Single Implant Crowns Supported by Narrow or Standard Diameter Implants in Molar Sites
NCT07073196 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2025-07-18
Summary
Standard dental implants require sufficient bone and spacing, which may not be available in all patients. To address these limitations, narrow diameter implants (≤3.5 mm) have been introduced as a less invasive alternative, especially useful for medically compromised patients or those avoiding bone grafts. However, narrow implants made of pure titanium have shown long-term biological and technical concerns.
The introduction of titanium-zirconium (TiZr) alloy has improved mechanical strength, and several studies have demonstrated favorable outcomes with narrow TiZr implants. Yet, evidence remains limited regarding their exclusive use in high-load posterior (molar) regions. Prior studies report conflicting failure rates, potentially linked to prosthetic design and occlusal forces, but lack quantitative analysis of bite forces or prosthetic angles.
Emergence angle, prosthetic platform width, and implant-abutment connection may all influence implant stability and peri-implant tissue health. A newly introduced TorcFit™ connection may offer better stress distribution and torque resistance, but its clinical relevance-especially in narrow implants used for molars-remains untested.
Conditions
- Dental Implants
Interventions
- PROCEDURE
-
Dental implant treatment (narrow implants)
Replacement of a missing molar tooth with a narrow dental implant
- PROCEDURE
-
Dental implant treatment (standard implants)
Replacement of a missing molar tooth with a standard dental implant
Sponsors & Collaborators
-
Mohammed Bin Rashid University of Medicine and Health Sciences
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-10-01
- Primary Completion
- 2028-02-01
- Completion
- 2029-12-01
Countries
- United Arab Emirates
Study Locations
More Related Trials
-
Clinical Efficacy of Angulated Screw-retained and Cemented Single Implant Crowns in Esthetic Region
NCT04539912 ·Status: COMPLETED ·Phase: NA
-
Crestal Bone Response to Narrow vs. Regular Tie-Base in Subcrestal Implants
NCT07196228 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Two Mini-implant Diameters in the Infra-zygomatic Crest Region.
NCT07337538 ·Status: RECRUITING ·Phase: NA
-
5-year Follow up Study on the Comparative Performance of Two-piece Zirconia and Titanium Implants
NCT05326880 ·Status: RECRUITING ·Phase: NA
-
One-piece and Two-piece Zirconia Abutments in Single Implant Crowns in Esthetic Region
NCT05583123 ·Status: UNKNOWN ·Phase: NA
-
Effect of Adding Zirconium Oxide Nanoparticles to Printable Implant Overdenture
NCT06116877 ·Status: COMPLETED ·Phase: NA
-
Comparative (Short vs. Standard) Length Implants in Early Stability Patterns.
NCT07162389 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Patient Satisfaction and Crestal Bone Changes Around One-piece Zirconia(Zr) and Titanium(Ti) in Implant-Retained Mandibular Overdenture
NCT06643975 ·Status: RECRUITING ·Phase: NA
-
Success of Zirconia and Stainless Steel Crowns for Permanent Molars
NCT05049694 ·Status: COMPLETED ·Phase: NA
-
Proximal Contact Tightness of Zirconia Crowns: Digital Intraoral Scanning vs Conventional Impressions
NCT07142746 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Study of Mandibular Dentures Immediately Loaded on Implants or Mini-implants
NCT03866031 ·Status: COMPLETED ·Phase: NA
-
Comparing 7 mm and 5 mm Implants Placed Immediately After Molar Extraction
NCT07041294 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparative Aesthetic Analysis Between Titanium and Ceramic Implants
NCT04707677 ·Status: COMPLETED ·Phase: NA
-
Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: 5 Years Study
NCT04355325 ·Status: UNKNOWN ·Phase: NA
-
Natural Dentition, Prosthesis and Antagonist Wear 3D Analysis
NCT05637619 ·Status: RECRUITING
-
Peri-implant Papillary Height Comparison in Microsurgically and Macrosurgically Placed Dental Implants
NCT04189328 ·Status: COMPLETED ·Phase: NA
-
Titanium Versus Soft Metal CAD/CAM Frameworks for All-on-4 Implant Supported Prosthesis
NCT06114966 ·Status: RECRUITING ·Phase: NA
-
Zirconia Implants for Replacement of a Single Tooth
NCT04695899 ·Status: ACTIVE_NOT_RECRUITING
-
Esthetic Outcome of 3D Printed Hybrid Ceramics as Final Restorations for Single Screw Retained Implant.
NCT07154602 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Evaluation of the Clinical Efficacy of Short Implants With Standard-Length Implants - a Randomised Controlled Trial
NCT06520332 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Submerged vs. Nonsubmerged Single Laser-microgrooved Dental Implants.
NCT03674762 ·Status: COMPLETED ·Phase: NA
-
Monolithic Zirconia Crowns for Single Implants in the Molar Region: a Multicenter Clinical Trial
NCT02272491 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Narrow and Regular Implants
NCT04572490 ·Status: COMPLETED
-
PROMs Comparing Digital & Conventional Workflows
NCT04986761 ·Status: COMPLETED ·Phase: NA
-
Partially-guided Protocol for Maxillary Overdentures Retained by Ti-Zr One-piece Mini Implants
NCT06081192 ·Status: NOT_YET_RECRUITING ·Phase: NA