 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 61
Last updated 2016-02-24
Summary
A randomised, comparative, prospective, single-blinded trial of two hip prosthesis:
1. Marathon cemented all-poly acetabular cup(Depuy, Warsaw, Indiana), Corail uncemented femoral stem(Depuy, Warsaw, Indiana), 32mm Alumina Biolox Forte femoral head(Depuy, Warsaw, Indiana) and
2. Pinnacle/Marathon uncemented cup(Depuy, Warsaw, Indiana), Corail uncemented femoral stem(Depuy, Warsaw, Indiana), 32mm Alumina Biolox Forte femoral head(Depuy, Warsaw, Indiana)
There will be a further in-group randomisation to a Corail femoral stem with or without a collar, creating a number of 4 study-groups in total.
The aims of the study are:
* To compare polyethylene wear and migration of the moderately cross-linked Marathon polyethylene in a cemented version(Marathon) and in an uncemented cup(Pinnacle/Marathon)
* To evaluate micromigration and periacetabular bone mineral density of the 2 cups using radiostereometry(RSA)
* To evaluate the migration patterns and proximal femoral bone density changes around the Corail stems with and without a collar
Conditions
- Arthritis of the Hip
Interventions
- DEVICE
-
Pinnacle/Corail with collar
Uncemented THA using Pinnacle-100/Marathon XLPE(Depuy, Warsaw, IN) acetabular component and Corail(Depuy,Warsaw,IN)collared femoral stem with 32mm Alumina Biolox Forte(Depuy,Warsaw,IN). Tantalum beads will be inserted into periprosthetic bone.
- DEVICE
-
Marathon/Corail with collar
Reversed hybrid THA using cemented Marathon XLPE(Depuy,Warsaw,IN) acetabular component and an uncemented Corail(Depuy,Warsaw,IN)collared femoral component with 32 mm Alumina Biolox Forte(Depuy,Warsaw,IN)head. Tantalum beads will be inserted into periprosthetic bone.
- DEVICE
-
Pinnacle/Corail without collar
Uncemented THA using Pinnacle-100/Marathon XLPE(Depuy, Warsaw, IN) acetabular component and Corail(Depuy,Warsaw,IN)collarless femoral stem with 32mm Alumina Biolox Forte(Depuy,Warsaw,IN). Tantalum beads will be inserted into periprosthetic bone.
- DEVICE
-
Marathon/Corail without collar
Reversed hybrid total hip arthroplasty using cemented Marathon XLPE(Depuy,Warsaw,IN) acetabular component and an uncemented Corail(Depuy,Warsaw,IN)collarless femoral component with 32 mm Alumina Biolox Forte(Depuy,Warsaw,IN)head. Tantalum beads will be inserted into periprosthetic bone.
Sponsors & Collaborators
-
Haukeland University Hospital
lead OTHER
Principal Investigators
-
Leif I Havelin, MD, PhD · Department of Orthopeadic Surgery, Haukeland University Hospital, Bergen, Norway
-
Benedikt A Jonsson, MD · Department of Orthopeadic Surgery, Haukeland University Hospital, Bergen, Norway
-
Geir Hallan, MD, PhD · Department of Orthopeadic Surgery, Haukeland University Hospital, Bergen, Norway
-
Ove Furnes, MD, PhD · Department of Orthopeadic Surgery, Haukeland University Hospital, Bergen, Norway
-
Clara G Gjesdal, MD, PhD · Department of Rheumatology, Haukeland University Hospital, Bergen, Norway
-
Kristin Haugan, MA · Department of Orthopeadic Surgery, Trondheim University Hospital, Trondheim, Norway
-
Arne K Skredderstuen, MD · Department of Orthopeadic Surgery, Haukeland University Hospital, Bergen, Norway
-
Terje Stokke · Department of Radiology, Haukeland University Hospital, Bergen, Norway
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 30 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-01-31
- Primary Completion
- 2017-01-31
- Completion
- 2022-01-31
Countries
- Norway
Study Locations
More Related Trials
-
RSA-Study of Cemented Hip Prostheses With Five Different Articulations
NCT00698672 ·Status: UNKNOWN ·Phase: NA
-
A Comparative Study of Stem and Cup Fixation and Polyethylene Wear
NCT04064723 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Comparison of 32mm and 28mm Head Components in Alumina-alumina Total Hip Arthroplasty
NCT01098604 ·Status: COMPLETED ·Phase: PHASE4
-
Metal-metal Articulations Versus Standard 28 mm Cementless Total Hip Arthroplasty
NCT01113762 ·Status: UNKNOWN ·Phase: PHASE2
-
Randomized Controlled Study Comparing a Short Stem Hip Prosthesis With a Stem of Standard Length
NCT02983526 ·Status: COMPLETED ·Phase: NA
-
A Randomized Clinical Study Comparing a Fully-Coated Cementless Stem Versus a Cemented Stem for Total Hip Replacements
NCT00689689 ·Status: COMPLETED ·Phase: PHASE4
-
Wear and Migration in the Corin Mini-Hip/Metafix and ECIMA Polyethylene
NCT02174965 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Polyethylene Wear, Migration and Clinical Outcome in Total Hip Replacement
NCT02196792 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Randomised Single Centre Study to Compare the Long-term Performance of 4 Designs of the DePuy Ultima LX Stem in Primary Total Hip Replacement
NCT00208351 ·Status: TERMINATED ·Phase: PHASE3
-
Study Comparing Marathon Polyethylene and Enduron Polyethylene Acetabular Liners Used in Total Hip Arthroplasty
NCT01121146 ·Status: COMPLETED ·Phase: NA
-
Periprosthetic Bone Remodeling Around Uncemented Components in Total Hip Arthroplasty
NCT01319227 ·Status: UNKNOWN ·Phase: NA
-
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
NCT05773261 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Marathon and Enduron Polyethylene at Long-Term Follow-up
NCT02508428 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of Cemented and Cementless Prostheses for Unstable Intertrochanteric Fractures in the Elderly
NCT03193697 ·Status: COMPLETED ·Phase: NA
-
Selecting the Right Hip Prosthesis for Young Patients
NCT03279276 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
An Assessment of 4 Different Bearing Types in Hip Replacement Types to Analsye the Lowest Wear Rates of Polyethylene
NCT03900039 ·Status: COMPLETED ·Phase: NA
-
RCT Comparing the DEXA Results of the HA-Omnifit Versus the Symax Uncemented Hip Stem
NCT01695213 ·Status: COMPLETED ·Phase: PHASE4
-
Polymethyl Methacrylate and (PEGT/PBT) Centralizer by the Uncemented BIHAPRO THP
NCT00214760 ·Status: TERMINATED ·Phase: PHASE3
-
A Migration and Bone Density Study Comparing Hi-Fatigue Bone Cement and Palacos Bone Cement
NCT01289834 ·Status: COMPLETED ·Phase: NA
-
A Single Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Ceramic-on-ceramic Bearing in Primary Total Hip Replacement
NCT00872222 ·Status: TERMINATED ·Phase: PHASE4
-
Comparison of Ceramic-on-Ceramic and Ceramic-on-Highly-Cross-Linked Polyethylene Bearings
NCT01806766 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of a Short Uncemented Femoral Stem to a Similar Standard Uncemented Femoral Stem
NCT03500926 ·Status: UNKNOWN ·Phase: NA
-
Wear Measurements of E-Poly in an Uncemented THA With Either 32 or 36 mm Caput of Ceramics.
NCT00804388 ·Status: UNKNOWN ·Phase: NA
-
Comparing Collared and Collarless Femoral Stems in Primary Total Hip Arthroplasty
NCT07337642 ·Status: RECRUITING ·Phase: NA
-
Clinical and Radiographic Outcomes of the Corin Tri-Fit Total Hip Replacement
NCT02162186 ·Status: COMPLETED