Prospective Study Comparing Methods of Obtainment of Specimen After EUS-FNA in Patients With Peri-pancreatic Mass
NCT01354795 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2011-05-17
Summary
EUS-guided FNA has been proved to be a safe and useful method for tissue sampling of gastrointestinal track lesions and other organ lesions including mediastinal and intra-abdominal lymph nodes, pancreas and hepatobiliary tree. The usefulness of EUS-FNA depends on several factors. For example, experience of the endosonographers, adequate sampling, sample preparing, accurate interpretation by the cytopathologist and on-site cytopathology interpretation. However, in many hospitals, no cytopathologist can be present during EUS-FNA. Therefore, determining appropriate methods to obtain and prepare EUS-guided FNA are important to make correct a diagnosis without on-site cytopathologist.
Suction with a self-retracting 10-mL syringe will likely bring in more cellularity but also more blood. Some endosonographers use no suction, others use constant suction. Usually specimen is expelled from a needle with pushing the stylet into the needle. But use of the stylet during EUS-FNA is difficult and time consuming process. Injecting air was not recommended, because of spraying out uncontrollably, increasing risk of air artifact and specimen clotting. However, there is no further study which one is the appropriate, suction or no suction and pushing the stylet or injecting air until now.
The hypothesis and aim of the prospective randomized controlled trials are as follows:
First hypothesis: There was no difference in the adequacy, cellularity, bloodiness, contamination, air artifact in specimen obtained by each methods, suction or no suction and pushing the stylet or injecting air.
Aim #1 : To compare the adequacy, cellularity, bloodiness, contamination, air artifact in specimen obtained by each methods, suction or no suction and pushing the stylet or injecting air.
Second hypothesis: There was no difference in sensitivity, specificity, diagnostic accuracy, positive predictive value, negative predictive value and statistical agreement in specimen obtained by each methods, suction or no suction and pushing the stylet or injecting air.
Aim #2 : To compare the sensitivity, specificity, diagnostic accuracy, positive predictive value, negative predictive value and statistical agreement in specimen obtained by each methods, suction or no suction and pushing the stylet or injecting air.
Conditions
- Pancreatic Neoplasm
- Neoplasm of Intra-abdominal Lymph Nodes
Interventions
- PROCEDURE
-
1.EUS-FNA with or without suction
During EUS-FNA of the peri-pancreatic mass was performed, with or without self-retracting 10-mL syringe applied.
- PROCEDURE
-
2.Pushing the stylet or injecting air
EUS-FNA specimen is expelled from a needle with pushing the stylet or injecting air into the needle
Sponsors & Collaborators
-
Samsung Medical Center
lead OTHER
Principal Investigators
-
Kwang Hyuck Lee, M.D. · Samsung Medical Center
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2010-09-30
- Primary Completion
- 2011-03-31
- Completion
- 2011-03-31
Countries
- South Korea
Study Locations
More Related Trials
-
A Randomized Controlled Trial Of Endoscopic Ultrasound-Guided Fine-Needle Aspiration With And Without A Stylet
NCT01213290 ·Status: UNKNOWN ·Phase: NA
-
Prospective Evaluation of Diagnostic Accuracy of Endoscopic Ultrasound-guided Fine Needle Aspiration and Biopsy (EUS-FNAB) in the Absence of Rapid Onsite Evaluation
NCT02079285 ·Status: COMPLETED
-
EUS-FNA of Solid Pancreatic Mass: Comparison Between Negative Pressure and Slow-pull Technique
NCT03111368 ·Status: COMPLETED ·Phase: NA
-
Comparison of EUS-Guided Fine Needle Aspiration Technique
NCT01923883 ·Status: UNKNOWN ·Phase: NA
-
Prospective Trial of EUS-FNA Versus EUS-FNB Using a Novel Core Biopsy Needle
NCT01769248 ·Status: COMPLETED ·Phase: NA
-
The Use of FNA and FNB in the Optimization of EUS-assisted Tissue Sampling
NCT02360839 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Efficacy Of 3 EUS-FNB Techniques
NCT05825729 ·Status: RECRUITING ·Phase: PHASE4
-
On-site Cytopathology EUS-FNA
NCT01386931 ·Status: COMPLETED
-
Comparing the Diagnostic Adequacy of 25-gauge Fork-tip, Franseen and Reverse-bevel Type Needles in Endoscopic Ultrasound Guided Tissue Acquisition
NCT05434247 ·Status: COMPLETED ·Phase: NA
-
Standard Versus Fanning Techniques for Endoscopic Ultrasound-Fine Needle Aspiration (EUS-FNA)
NCT01501903 ·Status: COMPLETED ·Phase: NA
-
Evaluation of EUS-Guided 22 Gauge Core Biopsy Versus Fine-needle Aspiration for Suspected Pancreatic Neoplasms
NCT01673334 ·Status: COMPLETED ·Phase: PHASE4
-
Prospective Multi-center, Single Blinded, Randomized, Controlled Trial of EUS-FNB and EUS-FNA on Solid Occupying Lesion
NCT02327065 ·Status: UNKNOWN ·Phase: NA
-
Diagnostic Accuracy of SurePath™ in EUS-FNA
NCT05394129 ·Status: TERMINATED
-
Yield of Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) With and Without the Use of a Stylet in the Biopsy Needle
NCT01241799 ·Status: COMPLETED ·Phase: NA
-
Is One Pass Enough for the Diagnosis of the Pancreatic Masses During EUS-FNB?
NCT05436704 ·Status: UNKNOWN
-
Prospective Study FNB, Is It Time To Abandon Cytological Assessment
NCT04165018 ·Status: COMPLETED
-
Comparing a 25G EUS Fine Needle Aspiration (FNA) Device With a 20G EUS
NCT02167074 ·Status: COMPLETED ·Phase: NA
-
Comparision of EUS-FNB Techniques for Diagnose of Solid Pancreatic Lesions
NCT05549856 ·Status: UNKNOWN ·Phase: NA
-
EUS-guided Fine Needle Biopsy With a New Core Histology Needle Versus Conventional Fine Needle Aspiration
NCT01774162 ·Status: COMPLETED ·Phase: NA
-
Efficiency Study of the EUS-FNA Needles With and Without a Side Port in Pancreatic Masses
NCT01978808 ·Status: UNKNOWN
-
A Multi-center, Prospective, Single-blind, Controlled Trial Comparing Diagnostic Value of Different EUS-FNA Techniques
NCT03674710 ·Status: UNKNOWN ·Phase: NA
-
Impact of Suction in the EUS-guided Fine Needle Biopsy of Solid Pancreatic Lesions
NCT04164017 ·Status: UNKNOWN ·Phase: NA
-
Modified Wet Suction Versus Capillary Techniques for EUS Guided Fine Needle Aspiration and Biopsy of Solid Lesions
NCT02919553 ·Status: WITHDRAWN ·Phase: NA
-
EUS-FNA for Patients With Antithrombotic Agents
NCT01798654 ·Status: COMPLETED
-
Clinical Evaluation of EUS-FNA on Diagnosis of Pancreatic Cystic Lesions
NCT02041897 ·Status: UNKNOWN ·Phase: NA