Pulse Pressure Variations as Index of Preload Dependency During Thoracic Surgery
NCT01329146 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 17
Last updated 2016-05-13
Summary
Background: calculation of the pulse pressure variation (PPV) has repeatedly been shown to be a reliable predictor of fluid responsiveness in mechanically ventilated patients. But PPV measurement has not been yet validated in thoracic surgery during one-lung ventilation. The modifications of intrathoracic pressure induced by one-lung ventilation may altered the capabilities of PPV to predict fluid responsiveness.This study was designed to assess the ability of PPV predict fluid responsiveness during one-lung ventilation in thoracic surgery.
Methods: a prospective observational study. Thirty five patients undergoing a pulmonary resection (lobectomy or pneumonectomy) will be included to achieve around one hundred fluid challenges with a 250 milliliters colloid solution in response to hemodynamic instability.Hemodynamic instability is defined as a decrease by 20 % of artery pressure from baseline and/or an increase by 20% heart rate from baseline. Fluid responsiveness is defined as an increase in stroke volume index (SVI)\>10% (measured with oesophageal doppler). PPV will be calculated from recorded artery pressure curve (PPVref) before and after each fluid challenge. An automated measurement of PPV proposed by the monitor Intelview (Philips) will be recorded simultaneously before and after each fluid challenge.
Statistical analysis: receiver operating characteristic curve will be used to assess the PPV capability to predict fluid responsiveness. Correlation analysis will be achieved using a Pearson test or Spearman's rho test when necessary. Continuous data will compared using a Student t test or a Mann-Whitney test when necessary.
Conditions
- Fluid Response
Sponsors & Collaborators
-
University Hospital, Lille
lead OTHER
Principal Investigators
-
Emmanuel ROBIN, MD PhD · Reanimation Department, University Hospital of Lille
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2008-10-31
- Primary Completion
- 2009-06-30
- Completion
- 2009-06-30
Countries
- France
Study Locations
More Related Trials
-
GDT-PPV Protocol in Thoracic Surgery
NCT04865874 ·Status: UNKNOWN ·Phase: NA
-
Value of Pulse Pressure Variations and Corrected Flow Time in Esophageal Doppler as a Predictor of Fluid Responsiveness in Prone Position During Spinal Surgery
NCT01646359 ·Status: COMPLETED ·Phase: NA
-
A Functional Test to Assess Fluid Status During Lung Protective Ventilation Strategies
NCT04118244 ·Status: COMPLETED
-
Factors Influencing of Pulse Pressure Variation (PPV)
NCT04802668 ·Status: COMPLETED
-
Peripheral Venous Pressure Variation, Pulse Pressure Variation and Pleth Variability Index for Fluid Responsiveness
NCT06733389 ·Status: NOT_YET_RECRUITING
-
Comparison of PPV and LVOT VTI During Passive Leg Raising to Predict Fluid Responsiveness
NCT07304661 ·Status: NOT_YET_RECRUITING
-
Open Lung PEEP in Thoracic Surgery
NCT03184974 ·Status: COMPLETED
-
Nondependent Lung Ventilation and Fluid Responsiveness
NCT02191410 ·Status: UNKNOWN ·Phase: PHASE3
-
Pulse Pressure Variation Helps to Predict Fluid Responsiveness in Patients Ventilated With Low Tidal Volumes
NCT01569308 ·Status: COMPLETED
-
Transpulmonary Pressure Under Stressing Conditions
NCT03746236 ·Status: UNKNOWN
-
Use of Heart-lung Interaction to Predict Haemodynamic Tolerance to the Open Lung Approach With Individualised PEEP
NCT06123039 ·Status: COMPLETED
-
Assessment of Preload Dependency Via Measurement of Peripheral Venous Pressure During an Alveolar Recruitment Manoeuvre
NCT05026255 ·Status: TERMINATED ·Phase: NA
-
Deep Learning Model for Predicting a Peripheral Venous Waveform-based Pulse Pressure Variation
NCT06734650 ·Status: NOT_YET_RECRUITING
-
Effects of Inspiratory Flow Waveforms on Preload
NCT01892696 ·Status: COMPLETED ·Phase: NA
-
An Assessment of Pulse Pressure Variation to Guide Fluid Therapy in Cardiac Surgery Patients
NCT01681758 ·Status: COMPLETED ·Phase: PHASE2
-
Variations of the Lung Compliance During Extracorporeal Circulation and Post Operative Pulmonary Complications
NCT02654600 ·Status: COMPLETED
-
Intra-abdominal Pressure and Dynamic Preload Variables
NCT02690688 ·Status: UNKNOWN
-
Role of Pulmonary Perfusion on Tolerance to Supine Position in Patients With ARDS
NCT05408442 ·Status: COMPLETED
-
Pressure-Controlled vs Volume-Controlled Ventilation During One Lung Ventilation
NCT00975468 ·Status: SUSPENDED ·Phase: NA
-
Comparison Between CPAP and HFJV During One-lung Ventilation in VATS
NCT03296449 ·Status: COMPLETED ·Phase: NA
-
Assessment of Preload Responsiveness in ARDS Patients During Prone Position
NCT04457739 ·Status: COMPLETED
-
Role of End-Tidal CO2 During Passive Leg Raising to Predict Fluid Responsiveness in ICU
NCT07304648 ·Status: NOT_YET_RECRUITING
-
Cardiopulmonary Changes Prolonged Surgical Abdominal Retractors Application in Supine Versus Lateral Position
NCT03776292 ·Status: COMPLETED
-
Stroke Volume Variations and Pulse Pressure Variations Undergoing Artificial Pneumothorax Surgery
NCT05644405 ·Status: COMPLETED ·Phase: NA
-
LIght Sedation Pressure Support
NCT03783468 ·Status: WITHDRAWN ·Phase: NA