Effectiveness of Stiffening Wire in Colonoscopy With Pre-Owned Colonoscopes

NCT01115010 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 112

Last updated 2011-08-03

No results posted yet for this study

Summary

The study aims to determine whether a proprietary, FDA approved stiffening wire improves the efficiency of colonoscopy (that is, decreases the duration of the procedure) and/or enables complete visualization of the colon in a greater proportion of cases (than when the procedure is performed without it) with old, used colonoscopes.

Colonoscopes are designed with a delicate balance between stiffness and flexibility. Stiffness helps to prevent curling (looping) of the colonoscope in those sections of the colon that are not fixed to the wall of the abdominal cavity and flexibility enables successful negotiation of bends or flexures in the colon. As colonoscopes age, they lose stiffness and this makes it very challenging to advance the colonoscope all the way to the cecum (the upper end of the colon). Even when the cecum is successfully reached, it may take an inordinately long time.

In Jamaica, most endoscopists (General Surgeons and Gastroenterologists) use older, pre-owned colonoscopes imported from the USA, because the average patient and local health insurance companies cannot bear the level of fees that would enable cost recovery for new equipment.

The stiffening wires (in two grades of stiffness) used in this study are passed through the biopsy channel of the colonoscope only after its tip has passed the upper end of the descending colon and entered the transverse colon. The device is safe when used as recommended by the manufacturers (and approved by the FDA), and does not appear to increase risk over and above the risk of colonoscopy with the unassisted colonoscope. Although the device clearly improves the stiffness of the colonoscope, there is no research evidence that it actually works in practice, either to improve cecal intubation rate or to decrease procedure time. It is therefore also unclear whether the possible benefit of using the device is achieved if introduced at the first opportunity allowed by the manufacturers or only after difficulty is encountered with the unassisted colonoscope.

In this study, patients are randomly assigned to one of 3 "interventions". One group has colonoscopy performed with the colonoscope alone and the wires are only introduced if there is difficulty advancing the colonoscope after it has passed into the transverse colon ("difficulty" defined as failure to advance the tip of the colonoscope after 5 minutes). In the 2nd and 3rd groups, the assigned wire will be introduced as soon as the colonoscope enters the transverse colon and is removed if "difficulty" is encountered, as defined above. The different phases of colonoscopy will be timed with a stop watch and when a sufficient number of patients has been accrued, the investigator will be able to compare the time it takes to complete the procedure with and without the wires as well as the proportion of cases in which the cecum was reached with and without the assistance of the wires.

Conditions

  • Colonoscopy

Interventions

DEVICE

Colonoscope stiffening device

Colonoscopy is performed with the unassisted colonoscope (Olympus CF-100TL). The "standard" stiffening wire is introduced only if there is difficulty advancing the colonoscope and only after the tip has passed the splenic flexure. Difficulty is defined as failure to advance the tip of the scope after 5 minutes of trying. If difficulty is again encountered, the "firm" wire replaces the "standard" wire. Further difficulty requires removal of the firm wire and so on until cecal intubation is achieved or the procedure is abandoned.

DEVICE

Colonoscope stiffening device

"Standard" stiffening wire introduced routinely on entry into transverse colon. If difficulty is encountered (as defined previously), the "standard" wire is removed and attempts made to advance the colonoscope without it. Further difficulty requires introduction of the "firm" wire and so on until cecal intubation is achieved or the procedure is abandoned.

DEVICE

Colonoscope stiffening device

"Firm" stiffening wire introduced routinely on entry into transverse colon. If difficulty is encountered (as defined previously), the wire is removed and attempts made to advance the colonoscope without it. Further difficulty requires introduction of the "standard" wire and so on until cecal intubation is achieved or the procedure is abandoned.

Sponsors & Collaborators

  • MoBay Hope Medical Center, Jamaica

    collaborator OTHER
  • Cornwall Regional Hospital

    lead OTHER_GOV

Principal Investigators

  • Jeffrey M East, MD · Cornwall Regional Hospital

Study Design

Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2009-12-31
Primary Completion
2011-01-31
Completion
2011-01-31

Countries

  • Jamaica

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01115010 on ClinicalTrials.gov