Efficiency Study Evaluating the Use of PVAC Catheter Technology for Performing Ablation in Pts With Atrial Fibrillation

NCT01562912 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 230

Last updated 2018-03-29

No results posted yet for this study

Summary

Atrial fibrillation (AF) is the most common arrhythmia affecting the Canadian population. AF is associated with increased risk of stroke,HF, and even mortality. AF can cause debilitating symptoms, adversely affect patient's (pt's) quality of life and functional status. Hence a strategy of sinus rhythm (SR) may be pursued over a strategy of allowing AF to persist. Percutaneous catheter ablation is an effective alternative to antiarrhythmic drugs (AAD) for maintaining SR. The success rate of PV isolation off AAD is about 80-90% in pt's with PAF, but repeat procedures are required in up to 40% of pt's. After one ablation, the success rate may only be 50-70% off drugs.Current standard ablation procedures for PV antral isolation employ mapping systems which reconstructions of the LA and PV anatomy are created. Visualization may be supplemented by integration of CT/ MRI images and/or intracardiac echocardiography. Robotic navigation has been employed to assist in ablation. Based on single point unipolar radiofrequency (RF) ablation catheter where lesions are created point-by-point around the PVs to obtain electrical isolation.This results in lengthy complex, costly procedures,often more than 4 hours, which requires high degree of operator skill.Creation of contiguous, transmural lesions is challenging with standard single-point RF. A novel multipolar catheter ablation system has been evaluated for achieving PV isolation (PVAC catheter, Medtronic Inc.) An over-the-wire circular mapping/ablation catheter can be advanced into the PV antrum, and multiple lesions around the circumference of the catheter can be delivered simultaneously using duty-cycled unipolar and bipolar RF energy. Early reports, the system can achieve complete PV isolation with reduced fluoroscopy and procedural times using lower powers to achieve more reliable lesion sets.Long-term efficacy also seems comparable to standard RF ablation.This novel technology has potential to broaden the application of AF ablation, making procedures less time-consuming, less complex without compromising procedural efficacy. Published data PVAC technology outcomes are limited to studies with small sample sizes of 12-102 pt's. Data has been restricted to a small number of European centers performing moderate numbers of PVAC procedures. There is no prospective, multicenter data. Little is known about the efficiency of PVAC procedures, allowing for an assessment of cost-effectiveness in using this technology.

Conditions

Interventions

DEVICE

Radiofrequency Ablation Procedure

Application of radiofrequency energy will be delivered during PV antral isolation procedure and should be performed with a standard, open irrigated ablation catheter and a mapping system as the investigator would perform the procedure normally.

DEVICE

PVAC Ablation Procedure

Application of radiofrequency energy with the Pulmonary Vein Ablation Catheter(PVAC)to eliminate potentials arising from the pulmonary veins.

Sponsors & Collaborators

  • Medtronic

    collaborator INDUSTRY
  • Newmarket Electrophysiology Research Group Inc

    lead OTHER

Principal Investigators

  • Atul Verma, MD · Newmarket Electrophysiology Research Group

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-02-29
Primary Completion
2017-12-31
Completion
2018-03-31

Countries

  • Canada

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.