U Clip Study - Study to Compare U Clip Anastomosis With Conventional Continuous Prolene Anastomosis
NCT00829153 · Status: UNKNOWN · Phase: PHASE1/PHASE2 · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2010-03-16
Summary
The requirements for haemodialysis are increasing. There is now acceptance that the most durable AV fistulae are those created from the patients own veins. Use of the radiocephalic arteriovenous fistula as an autologous vascular access dates back to the 1960's. (Brescia MJ, Cimino JE. Appel K, Hurwich BJ. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 1966; 275: 1089 - 1092.) Once established, it has good long term survival and a low complication rate. However, the success rate at creation of a useable AV fistula are not good. In a meta-analysis published in 2005, the primary failure rate of a radiocephalic fistula was 15.3% and the primary and secondary patency rates were 62.5% and 66.0% at one year. (Rooijens PPGM, Tordoir JHM, Stijnen T, Burgmans JPJ, Smet AAEA and Yo TI. Radiocephalic wrist arteriovenous fistula for hemodialysis: meta-analysis indicates a high primary failure rate. Eur J Vasc Endovasc Surg 2004; 28, 583-589). Reasons for this are multiple but it appears as though the main determinants are the quality of the patients veins and the technical skill of the surgeon. Low patency rates are also seen in females and those with small veins and arteries. Creating an anastomosis between a small vein and artery is technically challenging. This is traditionally preformed with a continuous prolene suture. Recently, Medtronic have been marketing the U Clip Anastomotic Device. This is a self closing devise which could be called a vascular clip. Reported advantages of this clip include better patency rates and faster operations. However, to our knowledge there is no randomised evidence to support this with regards to AV fistulas.
The vascular anastomosis originally developed by Alexis Carrel used interrupted sutures. Over time this was replaced by a continuous suture technique which was felt to be quicker and had similar patency rates. However, microvascular, paediatric and neurovascular surgeons have shown that there are advantages to an interrupted technique. (Hattori H, Killen DA, Green JW. Influence of suture material and technic on patency of anastomosed arteries of less than 1.5mm. Am Surg. 1970; 36: 352 - 354. Cobbett JR. Microvascular surgery. Surg Clin N Am. 1962; 47: 521.). The reasons for the improved patency with interrupted anastomoses are firstly increased anastomotic compliance and flow rate and secondly elimination of the pursestring effect and puckering seen with continuous sutures.
In a prospective but non randomised study to compare interrupted U clips with historical published results, the patency rate of coronary anastomoses was 100% at 6 months using the U clips compare to a patency rate of 90 -100% in the published series. (Wolf RK, Alderman EL, Caskey MP et al. Clinical and six month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self closing clip device: a multicentre prospective clinical trial. J Thorac cardiovasc Surg 2003; 126(1): 168 - 178.)
Reports from single centres have concluded that the U Clips offer the opportunity to create superior interrupted anastomoses for AV fistula, even in patients who would otherwise be considered poor candidates for fistula creation. (Ross JR. Creation of native arteriovenous fistulas with interrupted anastomoses using a self closing clip device - one clinics experience. Journal of vascular Access 2002; 3: 140 - 146). In this report with small numbers, the radiocephalic fistulas had an 8 week maturation rate of 93%. Of the 28 patients having a radiocephalic fistula, 10 had veins of between 1.0 - 1,5mm diameter.
The aim of this pilot study will be to assess if there is a clinical difference in the maturation rates of autologous AV fistulae when a clipped anastomosis is compared to a conventional prolene anastomosis.
Conditions
- Haemodialysis
Interventions
- DEVICE
-
U Clip
Interuppted nitional clips
- PROCEDURE
-
Conventional prolene anastomosis
Continuous prolene anastomosis
Sponsors & Collaborators
-
Royal Hobart Hospital
lead OTHER_GOV
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2007-01-31
- Primary Completion
- 2010-08-31
Countries
- Australia
Study Locations
More Related Trials
-
Ultrasound to Predict Steal-Syndrome After Arteriovenous-Fistula Creation (UPSAC - Trial)
NCT01468506 ·Status: WITHDRAWN
-
A Trial of Interrupted vs Continuous Suturing Techniques for Radiocephalic Fistulae
NCT01704313 ·Status: UNKNOWN ·Phase: NA
-
Optimal Screening Program in Detecting Stenosis and Predicting Thrombosis in Hemodialysis Graft
NCT03839264 ·Status: COMPLETED
-
Comparison of Three Types of Distal Arteriovenous Fistulas: SBAVF, RCAVF, and RCAVF With Venous Branch Patch.
NCT06550479 ·Status: RECRUITING ·Phase: NA
-
Maximizing Native Arteriovenous Fistulae Rates.
NCT02705417 ·Status: COMPLETED
-
Relationship Between Arterial Variations and Patency of Arteriovenous Fistulae
NCT04613115 ·Status: COMPLETED
-
Optimizing Access Surgery In Senior Hemodialysis Patients
NCT05911451 ·Status: COMPLETED ·Phase: NA
-
Vein Histology in Arteriovenous Fistulas and Its Effect on Fistula Surgery Success
NCT01099189 ·Status: COMPLETED
-
Trial Comparing the Incidence of Steal Syndrome in the Two Types of anTEcubitaL Fossa Arteriovenous fistuLa AVF
NCT02297451 ·Status: COMPLETED ·Phase: NA
-
The Arteriovenous Vascular (AV) ACCESS Trial
NCT04646226 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Ultrasound Assisted Puncture of AV Fistulas in Chronic Hemodialysis Patients
NCT02085486 ·Status: WITHDRAWN ·Phase: NA
-
Anchor Versus Parachute Suturing Technique in Arteriovenous Fistula Creation for Hemodialysis
NCT06091839 ·Status: COMPLETED ·Phase: NA
-
Randomized Fistula Study
NCT00808561 ·Status: TERMINATED ·Phase: NA
-
Hemodialysis Vascular Access Imaging Study
NCT02374762 ·Status: COMPLETED
-
The Outcomes of Arteriovenous Fistula Cannulated From Different Direction.
NCT01642459 ·Status: TERMINATED ·Phase: NA
-
Arteriovenous Fistula Cannulation Practices and Dialysis Adequacy
NCT04270292 ·Status: COMPLETED
-
Colour Coded Duplex Ultrasound of Native Arterio-venous Fistula for Haemodialysis With Venous Pressure Measurement Using Controlled Compression Ultrasound as a Predictor for Shunt Maturation in the Early Postoperative Phase
NCT01001000 ·Status: UNKNOWN
-
Prefistula Forearm Exercise in Pts Requiring Chronic HD Therapy
NCT03988270 ·Status: COMPLETED ·Phase: NA
-
Clipped Versus Handsewn Arteriovenous Fistula Anastomosis
NCT01669850 ·Status: TERMINATED ·Phase: NA
-
av Fistula Patency Loss as a Cause of Fistula Failure and Hyperphosphatemia
NCT05569109 ·Status: UNKNOWN
-
ENhancing Maturation of Autogenous Arteriovenous Hemodialysis Access by Aggressive surveillaNCe With Duplex and Endovascular Treatment
NCT01597115 ·Status: COMPLETED ·Phase: NA
-
Optimal Timing of Percutaneous Intervention in Non-maturing Dialysis Fistulas
NCT03245944 ·Status: COMPLETED ·Phase: NA
-
Isometric Preoperative Exercise on Autologous Arteriovenous Fistulas. Randomized Clinical Trial
NCT03213756 ·Status: COMPLETED ·Phase: NA
-
Local Anaesthesia vs Regional Block for Arteriovenous Fistulae
NCT01706354 ·Status: UNKNOWN ·Phase: NA
-
Contrast Ultrasound in the Surveillance of Endovascular Abdominal Aortic Aneurysm Repair
NCT01022892 ·Status: COMPLETED