AI-Guided Predictions of Blood Pressure Dysregulation Using Perfusion Index as a Novel Biomarker in Persons With Spinal Cord Injury
NCT07699094 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 24
Last updated 2026-08-10
Summary
The goal of this clinical trial is to determine if perfusion index (PI) can reliably predict changes in systolic blood pressure (SBP) in persons with spinal cord injury (SCI) during a cool temperature challenge. Participants with SCI can be 18-75 years of age, male or female, neurological level of injury C4-T12, ASIA Impairment Scale (AIS: A or B: motor complete) or gender and healthy age-matched able-bodied (AB) controls.
The main question this study aims to answer is: can PI reliably predict change in SBP during a cool temperature challenge? The investigators hypothesize that PI can be used as a biomarker of SBP in persons with SCI.
Researchers will compare the relationship of 1) changes in PI and SBP and 2) relationship of changes in other vital signs to SBP, during the cool temperature challenge. The researchers aim to determine if PI can be used as a biomarker of SBP in persons with SCI during a cool temperature challenge (experimental group/arm). Able-bodied controls (control group/arm) will receive the same intervention (cool challenge) as the experimental group.
During the study, participants will be asked to wear only shorts and a T-shirt so that their skin can be exposed to the warm and cool temperatures of the 2 rooms.
The investigators will put put on non-invasive sensors (taped or attached on the surface of your body) to measure PI, BP, and other vital signs. The investigators will record these measurements while the participant is seated in a wheelchair for 10 minutes in a warm room and up to 90 minutes in a cool room.
Conditions
- Spinal Cord Injuries (SCI)
- Blood Pressure
- Thermoregulation
- Perfusion Index
Interventions
- OTHER
-
Controlled Cool Thermal Challenge (18°C)
Participants with SCI will undergo a controlled, non-invasive cool thermal challenge of 18°C (64.4°F) in a climate-controlled chamber for up to 90 minutes. Participants will remain seated in their wheelchair while wearing a standard T-shirt and shorts to ensure uniform skin exposure. Continuous non-invasive monitoring of perfusion index and blood pressure will be performed throughout the baseline of 27°C (80°F) and cool challenge 18°C (64.4°F) phases to evaluate their relationship.
- OTHER
-
Controlled Cool Thermal Challenge (18°C)
Able-bodied participants will undergo a controlled, non-invasive cool thermal challenge of 18°C (64.4°F) in a climate-controlled chamber for up to 90 minutes. Participants will remain seated in a wheelchair that will be provided while wearing a standard T-shirt and shorts to ensure uniform skin exposure. Continuous non-invasive monitoring of perfusion index and blood pressure will be performed throughout the baseline of 27°C (80°F) and cool challenge 18°C (64.4°F) phases to evaluate their relationship.
Sponsors & Collaborators
-
James J. Peters Veterans Affairs Medical Center
lead FED
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-09-01
- Primary Completion
- 2028-06-30
- Completion
- 2028-06-30
Countries
- United States
Study Locations
More Related Trials
-
Non-invasive Intracranial Pressure Monitoring to Improve Emergency Care in Brazil's Public Health System
NCT07210333 ·Status: NOT_YET_RECRUITING
-
Peripheral Perfusion Index as a Predictor of Post-spinal Hypotension in Patients Undergoing Lower Limb Surgeries
NCT07279805 ·Status: COMPLETED
-
Safety, Feasibility, and Efficacy of TSCS on Stabilizing Blood Pressure for Acute Inpatients With SCI
NCT06000592 ·Status: RECRUITING ·Phase: NA
-
Non-invasive Versus Invasive Blood Pressure Measurement in the Morbidly Obese Parturient With Severe Preeclampsia
NCT03222414 ·Status: TERMINATED ·Phase: NA
-
Cerebral Pulsatility Index Compared To Mean Arterial Blood Pressure Guided Protocol In Sepsis Induced Encephalopathy:
NCT05842616 ·Status: COMPLETED ·Phase: NA
-
A Novel Non-invasive Technique of Cerebral Compliance and Auto-regulation Assessment
NCT03144219 ·Status: UNKNOWN
-
Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03046264 ·Status: COMPLETED
-
Cerebral Perfusion Variation During Blood Pressure Changes in ICU
NCT05804773 ·Status: RECRUITING
-
Physiological Validation of Current Machine Learning Models for Hemodynamic Instability in Humans
NCT03927066 ·Status: COMPLETED ·Phase: NA
-
Brain Skull Deformation as a Non-invasive Intracranial Pressure (ICP) Measure
NCT05121155 ·Status: COMPLETED
-
Arterial Pulse Waveform Contour Analysis for Intraoperative Goal Directed Therapy in Major Spine Surgery
NCT01124474 ·Status: TERMINATED ·Phase: NA
-
Validation of Non-Invasive Intracranial Pressure (ICP) Monitoring Device
NCT03865576 ·Status: UNKNOWN
-
Evaluation and Calibration of a Novel Non-invasive Wearable Device for Monitoring Vital Signs
NCT04081987 ·Status: UNKNOWN
-
Evaluation of Continuous Non Invasive Blood Pressure With Adult Volunteers
NCT04876664 ·Status: UNKNOWN ·Phase: NA
-
Feasibility of Home Telehealth Monitoring for Improvement in Management of Hypertension for Secondary Stroke Prevention
NCT03517709 ·Status: WITHDRAWN ·Phase: NA
-
Non-invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03049709 ·Status: COMPLETED
-
Personal BP - CAI Study
NCT06492746 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Zero Heat Flux Cutaneous Temperature in Intensive Care Adults
NCT02931227 ·Status: COMPLETED ·Phase: NA
-
"AI-Based Noninvasive Blood Pressure Monitoring Compared to Invasive Arterial Measurement"
NCT06915376 ·Status: COMPLETED
-
Assessment of Flow in Cerebrospinal Fluid Shunts With a Second Generation Wireless Thermal Anisotropy Measurement Device
NCT06409286 ·Status: NOT_YET_RECRUITING
-
Brain PERfusion Evaluation by Contrast-Enhanced UltraSound
NCT05893407 ·Status: RECRUITING
-
Assessment of CSF Shunt Flow During Activities of Daily Living and Sleep With a Thermal Measurement Device
NCT07050628 ·Status: RECRUITING ·Phase: NA
-
Office Blood Pressure Measurement With an Automated Device
NCT03460249 ·Status: COMPLETED ·Phase: NA
-
Long Pressure Autoregulation Index
NCT05043545 ·Status: COMPLETED
-
Assessment of Peripheral Perfusion in the Critically Ill Patient
NCT02771002 ·Status: COMPLETED