To Compare Cemented Versus Screw-retained Implant-supported Single Crowns With Customized Zirconia Abutments
NCT01644630 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 34
Last updated 2020-11-06
Summary
The aim of this study is to test whether or not the use of screw-retained implant crowns on customized zirconia abutments results in biological, technical and esthetic outcomes similar to those obtained with cemented all-ceramic crowns on customized zirconia abutments, both made with a computer-aided design and manufacturing procedure (CAD/CAM).
The null-hypotheses is that marginal bone level change is equal at screw-retained and cemented crowns
Conditions
- Implant-supported Single Crowns
Interventions
- PROCEDURE
-
Cemented crowns
The final lithium disilicate crowns will be cemented with an adhesive cement after tightening the abutments with the torque indicated by the manufacturer and closing the screw access hole with white guttapercha. The abutment will be cleaned with ethanol. A retraction cord will be placed for cementation if indicated. The crown will be etched with hydrofluoric acid and subsequently silanized. A sufficient amount of cement will be filled in the crown without creating major excesses. When the crown is seated correctly, the cement will be light-cured for a few seconds to facilitate the removal of the now hard excess cement. \- Excess cement will be meticulously removed with a carbon scaler. The removal of all excess cement will be checked with an X-ray and by visual and tactile inspection.
- PROCEDURE
-
Screw-retained crowns
The screw-retained crowns will be inserted and tightened with the torque indicated by the manufacturer. The screw access hole will to be closed with white guttapercha and a composite filling (Filtek, 3M ESPE).
Sponsors & Collaborators
-
University of Zurich
lead OTHER
Principal Investigators
-
Daniel Thoma, Prof. Dr. · Clinic of Reconstructive Dentistry
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-07-27
- Primary Completion
- 2019-11-11
- Completion
- 2019-11-11
Countries
- Switzerland
Study Locations
More Related Trials
-
Comparison of Two Implant Prosthetic Pathways
NCT02905838 ·Status: COMPLETED ·Phase: NA
-
Retrospective Study on Clinical Performance of Screw-retained Implant Crowns
NCT04370314 ·Status: COMPLETED ·Phase: NA
-
Zirconia Implants for Replacement of a Single Tooth
NCT04695899 ·Status: ACTIVE_NOT_RECRUITING
-
Esthetic Outcome of 3D Printed Hybrid Ceramics as Final Restorations for Single Screw Retained Implant.
NCT07154602 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Cementation Techniques for Single-tooth Implant Crowns
NCT03581565 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Full Contour Zirconia Chairside CAD/CAM Crowns
NCT06173167 ·Status: RECRUITING ·Phase: NA
-
Zirconia Implants: Practice-based Evidence
NCT06314425 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Prospective Clinical Trial Evaluating Outcomes of Surveyed Zirconia Crowns
NCT06564337 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Customized CAD/CAM Titanium-Milled Abutments Vs. Custom Abutments Over Immediate Implants in Class II Extraction Sockets in the Esthetic Zone: a Randomized Controlled Clinical Trial
NCT06791655 ·Status: COMPLETED ·Phase: PHASE2
-
Bacterial Microleakage and Bone Loss in Internal Connection Dental Implants Based on the Type of Abutment Used in Zirconia Partial Fixed Prosthesis: in Vivo Study
NCT06156111 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Two Implants Versus One Implant With a Cantilever - a Randomized Controlled Clinical Trial
NCT01649531 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Occlusal Adjustment Material Removal on Monolithic Zirconia Blocks: An In Vitro Study
NCT07280130 ·Status: NOT_YET_RECRUITING
-
Accuracy of Two Methods of Making Impressions for Complete-arch Implant Supported Fixed Prosthesis
NCT06343441 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Implant Retained CAD-CAM Ceramic Crowns
NCT04773873 ·Status: COMPLETED ·Phase: NA
-
Additively Versus Subtractively Manufactured Implant Supported Fixed Dental Prostheses
NCT07090863 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Volumetric Analysis of Root Resorption With Mini-Screw Implant Anchorage-assisted Retraction of Maxillary Incisors
NCT02221206 ·Status: UNKNOWN ·Phase: NA
-
Resin-Cement Type Influence on Cement Remnants in Implant-Supported Restorations
NCT06711237 ·Status: COMPLETED ·Phase: NA
-
Wear Characteristics and Clinical Performance of Lithium Silicate Versus Monolithic Zirconia Crowns.
NCT03530020 ·Status: UNKNOWN ·Phase: NA
-
Clinical Investigation on Zirconia-ceramic Three-unit Bridges With CAD-on Veneering
NCT02175329 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Aesthetic Outcomes of the Single Crowns Supported by Tissue Level Implants
NCT02061930 ·Status: UNKNOWN
-
Partially-guided Protocol for Maxillary Overdentures Retained by Ti-Zr One-piece Mini Implants
NCT06081192 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: 5 Years Study
NCT04355325 ·Status: UNKNOWN ·Phase: NA
-
Bone Remodeling Around Implants With Two Different Surfaces Placed in Horizontally Augmented Bone
NCT04343066 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Oral Health-Related Quality of Life In Patients With Conventional Complete Dentures Versus Mini-Implant Retained Overdentures: A Randomized Clinical Trial
NCT07080164 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Single Implant Crowns Supported by Narrow or Standard Diameter Implants in Molar Sites
NCT07073196 ·Status: RECRUITING ·Phase: NA