Choice of Material for Above-Knee Femoro-Popliteal Bypass Prosthetic Graft (PopUp)
NCT00300690 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 400
Last updated 2006-03-09
Summary
This trial was designed to challenge the wide held view that polytetrafluoroethylene (PTFE) performs better than Dacron for above knee femoropopliteal bypass.
Conditions
- Intermittent Claudication
- Critical Limb Ischemia
Interventions
- DEVICE
-
6 mm Uni-graft® (B-Braun)
- DEVICE
-
6 mm Gore-Tex® (WL Gore)
Sponsors & Collaborators
-
B. Braun Melsungen AG
collaborator INDUSTRY -
University Hospital, Gentofte, Copenhagen
lead OTHER
Principal Investigators
-
Torben V Schroeder, Professor · Rigshospitalet, Denmark
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 1993-10-31
- Completion
- 1999-01-31
More Related Trials
-
Highly Cross-linked Polyethylene in Total Knee Arthroplasty
NCT03622398 ·Status: COMPLETED ·Phase: PHASE4
-
Long-term Evaluation Protocol (12 Months Postoperative) of Total Knee Prostheses Anatomic With Resurfaced Patella Versus Non-resurfaced Patella in Patients Requiring Total Knee Arthroplasty
NCT03081260 ·Status: COMPLETED ·Phase: NA
-
Cemented Versus Uncemented Total Knee Arthroplasty : a Prospective Randomized Study
NCT02355652 ·Status: WITHDRAWN ·Phase: PHASE4
-
Cemented vs. Cementless TKA
NCT04597684 ·Status: TERMINATED ·Phase: NA
-
Comparison of Mobile-Bearing and Fixed-Bearing All-Polyethylene Tibia Total Knee Designs
NCT00894361 ·Status: TERMINATED ·Phase: PHASE4
-
Observational Study to Evaluate Clinical Performance and Safety in Total Knee Arthroplasty
NCT04872855 ·Status: TERMINATED
-
Outcome Study of Highly-cross Linked Polyethylene vs. Standard Polyethylene for Primary Posterior Stabilized (PS) Total Knee
NCT02178020 ·Status: UNKNOWN
-
Long-Term Comparison of Fixed- and Mobile-Bearing Total Knee Arthroplasties (TKAs) in Patients With OA ≤50 Years Old
NCT01361152 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of High Flex and Standard Rotating Platform Total Knee Arthroplasty (TKA)
NCT01176292 ·Status: COMPLETED ·Phase: NA
-
Lubinus SPII Hip Stem Target Trial Emulation
NCT06367829 ·Status: ENROLLING_BY_INVITATION
-
Stability of Contemporary Knee Arthroplasty
NCT02861794 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Standard and Robot Assisted Total Knee Arthroplasty with a Bicrucatie Retaining Prosthesis
NCT04334304 ·Status: TERMINATED ·Phase: NA
-
All Polyethylene Versus Metal Backed Tibial Components in Knee Replacement
NCT02482493 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Total Knee Arthroplasty (TKA) Cemented Versus Cementless
NCT00132587 ·Status: COMPLETED ·Phase: NA
-
A Randomised Single Centre Study to Compare the Long-term Performance of 4 Designs of the DePuy Ultima LX Stem in Primary Total Hip Replacement
NCT00208351 ·Status: TERMINATED ·Phase: PHASE3
-
A Comparison of the Design of Tibia Stems in Cemented Total Knee Arthroplasty - Wedge Stem Versus I-beam Stem.
NCT00175136 ·Status: COMPLETED ·Phase: NA
-
Use of Passive, Adaptive, and Active Prosthetic Knees in Persons With Unilateral, Transfemoral Amputation
NCT02219230 ·Status: COMPLETED ·Phase: NA
-
Comparison of Stability and Outcomes in Single-radius Femoral Component for Total Knee Arthroplasty
NCT01379755 ·Status: UNKNOWN
-
Comparison Of Outcomes After Knee Arthroplasty Using Posterior-Substituting Versus Cruciate-Retaining Prostheses
NCT06170931 ·Status: COMPLETED ·Phase: NA
-
Trial Comparing Navigated and Conventional Implantation Techniques in Knee Replacement Surgery
NCT00431509 ·Status: UNKNOWN ·Phase: PHASE4
-
Minimally Invasive Versus Conventional Approaches in Navigated Total Knee Arthroplasty (TKA)
NCT00839020 ·Status: TERMINATED ·Phase: PHASE4
-
Bone Remodeling Around a Trabecular Titanium Cup in Total Hip Arthroplasty
NCT06287021 ·Status: RECRUITING ·Phase: NA
-
Comparing Fixed-bearing Versus Mobile-bearing Prosthesis in Total Knee Arthroplasty: A Prospective Randomized Trial
NCT01312532 ·Status: COMPLETED ·Phase: PHASE2
-
A Comparison of Two Surface Materials (Tantalum Versus Titanium Fiber Mesh) of Acetabular Components in Hip Arthroplasty
NCT00116051 ·Status: COMPLETED ·Phase: NA
-
Clinical and Radiological Impact of Tibial Cutting Int Total Knee Arthroplasty, Accelerated Navigation Versus Extramedullary Targeting
NCT03951545 ·Status: UNKNOWN ·Phase: NA