Brain Skull Deformation as a Non-invasive Intracranial Pressure (ICP) Measure

NCT05121155 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 18

Last updated 2021-11-16

No results posted yet for this study

Summary

Background: Although placement of an intra-cerebral catheter remains the gold standard method for measuring intracranial pressure (ICP), there are several limitations to the method. Objectives: The main objective of this study was to compare the correlation and the agreement of the wave morphology between the ICP (standard ICP monitoring) and a new nICP monitor in patients admitted with stroke. Our secondary objective was to estimate the accuracy of four non-invasive methods to assess intracranial hypertension. Methods: We prospectively collected data of adults admitted to an intensive care unit (ICU) with subarachnoid hemorrhage (SAH), intracerebral hemorrhage (ICH) or ischemic stroke (IS) in whom invasive ICP monitoring placed. Measures had been simultaneously collected from the following non-invasive indices: optic nerve sheath diameter (ONSD), pulsatility index (PI) using transcranial Doppler (TCD), a 5-point visual scale designed for Computed Tomography (CT) and two parameters (time-to-peak \[TTP\] and P2/P1 ratio) of a non-invasive ICP wave morphology monitor (Brain4care\[B4c\]). Intracranial hypertension was defined as an invasively measured ICP \> 20 mmHg for at least five minutes.

Conditions

  • Subarachnoid Hemorrhage
  • Stroke
  • Stroke, Ischemic
  • Stroke Hemorrhagic
  • Intracranial Hypertension

Interventions

DEVICE

ICP wave morphology comparison between a non-invasive (Brain4care) and a invasive method

We prospectively collected data of adults admitted to an intensive care unit (ICU) with subarachnoid hemorrhage (SAH), intracerebral hemorrhage (ICH) or ischemic stroke (IS) in whom invasive ICP monitoring placed. Measures had been simultaneously collected from the following non-invasive indices: optic nerve sheath diameter (ONSD), pulsatility index (PI) using transcranial Doppler (TCD), a 5-point visual scale designed for Computed Tomography (CT) and two parameters (time-to-peak \[TTP\] and P2/P1 ratio) of a non-invasive ICP wave morphology monitor (Brain4care\[B4c\]). Intracranial hypertension was defined as an invasively measured ICP \> 20 mmHg for at least five minutes

Sponsors & Collaborators

  • Federal University of São Paulo

    lead OTHER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-03-01
Primary Completion
2020-03-30
Completion
2020-03-30
FDA Device
Yes

Countries

  • Brazil

Study Locations