Cardiac Magnetic Resonance Imaging Guided Left Ventricular Lead Placement
NCT01417624 · Status: UNKNOWN · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 70
Last updated 2011-08-16
Summary
Heart failure is a common, costly, disabling and potentially lethal condition. Despite well recognised and proven drug therapies, many patients remain breathless on exertion. A special pacemaker (cardiac resynchronisation therapy) may help improve symptoms of breathlessness and survival by restoring coordinated beating of the heart. However, despite careful planning and the knowledge of the most appropriate selection criteria, up to a third of patients do not get the desired beneficial effects after the pacemaker has been implanted.
The implantation of the special pacemaker requires three leads (wires) to be inserted within the heart. Currently this is undertaken under X-ray guidance. Some patients may have scarring of the heart muscle due to previous heart attacks or their underlying condition. The X-ray technique cannot see this and therefore the doctor may implant the lead in such an area of scar tissue. Cardiac magnetic resonance imaging (CMR) can demonstrate these areas of scar. The study aims to investigate whether CMR can better predict where the wires should be placed. The CMR pictures will be taken before the patient has the special pacemaker implanted.
Conditions
Interventions
- OTHER
-
CMR Guidance in terms of guiding LV lead implantation
Following randomisation, the optimal position of the LV lead will be determined either according to current standard criteria (as proposed by the primary operator) or with CMR guidance. The CRT device will be implanted using established conventional techniques. The CMR study will be performed pre-implantation only. The distribution of myocardial scar and fibrosis will be derived from this study. A CMR venogram will also be generated and the suggested optimal venous tributaries of the great cardiac vein will be identified from discussion between the principal investigator and senior CMR physician. This information will be used for those in the active arm only.
Sponsors & Collaborators
-
Royal Brompton & Harefield NHS Foundation Trust
lead OTHER
Principal Investigators
-
Rakesh Sharma, MRCP PhD · Royal Brompton & Harefield NHS Foundation Trust
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-08-31
- Primary Completion
- 2012-12-31
- Completion
- 2013-06-30
Countries
- United Kingdom
Study Locations
More Related Trials
-
LV Endocardial Cardiac Resynchronisation Therapy
NCT02174289 ·Status: UNKNOWN ·Phase: NA
-
Optimal Left Ventricular Lead Positioning During Cardiac Resynchronisation Therapy; Comparison of Two Methods of Targeting
NCT03769272 ·Status: UNKNOWN
-
Application of Right Atrial Left Ventricular Fusion Pacing in Patients With CRT Indications
NCT03071978 ·Status: COMPLETED ·Phase: NA
-
Image Supported Lead Placement in CRT
NCT05053568 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CRT In Narrow QRS Heart Failure: Mechanistic Insights From Cardiac MRI And Electroanatomical Mapping
NCT03258060 ·Status: TERMINATED ·Phase: NA
-
Optimal Coronary Sinus Lead Implantation Using Intracardiac Impedography and Magnetic Resonance Imaging
NCT01129635 ·Status: COMPLETED ·Phase: NA
-
InterventiOn of Biventricular Pacemaker Function on ventrIcular Function Among Patients With LVAD's
NCT03232736 ·Status: COMPLETED
-
Predicting Response to Cardiac Resynchronization Therapy in Heart Failure
NCT00359372 ·Status: COMPLETED
-
Response to Cardiac Resynchronization Therapy of Previously Right Ventricular Paced Heart Failure Patients
NCT01466621 ·Status: COMPLETED
-
Left Bundle Branch Pacing on Outcomes and Ventricular Remodeling in Biventricular CRT Nonresponders
NCT05760924 ·Status: RECRUITING ·Phase: NA
-
Cardiac Resynchronisation Study
NCT01213537 ·Status: COMPLETED
-
Correlating QLV Interval to Left Ventricular (LV) Lead Position in Patients Receiving Cardiac Resynchronization Therapy.
NCT02166762 ·Status: COMPLETED ·Phase: NA
-
Left Bundle Branch Pacing Versus Biventricular Pacing for Cardiac Resynchronization Therapy
NCT04110431 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study of Interventricular Septal Puncture for Cardiac Resynchronization Therapy to Treat Heart Failure
NCT01818765 ·Status: COMPLETED ·Phase: NA
-
Impact of Cardiac Resynchronization Therapy on Right Ventricular Function in Left Ventricular Assist Device Patients
NCT02169076 ·Status: WITHDRAWN ·Phase: NA
-
Novel Vascular Biomarkers Behaviour and Clinical Value in Heart Failure and CRT
NCT02541773 ·Status: UNKNOWN
-
ConTempoRary Cardiac Stimulation in Clinical practicE: lEft, BivEntriculAr, Right, and conDuction System Pacing
NCT06324682 ·Status: RECRUITING
-
Observation of ImageReady™ MR Conditional Pacing System in China
NCT02636712 ·Status: COMPLETED
-
Post-market Study of Multi-Vector Left Ventricular Lead Performance in Chinese Patients With Chronic Heart Failure
NCT02367716 ·Status: COMPLETED
-
Developing a New, Dynamic, Therapeutic Pacemaker Algorithm for Stabilising Periodic Breathing in Chronic Heart Failure.
NCT01044407 ·Status: UNKNOWN ·Phase: PHASE2
-
Implantable Cardioverter Defibrillators And Magnetic Resonance Imaging of the Heart at 1.5 Tesla
NCT00356239 ·Status: UNKNOWN
-
Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac Resynchronization Therapy
NCT01323686 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
Clinical Study of LBBP
NCT04919447 ·Status: UNKNOWN
-
Physiological Versus Right Ventricular Outcome Trial Evaluated for Bradycardia Treatment Upgrades
NCT06052475 ·Status: RECRUITING ·Phase: NA